Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -3,10 +3,13 @@ 3 3 {{toc/}} 4 4 5 5 6 + 7 + 6 6 = 1. DR-ECK Water EC Probe = 7 7 8 8 == 1.1 Specification: == 9 9 12 + 10 10 * **Power Input**: DC7~~30 11 11 * **Power Consumption** : < 0.5W 12 12 * **Interface**: RS485. 9600 Baud Rate ... ... @@ -21,18 +21,23 @@ 21 21 * **IP Rated**: IP68 22 22 * **Max Pressure**: 0.6MPa 23 23 27 + 28 + 24 24 == 1.2 Application for Different Range == 25 25 31 + 26 26 [[image:image-20240714173018-1.png]] 27 27 28 28 29 29 == 1.3 Wiring == 30 30 37 + 31 31 [[image:image-20240720172533-1.png||height="347" width="569"]] 32 32 33 33 34 34 == 1.4 Mechinical Drawing == 35 35 43 + 36 36 [[image:image-20240714174241-2.png]] 37 37 38 38 ... ... @@ -39,19 +39,19 @@ 39 39 == 1.5 Installation == 40 40 41 41 42 -**Electrode installation form** 50 +**Electrode installation form:** 43 43 44 -A:Side wall installation 52 +A: Side wall installation 45 45 46 -B:Top flange installation 54 +B: Top flange installation 47 47 48 -C:Pipeline bend installation 56 +C: Pipeline bend installation 49 49 50 -D:Pipeline bend installation 58 +D: Pipeline bend installation 51 51 52 -E:Flow-through installation 60 +E: Flow-through installation 53 53 54 -F:Submerged installation 62 +F: Submerged installation 55 55 56 56 [[image:image-20240718190121-1.png||height="350" width="520"]] 57 57 ... ... @@ -63,11 +63,11 @@ 63 63 64 64 [[image:image-20240718190204-2.png||height="262" width="487"]] 65 65 66 -Error cause: The electrode joint is too long, the extension part is too short, the sensor is easy to form a dead cavity, resulting in measurement error. 74 +**Error cause:** The electrode joint is too long, the extension part is too short, the sensor is easy to form a dead cavity, resulting in measurement error. 67 67 68 68 [[image:image-20240718190221-3.png||height="292" width="500"]] 69 69 70 -Error cause: Measurement error or instability may occur due to water flow not being able to fill the pipe or air accumulation at high altitudes. 78 +**Error cause: **Measurement error or instability may occur due to water flow not being able to fill the pipe or air accumulation at high altitudes. 71 71 72 72 B. Correct installation method 73 73 ... ... @@ -82,6 +82,8 @@ 82 82 * Cleaning of conductivity electrodes: Organic stains on the electrode can be cleaned with warm water containing detergent, or with alcohol. Calcium and magnesium precipitates are best cleaned with 10% citric acid. The electrode plate or pole can only be cleaned by chemical methods or by shaking in water. Wiping the electrode plate will damage the coating (platinum black) on the electrode surface. 83 83 * The equipment should be calibrated before each use. It is recommended to calibrate it every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). 84 84 93 + 94 + 85 85 == 1.7 RS485 Commands == 86 86 87 87 ... ... @@ -91,9 +91,10 @@ 91 91 92 92 === 1.7.1 Query address === 93 93 94 -send 95 95 96 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:599.333px" %) 105 +**send** 106 + 107 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) 97 97 |=(% style="width: 50px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 64px; background-color: rgb(79, 129, 189); color: white;" %)Address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Address low|=(% style="width: 70px; background-color: rgb(79, 129, 189); color: white;" %)Quantity high|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 56px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 56px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 98 98 |(% style="width:99px" %)0XFE |(% style="width:72px" %)0X03|(% style="width:64px" %)0X00|(% style="width:68px" %)0X50|(% style="width:70px" %)0X00|(% style="width:72px" %)0X00|(% style="width:56px" %)0X51|(% style="width:56px" %)0XD4 99 99 ... ... @@ -100,14 +100,17 @@ 100 100 If you forget the original address of the sensor, you can use the broadcast address 0XFE instead. When using 0XFE, the host can only connect to one slave, which can be used as a method of address query. 101 101 102 102 103 -response 114 +**response** 104 104 105 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:5 61.333px" %)116 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) 106 106 |=(% style="width: 50px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 107 107 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 108 108 120 + 121 + 109 109 === 1.7.2 Change address === 110 110 124 + 111 111 For example: Change the address of the sensor with address 1 to 2, master → slave 112 112 113 113 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:575.333px" %)