Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -91,9 +91,9 @@ 91 91 92 92 send 93 93 94 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width: 676.25px" %)95 -|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width:50px;background-color:#4F81BD;color:white" %)Address high|=(% style="width:50px;background-color:#4F81BD;color:white" %)Address low|=(% style="width:50px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width:1px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)CRC16 high96 -|(% style="width:99px" %)0XFE |(% style="width: 112px" %)0X03|(% style="width:135px" %)0X00|(% style="width:126px" %)0X50|(% style="width:85px" %)0X00|(% style="width:1px" %)0X00|(% style="width:1px" %)0X51|(% style="width:1px" %)0XD494 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:599.333px" %) 95 +|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 64px; background-color: rgb(79, 129, 189); color: white;" %)Address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Address low|=(% style="width: 70px; background-color: rgb(79, 129, 189); color: white;" %)Quantity high|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 56px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 56px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 96 +|(% style="width:99px" %)0XFE |(% style="width:72px" %)0X03|(% style="width:64px" %)0X00|(% style="width:68px" %)0X50|(% style="width:70px" %)0X00|(% style="width:72px" %)0X00|(% style="width:56px" %)0X51|(% style="width:56px" %)0XD4 97 97 98 98 If you forget the original address of the sensor, you can use the broadcast address 0XFE instead. When using 0XFE, the host can only connect to one slave, which can be used as a method of address query. 99 99 ... ... @@ -108,9 +108,9 @@ 108 108 109 109 For example: Change the address of the sensor with address 1 to 2, master → slave 110 110 111 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width: 676.25px" %)112 -|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Original address|=(% style="width:50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width:50px;background-color:#4F81BD;color:white" %)Address high|=(% style="width:50px;background-color:#4F81BD;color:white" %)Address low|=(% style="width:50px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width:1px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)CRC16 high113 -|(% style="width:9 9px" %)0X01|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X50|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0X08|(% style="width:1px" %)0X1A111 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:575.333px" %) 112 +|=(% style="width: 69px; background-color: rgb(79, 129, 189); color: white;" %)Original address|=(% style="width: 76px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 67px; background-color: rgb(79, 129, 189); color: white;" %)Address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Address low|=(% style="width: 73px; background-color: rgb(79, 129, 189); color: white;" %)Quantity high|=(% style="width: 73px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 57px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 56px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 113 +|(% style="width:69px" %)0X01|(% style="width:76px" %)0X06|(% style="width:67px" %)0X00|(% style="width:68px" %)0X50|(% style="width:73px" %)0X00|(% style="width:73px" %)0X02|(% style="width:57px" %)0X08|(% style="width:56px" %)0X1A 114 114 115 115 If the sensor receives correctly, the data is returned along the original path. 116 116 Note: If you forget the original address of the sensor, you can use the broadcast address 0XFE instead. When using 0XFE, the host can only connect to one slave, and the return address is still the original address, which can be used as a method of address query. ... ... @@ -278,7 +278,7 @@ 278 278 RS485 signaldefault address 0x10 279 279 Standard Modbus-RTU protocol, baud rate: 9600; check bit: none; data bit: 8; stop bit: 1 280 280 281 -=== 2.6.1 Query data===281 +=== 2.6.1 Query address === 282 282 283 283 send 284 284 ... ... @@ -380,11 +380,11 @@ 380 380 = 3. DR-ORP1 Water ORP Sensor = 381 381 382 382 383 - 384 384 == 3.1 Specification == 385 385 386 386 * **Power Input**: DC7~~30 387 -* **Power Consumption** : < 0.5W 386 +* **Measuring range**:** **-1999~~1999mV 387 +**Resolution**: 1mV 388 388 * **Interface**: RS485. 9600 Baud Rate 389 389 * **Measurement error**: ±3mV 390 390 * **Stability**: ≤2mv/24 hours ... ... @@ -418,17 +418,25 @@ 418 418 [[image:image-20240718191336-5.png||height="239" width="326"]] 419 419 420 420 421 -=== 6.3.5 Maintenance ===421 +=== 3.5 Maintenance === 422 422 423 423 424 424 (1) The equipment itself generally does not require daily maintenance. When an obvious fault occurs, please do not open it and repair it yourself, and contact us as soon as possible. 425 + 425 425 (2) In general, ORP electrodes do not need to be calibrated and can be used directly. When there is doubt about the quality and test results of the ORP electrode, the electrode potential can be checked with an ORP standard solution to determine whether the ORP electrode meets the measurement requirements, and the electrode can be recalibrated or replaced with a new ORP electrode. The frequency of calibration or inspection of the measuring electrode depends on different application conditions (the degree of dirt in the application, the deposition of chemical substances, etc.). 