Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -32,6 +32,7 @@ 32 32 33 33 * **Max Pressure**: 0.6MPa 34 34 35 + 35 35 == 1.2 Application for Different Range == 36 36 37 37 ... ... @@ -99,6 +99,7 @@ 99 99 100 100 * The equipment should be calibrated before each use. It is recommended to calibrate it every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). 101 101 103 + 102 102 == 1.7 RS485 Commands == 103 103 104 104 ... ... @@ -124,6 +124,7 @@ 124 124 |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 125 125 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 126 126 129 + 127 127 === 1.7.2 Change address === 128 128 129 129 ... ... @@ -161,6 +161,7 @@ 161 161 0X8F 162 162 ))) 163 163 167 + 164 164 === 1.7.4 Query data === 165 165 166 166 ... ... @@ -247,6 +247,7 @@ 247 247 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 high 248 248 |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50 249 249 254 + 250 250 = 2. DR-PH01 Water PH Sensor = 251 251 252 252 == 2.1 Specification == ... ... @@ -276,6 +276,7 @@ 276 276 277 277 * **Max Pressure**: 0.6MPa 278 278 284 + 279 279 == 2.2 Wiring == 280 280 281 281 ... ... @@ -337,6 +337,7 @@ 337 337 338 338 * The equipment should be calibrated before each use. For long-term use, it is recommended to calibrate once every 3 months. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time. 339 339 346 + 340 340 == 2.6 RS485 Commands == 341 341 342 342 ... ... @@ -481,6 +481,7 @@ 481 481 482 482 * **Max Pressure**: 0.6MPa 483 483 491 + 484 484 == 3.2 Wiring == 485 485 486 486 ... ... @@ -551,6 +551,7 @@ 551 551 |=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 64.75px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 64.75px;background-color:#4F81BD;color:white" %)CRC16 high 552 552 |(% style="width:99px" %)0XFE |(% style="width:112px" %)0X03|(% style="width:135px" %)0X00|(% style="width:126px" %)0X50|(% style="width:85px" %)0X00|(% style="width:1px" %)0X00|(% style="width:1px" %)0X51|(% style="width:1px" %)0XD4 553 553 562 + 554 554 **response:** 555 555 556 556 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) ... ... @@ -557,6 +557,7 @@ 557 557 |=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 558 558 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 559 559 569 + 560 560 === 3.6.2 Change address === 561 561 562 562 ... ... @@ -594,6 +594,7 @@ 594 594 0X96 595 595 ))) 596 596 607 + 597 597 === 3.6.4 Query data === 598 598 599 599 ... ... @@ -641,7 +641,6 @@ 641 641 0XC3 642 642 ))) 643 643 644 - 645 645 = 4. DR-DO1 Dissolved Oxygen Sensor = 646 646 647 647 == 4.1 Specification == ... ... @@ -672,6 +672,10 @@ 672 672 == 4.3 Impedance requirements for current signals == 673 673 674 674 685 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 686 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 687 +|(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 688 + 675 675 [[image:image-20240718195414-8.png||height="100" width="575"]] 676 676 677 677 ... ... @@ -688,6 +688,7 @@ 688 688 689 689 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 690 690 705 + 691 691 == 4.6 RS485 Commands == 692 692 693 693 ... ... @@ -731,6 +731,7 @@ 731 731 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Register length low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 732 732 |(% style="width:99px" %)0X01|(% style="width:72px" %)0X10|(% style="width:64px" %)0X00|(% style="width:68px" %)0X0A|(% style="width:70px" %)0X00|(% style="width:72px" %)0X02|(% style="width:56px" %)0X61|(% style="width:56px" %)0XCA 733 733 749 + 734 734 === 4.6.3 Query data === 735 735 736 736 ... ... @@ -798,8 +798,8 @@ 798 798 == 5.3 Impedance requirements for current signals == 799 799 800 800 801 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:4 17px" %)802 -|=(% style="width: 1 37px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width:68px;" %)**12V**|=(% style="width:68px;" %)**20V**|=(% style="width: 70px;" %)**24V**817 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:420px" %) 818 +|=(% style="width: 140px" %)Supply Voltage|=(% style="width: 70px;" %)9V|=(% style="width: 70px;" %)**12V**|=(% style="width: 70px;" %)**20V**|=(% style="width: 70px;" %)**24V** 803 803 |(% style="width:137px" %)**Max Impedance**|(% style="width:70px" %)**<250Ω**|(% style="width:68px" %)**<400Ω**|(% style="width:68px" %)**<500Ω**|(% style="width:70px" %)**<900Ω** 804 804 805 805