Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -481,7 +481,6 @@ 481 481 482 482 * **Max Pressure**: 0.6MPa 483 483 484 - 485 485 == 3.2 Wiring == 486 486 487 487 ... ... @@ -558,6 +558,7 @@ 558 558 |=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 559 559 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 560 560 560 + 561 561 === 3.6.2 Change address === 562 562 563 563 ... ... @@ -643,7 +643,6 @@ 643 643 ))) 644 644 645 645 646 - 647 647 = 4. DR-DO1 Dissolved Oxygen Sensor = 648 648 649 649 == 4.1 Specification == ... ... @@ -665,6 +665,7 @@ 665 665 666 666 * **Power consumption**: ≤0.5W 667 667 667 + 668 668 == 4.2 wiring == 669 669 670 670 ... ... @@ -674,7 +674,9 @@ 674 674 == 4.3 Impedance requirements for current signals == 675 675 676 676 677 -[[image:image-20240718195414-8.png||height="100" width="575"]] 677 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %) 678 +|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 679 +|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 678 678 679 679 680 680 == 4.4 Mechinical Drawing == ... ... @@ -690,6 +690,7 @@ 690 690 691 691 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 692 692 695 + 693 693 == 4.6 RS485 Commands == 694 694 695 695 ... ... @@ -791,6 +791,7 @@ 791 791 792 792 * **Power consumption**: ≤ 0.5W 793 793 797 + 794 794 == 5.2 wiring == 795 795 796 796 ... ... @@ -799,12 +799,10 @@ 799 799 800 800 == 5.3 Impedance requirements for current signals == 801 801 802 -供电电压 9V 12V 20V 24V 803 -最大阻抗 <250Ω <400Ω <500Ω <900Ω 804 804 805 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width: 518px" %)806 -| =(% style="width:03.6px;background-color:#4F81BD;color:white" %)Supply Voltage|=(% style="width:103.6px;background-color:#4F81BD;color:white" %)9V|=(% style="width:103.6px; background-color: rgb(79, 129, 189); color: white;" %)**12V**|=(% style="width:103.6px; background-color: rgb(79, 129, 189); color: white;" %)**20V**|=(% style="width:103.6px; background-color: rgb(79, 129, 189); color: white;" %)**24V**807 -|(% style="width: 99px" %)Max Impedance|(% style="width:112px" %)<250Ω|(% style="width:106px" %)<400Ω|(% style="width:93px" %)<500Ω|(% style="width:104px" %)<900Ω807 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %) 808 +|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 809 +|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 808 808 809 809 810 810 == 5.4 Mechinical Drawing == ... ... @@ -820,6 +820,7 @@ 820 820 821 821 * If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 822 822 825 + 823 823 == 5.6 RS485 Commands == 824 824 825 825