Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -309,13 +309,17 @@ 309 309 The equipment should be calibrated before each use. For long-term use, it is recommended to calibrate once every 3 months. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time. 310 310 ))) 311 311 312 + 312 312 == 2.6 RS485 Commands == 313 313 315 + 314 314 RS485 signaldefault address 0x10 315 315 Standard Modbus-RTU protocol, baud rate: 9600; check bit: none; data bit: 8; stop bit: 1 316 316 319 + 317 317 === 2.6.1 Query address === 318 318 322 + 319 319 send 320 320 321 321 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:676.25px" %) ... ... @@ -328,6 +328,7 @@ 328 328 |=(% style="width: 50px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 329 329 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 330 330 335 + 331 331 === 2.6.2 Change address === 332 332 333 333 For example: Change the address of the sensor with address 1 to 2, master → slave