427 + 426 426 (3) There is an appropriate soaking solution in the protective bottle at the front end of the electrode, and the electrode head is soaked in it to ensure the activation of the platinum sheet and the liquid junction. When measuring, loosen the bottle cap, pull out the electrode, and rinse it with pure water before use. 429 + 427 427 (4) Preparation of electrode soaking solution: Take 25 grams of analytical pure potassium chloride and dissolve it in 100 ml of pure water to prepare a 3.3M potassium chloride solution. 431 + 428 428 (5) Before measuring, the bubbles in the electrode glass bulb should be shaken off, otherwise it will affect the measurement. When measuring, the electrode should be stirred in the measured solution and then placed still to accelerate the response. 433 + 429 429 (6) The electrode should be cleaned with deionized water before and after the measurement to ensure the measurement accuracy. 435 + 430 430 (7) After long-term use, the ORP electrode will be passivated, which is manifested as a decrease in sensitivity gradient, slow response, and inaccurate readings. At this time, the platinum sheet at the bottom of the electrode can be soaked in 0.1M dilute hydrochloric acid for 24 hours (0.1M dilute hydrochloric acid preparation: 9 ml of hydrochloric acid is diluted to 1000 ml with distilled water), and then soaked in 3.3M potassium chloride solution for 24 hours to restore its performance. 437 + 431 431 (8) Electrode contamination or liquid junction blockage can also cause electrode passivation. At this time, it should be cleaned with an appropriate solution according to the nature of the contaminant. If the platinum of the electrode is severely contaminated and an oxide film is formed, toothpaste can be applied to the platinum surface and then gently scrubbed to restore the platinum's luster. 439 + 432 432 (9) The equipment should be calibrated before each use. It is recommended to calibrate once every 3 months for long-term use. The calibration frequency should be adjusted appropriately according to different application conditions (degree of dirt in the application, deposition of chemical substances, etc.). After aging, the electrodes should be replaced in time. 433 433 434 434 == 3.6 RS485 Commands == ... ... @@ -437,7 +437,7 @@ 437 437 RS485 signaldefault address 0x13 438 438 Standard Modbus-RTU protocol, baud rate: 9600; check bit: none; data bit: 8; stop bit: 1 439 439 440 -=== 3.6.1 Query data===448 +=== 3.6.1 Query address === 441 441 442 442 send 443 443 ... ... @@ -451,8 +451,6 @@ 451 451 |=(% style="width: 50px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 452 452 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 453 453 454 - 455 - 456 456 === 3.6.2 Change address === 457 457 458 458 For example: Change the address of the sensor with address 1 to 2, master → slave ... ... @@ -522,13 +522,72 @@ 522 522 0XC3 523 523 ))) 524 524 531 += 4. DR-DO1 Dissolved Oxygen Sensor = 525 525 526 526 527 -= 4. DR-DO1 Dissolved Oxygen Sensor = 528 528 529 -== 4. 7RS485 Commands==535 +== 4.1 Specification == 530 530 531 531 538 +* **Measuring range**: 0-20mg/L, 0-50℃ 539 +* **Accuracy**: 3%, ±0.5℃ 540 +* **Resolution**: 0.01 mg/L, 0.01℃ 541 +* **Maximum operating pressure**: 6 bar 542 +* **Output signal**: A: 4-20mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 543 +* **Power supply voltage**: 5-24V DC 544 +* **Working environment**: temperature 0-60℃; humidity <95%RH 545 +* **Power consumption**: ≤0.5W 546 + 547 +== 4.2 wiring == 548 + 549 + 550 + 551 +== (% id="cke_bm_224234S" style="display:none" %) (%%)4.3 Impedance requirements for current signals == 552 + 553 +[[image:image-20240718195414-8.png||height="100" width="575"]] 554 + 555 + 556 +== 4.4 Mechinical Drawing == 557 + 558 + 559 +[[image:image-20240719155308-1.png||height="226" width="527"]] 560 + 561 + 562 +=== 4.5 Instructions for use and maintenance === 563 + 564 +* It can be directly put into water without adding a protective tube, ensuring the long-term stability, reliability and accuracy of the sensor. 565 +* If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 566 + 567 +== 4.6 RS485 Commands == 568 + 569 +=== 4.6.1 Query address === 570 + 571 +send 572 + 573 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:599.333px" %) 574 +|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 64px; background-color: rgb(79, 129, 189); color: white;" %)Address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Address low|=(% style="width: 70px; background-color: rgb(79, 129, 189); color: white;" %)Quantity high|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 56px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 56px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 575 +|(% style="width:99px" %)0XFE |(% style="width:72px" %)0X03|(% style="width:64px" %)0X00|(% style="width:68px" %)0X50|(% style="width:70px" %)0X00|(% style="width:72px" %)0X00|(% style="width:56px" %)0X51|(% style="width:56px" %)0XD4 576 + 577 +If you forget the original address of the sensor, you can use the broadcast address 0XFE instead. When using 0XFE, the host can only connect to one slave, which can be used as a method of address query. 