<
From version < 45.62 >
edited by Xiaoling
on 2024/08/06 14:44
To version < 45.66 >
edited by Xiaoling
on 2024/08/06 14:49
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,19 +11,28 @@
11 11  
12 12  
13 13  * **Power Input**: DC7~~30
14 +
14 14  * **Power Consumption** : < 0.5W
16 +
15 15  * **Interface**: RS485. 9600 Baud Rate
18 +
16 16  * **EC Range & Resolution:**
17 17  ** **ECK0.01** : 0.02 ~~ 20 μS/cm
18 18  ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm
19 19  ** **ECK1.0** : 2 ~~ 2,000 μS/cm  Resolution: 1 μS/cm
20 20  ** **ECK10.0** : 20 ~~ 20,000 μS/cm  Resolution: 10 μS/cm
24 +
21 21  * **EC Accuracy**: ±1% FS
26 +
22 22  * **Temperature Measure Range**: -20 ~~ 60 °C
28 +
23 23  * **Temperature Accuracy: **±0.5 °C
30 +
24 24  * **IP Rated**: IP68
32 +
25 25  * **Max Pressure**: 0.6MPa
26 26  
35 +
27 27  == 1.2 Application for Different Range ==
28 28  
29 29  
... ... @@ -84,8 +84,11 @@
84 84  
85 85  
86 86  * The equipment itself generally does not require daily maintenance. When an obvious fault occurs, please do not open it and repair it yourself, and contact us as soon as possible.
96 +
87 87  * If the electrode is not used for a long time, it can generally be stored in a dry place, but it must be placed (stored) in distilled water for several hours before use to activate the electrode. Electrodes that are frequently used can be placed (stored) in distilled water.
98 +
88 88  * Cleaning of conductivity electrodes: Organic stains on the electrode can be cleaned with warm water containing detergent, or with alcohol. Calcium and magnesium precipitates are best cleaned with 10% citric acid. The electrode plate or pole can only be cleaned by chemical methods or by shaking in water. Wiping the electrode plate will damage the coating (platinum black) on the electrode surface.
100 +
89 89  * The equipment should be calibrated before each use. It is recommended to calibrate it every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.).
90 90  
91 91  == 1.7 RS485 Commands ==
... ... @@ -196,7 +196,8 @@
196 196  
197 197  This device uses one-point calibration, and you need to prepare a known E standard solution. When mileage K=1, 1~~2000 uses 1413μS/cm standard solution, and when mileage K=10, 10~~20000 uses 12.88mS/cm standard solution.
198 198  
199 -**The calibration steps are as follows:**
211 +(% style="color:blue" %)**The calibration steps are as follows:**
212 +
200 200  (1) Place the electrode in distilled water and clean it. When mileage 1~~2000 uses 1413μS/cm standard solution, enter the following calibration command after the data is stable.
201 201  
202 202  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %)
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0