From version < 45.92 >
edited by Xiaoling
on 2024/08/06 17:59
To version < 46.4 >
edited by Xiaoling
on 2024/08/07 09:10
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -557,6 +557,7 @@
557 557  |=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high
558 558  |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0
559 559  
560 +
560 560  === 3.6.2 Change address ===
561 561  
562 562  
... ... @@ -663,6 +663,7 @@
663 663  
664 664  * **Power consumption**: ≤0.5W
665 665  
667 +
666 666  == 4.2 wiring ==
667 667  
668 668  
... ... @@ -672,7 +672,9 @@
672 672  == 4.3 Impedance requirements for current signals ==
673 673  
674 674  
675 -[[image:image-20240718195414-8.png||height="100" width="575"]]
677 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %)
678 +|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
679 +|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
676 676  
677 677  
678 678  == 4.4 Mechinical Drawing ==
... ... @@ -688,6 +688,7 @@
688 688  
689 689  * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently.
690 690  
695 +
691 691  == 4.6 RS485 Commands ==
692 692  
693 693  
... ... @@ -789,6 +789,7 @@
789 789  
790 790  * **Power consumption**: ≤ 0.5W
791 791  
797 +
792 792  == 5.2 wiring ==
793 793  
794 794  
... ... @@ -798,9 +798,9 @@
798 798  == 5.3 Impedance requirements for current signals ==
799 799  
800 800  
801 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %)
802 -|=(% style="width: 128px; background-color: rgb(79, 129, 189); color: white;" %)Supply Voltage|=(% style="width: 82px" %)9V|=(% style="width: 103.6px" %)**12V**|=(% style="width: 103.6px" %)**20V**|=(% style="width: 103.6px" %)**24V**
803 -|(% style="background-color:#4f81bd; color:white; width:128px" %)Max Impedance|(% style="width:82px" %)<250Ω|(% style="width:106px" %)<400Ω|(% style="width:93px" %)<500Ω|(% style="width:104px" %)<900Ω
807 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %)
808 +|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V**
809 +|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω**
804 804  
805 805  
806 806  == 5.4 Mechinical Drawing ==
... ... @@ -816,6 +816,7 @@
816 816  
817 817  * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently.
818 818  
825 +
819 819  == 5.6 RS485 Commands ==
820 820  
821 821  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0