578 + 579 + 580 +response 581 + 582 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:561.333px" %) 583 +|=(% style="width: 50px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 584 +|(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 585 + 586 +=== 4.6.2 Change address === 587 + 588 +For example: Change the address of the sensor with address 1 to 2, master → slave 589 + 590 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:907.333px" %) 591 +|=(% style="width: 67px; background-color: rgb(79, 129, 189); color: white;" %)Original address|=(% style="width: 71px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 65px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address high|=(% style="width: 65px; background-color: rgb(79, 129, 189); color: white;" %)Starting register address low|=(% style="width: 70px; background-color: rgb(79, 129, 189); color: white;" %)Register length high|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)Register length low|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)Start address high|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)Start address low|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)Sensor version|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)Sensor version|=(% style="width: 56px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low 592 +|(% style="width:67px" %)0X01|(% style="width:71px" %)0X10|(% style="width:65px" %)0X00|(% style="width:65px" %)0X0A|(% style="width:70px" %)0X00|(% style="width:72px" %)0X02|(% style="width:53px" %)0X04|(% style="width:53px" %)0X00|(% style="width:72px" %)0X02|(% style="width:53px" %)0X00|(% style="width:53px" %)0X00|(% style="width:56px" %)0XD2|(% style="width:53px" %)0X10 593 + 594 +=== 4.6.2 Query data === 595 + 596 + 532 532 The address of the dissolved oxygen sensor is 14 533 533 534 534 The query data command is 14 03 00 14 00 01 C6 CB ... ... @@ -540,9 +540,59 @@ 540 540 541 541 = 5. DR-TS1 Water Turbidity Sensor = 542 542 543 -== 5.7 RS485 Commands == 544 544 545 545 610 +== (% id="cke_bm_81470S" style="display:none" %) (%%)5.1 Specification == 611 + 612 +* **Measuring range**: 0.1~1000.0NTU 613 +* **Accuracy**: ±5% 614 +* **Resolution**: 0.1NTU 615 +* **Stability**: ≤3mV/24 hours 616 +* **Output signal**: A: 4~20 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 617 +* **Power supply voltage**: 5~24V DC (when output signal is RS485)12~24V DC (when output signal is 4~20mA) 618 +* **Working environment**: temperature 0~60℃; humidity ≤95%RH 619 +* **Power consumption**: ≤0.5W 620 + 621 +== 5.2 wiring == 622 + 623 + 624 +== 5.3 Impedance requirements for current signals == 625 + 626 +[[image:image-20240718195414-8.png||height="100" width="575"]] 627 + 628 + 629 +== 5.4 Mechinical Drawing == 630 + 631 +[[image:image-20240718195058-7.png||height="305" width="593"]] 632 + 633 + 634 +=== 5.5 Instructions for use and maintenance === 635 + 636 +* It can be directly put into water without adding a protective tube, ensuring the long-term stability, reliability and accuracy of the sensor. 637 +* If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 638 + 639 +== 5.6 RS485 Commands == 640 + 641 +=== 4.6.1 Query address === 642 + 643 +send 644 + 645 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:599.333px" %) 646 +|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Original address|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)Function code|=(% style="width: 64px; background-color: rgb(79, 129, 189); color: white;" %)Address high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Address low|=(% style="width: 70px; background-color: rgb(79, 129, 189); color: white;" %)Quantity high|=(% style="width: 72px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 56px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 56px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 647 +|(% style="width:99px" %)0XFE |(% style="width:72px" %)0X03|(% style="width:64px" %)0X00|(% style="width:68px" %)0X50|(% style="width:70px" %)0X00|(% style="width:72px" %)0X00|(% style="width:56px" %)0X51|(% style="width:56px" %)0XD4 648 + 649 +If you forget the original address of the sensor, you can use the broadcast address 0XFE instead. When using 0XFE, the host can only connect to one slave, which can be used as a method of address query. 650 + 651 + 652 +response 653 + 654 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:561.333px" %) 655 +|=(% style="width: 50px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 656 +|(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 657 + 658 +=== 5.6.2 Query data === 659 + 660 + 546 546 The address of the dissolved oxygen sensor is 15 547 547 548 548 The query data command is 15 03 00 00 00 01 87 1E
- image-20240719155308-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +57.4 KB - Content