From version < 45.63 >
edited by Xiaoling
on 2024/08/06 14:47
To version < 45.62 >
edited by Xiaoling
on 2024/08/06 14:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,28 +11,19 @@
11 11  
12 12  
13 13  * **Power Input**: DC7~~30
14 -
15 15  * **Power Consumption** : < 0.5W
16 -
17 17  * **Interface**: RS485. 9600 Baud Rate
18 -
19 19  * **EC Range & Resolution:**
20 20  ** **ECK0.01** : 0.02 ~~ 20 μS/cm
21 21  ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm
22 22  ** **ECK1.0** : 2 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
23 23  ** **ECK10.0** : 20 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 -
25 25  * **EC Accuracy**: ±1% FS
26 -
27 27  * **Temperature Measure Range**: -20 ~~ 60 °C
28 -
29 29  * **Temperature Accuracy: **±0.5 °C
30 -
31 31  * **IP Rated**: IP68
32 -
33 33  * **Max Pressure**: 0.6MPa
34 34  
35 -
36 36  == 1.2 Application for Different Range ==
37 37  
38 38  
... ... @@ -205,8 +205,7 @@
205 205  
206 206  This device uses one-point calibration, and you need to prepare a known E standard solution. When mileage K=1, 1~~2000 uses 1413μS/cm standard solution, and when mileage K=10, 10~~20000 uses 12.88mS/cm standard solution.
207 207  
208 -(% style="color:blue" %)**The calibration steps are as follows:**
209 -
199 +**The calibration steps are as follows:**
210 210  (1) Place the electrode in distilled water and clean it. When mileage 1~~2000 uses 1413μS/cm standard solution, enter the following calibration command after the data is stable.
211 211  
212 212  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %)
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved