Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.karry - Content
-
... ... @@ -19,8 +19,8 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 2~~ 2,000 μS/cm Resolution: 1 μS/cm23 -** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm22 +** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 26 ... ... @@ -41,7 +41,7 @@ 41 41 == 1.3 Wiring == 42 42 43 43 44 -[[image:image-2024 0720172533-1.png||height="347" width="569"]]44 +[[image:image-20241129142314-1.png]] 45 45 46 46 47 47 == 1.4 Mechinical Drawing == ... ... @@ -641,7 +641,6 @@ 641 641 0XC3 642 642 ))) 643 643 644 - 645 645 = 4. DR-DO1 Dissolved Oxygen Sensor = 646 646 647 647 == 4.1 Specification == ... ... @@ -672,9 +672,10 @@ 672 672 == 4.3 Impedance requirements for current signals == 673 673 674 674 675 -[[image:image-20240718195414-8.png||height="100" width="575"]] 674 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %) 675 +|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 676 +|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 676 676 677 - 678 678 == 4.4 Mechinical Drawing == 679 679 680 680 ... ... @@ -773,7 +773,7 @@ 773 773 == 5.1 Specification == 774 774 775 775 776 -* **Measuring range**: 0.11000.0NTU 776 +* **Measuring range**: 0.1~~1000.0NTU 777 777 778 778 * **Accuracy**: ±5% 779 779 ... ... @@ -781,9 +781,9 @@ 781 781 782 782 * **Stability**: ≤3mV/24 hours 783 783 784 -* **Output signal**: A: 420 mA (current loop)B:RS485 (standard Modbus-RTU protocol, device default address: 01)784 +* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 785 785 786 -* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 786 +* **Power supply voltage**: 524V DC (when output signal is RS485)12-24V DC (when output signal is 420mA) 787 787 788 788 * **Working environment**: temperature 060°C; humidity ≤ 95%RH 789 789 ... ... @@ -798,11 +798,10 @@ 798 798 == 5.3 Impedance requirements for current signals == 799 799 800 800 801 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:4 20px" %)802 -| =(% style="width:40px" %)Supply Voltage|=(% style="width:0px;" %)9V|=(% style="width:0px;" %)**12V**|=(% style="width:0px;" %)**20V**|=(% style="width:0px;" %)**24V**803 -|(% style="width:13 7px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω**801 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %) 802 +|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 803 +|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 804 804 805 - 806 806 == 5.4 Mechinical Drawing == 807 807 808 808 ... ... @@ -875,3 +875,9 @@ 875 875 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 876 876 877 877 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 877 + 878 + 879 += 6. Water Quality Sensor Datasheet = 880 + 881 + 882 +* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.2 MB - Content