... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.karry - Content
-
... ... @@ -3,4 +3,96 @@ 3 3 {{toc/}} 4 4 5 5 6 -= 1. DR-ECK1 Water EC Probe (0 ~~ 2,000 μS/cm) = 6 += 1. DR-ECK Water EC Probe = 7 + 8 +== 1.1 Specification: == 9 + 10 +* **Power Input**: DC7~~30 11 +* **Power Consumption** : < 0.5W 12 +* **Interface**: RS485. 9600 Baud Rate 13 +* **EC Range & Resolution:** 14 +** **ECK0.01** : 0.02 ~~ 20 μS/cm 15 +** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 16 +** **ECK1.0** : 2 ~~ 2,000 μS/cm Resolution: 1 μS/cm 17 +** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm 18 +* **EC Accuracy**: ±1% FS 19 +* **Temperature Measure Range**: -20 ~~ 60 °C 20 +* **Temperature Accuracy: **±0.5 °C 21 +* **IP Rated**: IP68 22 +* **Max Pressure**: 0.6MPa 23 + 24 +== 1.2 Application for Different Range == 25 + 26 +[[image:image-20240714173018-1.png]] 27 + 28 + 29 +== 1.3 Wiring == 30 + 31 + 32 +== 1.4 Mechinical Drawing == 33 + 34 +[[image:image-20240714174241-2.png]] 35 + 36 + 37 +== 1.5 Installation == 38 + 39 + 40 +== 1.6 Maintain == 41 + 42 + 43 +== 1.7 RS485 Commands == 44 + 45 +The address of the EC K1 sensor is 11 46 + 47 +The query data command is 11 03 00 00 00 02 C6 9B 48 + 49 +For example, the returned data is 11 03 04 02 AE 01 64 8B D0, 02 AE is converted to decimal 686, K=1, EC: 686uS/cm 50 + 51 + 52 +The address of the EC K1 sensor is 12 53 + 54 +The query data command is 12 03 00 00 00 02 C6 A8 55 + 56 +~; when K=10, EC: 6860uS/cm. 57 + 58 += 2. DR-PH01 Water PH Sensor = 59 + 60 +== 2.7 RS485 Commands == 61 + 62 +The address of the dissolved oxygen sensor is 12 63 + 64 +The query data command is 14 03 00 14 00 01 C6 CB 65 + 66 + 67 += 3. DR-ORP1 Water ORP Sensor = 68 + 69 +== 3.7 RS485 Commands == 70 + 71 + 72 +The address of the dissolved oxygen sensor is 13 73 + 74 +The query data command is 14 03 00 14 00 01 C6 CB 75 + 76 + 77 += 4. DR-DO1 Dissolved Oxygen Sensor = 78 + 79 +== 4.7 RS485 Commands == 80 + 81 +The address of the dissolved oxygen sensor is 14 82 + 83 +The query data command is 14 03 00 14 00 01 C6 CB 84 + 85 +After the query, 7 bytes will be returned. For example, the returned data is 14 03 02 03 78 B5 55. 03 78 is the value of dissolved oxygen. 86 + 87 +Converted to decimal, it is 888. Add two decimal places to get the actual value. 03 78 means the current dissolved oxygen is 8.88mg/L 88 + 89 += 5. DR-TS1 Water Turbidity Sensor = 90 + 91 +== 5.7 RS485 Commands == 92 + 93 + 94 +The address of the dissolved oxygen sensor is 15 95 + 96 +The query data command is 15 03 00 14 00 01 C6 CB 97 + 98 +
- image-20240714173018-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +95.3 KB - Content
- image-20240714174241-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.9 KB - Content