Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -380,11 +380,11 @@ 380 380 = 3. DR-ORP1 Water ORP Sensor = 381 381 382 382 383 - 384 384 == 3.1 Specification == 385 385 386 386 * **Power Input**: DC7~~30 387 -* **Power Consumption** : < 0.5W 386 +* **Measuring range**:** **-1999~~1999mV 387 +**Resolution**: 1mV 388 388 * **Interface**: RS485. 9600 Baud Rate 389 389 * **Measurement error**: ±3mV 390 390 * **Stability**: ≤2mv/24 hours ... ... @@ -452,7 +452,6 @@ 452 452 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 453 453 454 454 455 - 456 456 === 3.6.2 Change address === 457 457 458 458 For example: Change the address of the sensor with address 1 to 2, master → slave ... ... @@ -523,12 +523,44 @@ 523 523 ))) 524 524 525 525 526 - 527 527 = 4. DR-DO1 Dissolved Oxygen Sensor = 528 528 529 -== 4.7 RS485 Commands == 530 530 531 531 529 +== 4.1 Specification == 530 + 531 +* **Measuring range**: 0.1~1000.0NTU 532 +* **Accuracy**: ±5% 533 +* **Resolution**: 0.1NTU 534 +* **Stability**: ≤3mV/24 hours 535 +* **Output signal**: A: 4~20 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 536 +* **Power supply voltage**: 5~24V DC (when output signal is RS485)12~24V DC (when output signal is 4~20mA) 537 +* **Working environment**: temperature 0~60℃; humidity ≤95%RH 538 +* **Power consumption**: ≤0.5W 539 + 540 + 541 +== 4.2 Impedance requirements for current signals == 542 + 543 +[[image:image-20240718195414-8.png||height="100" width="575"]] 544 + 545 + 546 +== 4.3 wiring == 547 + 548 +== 4.4 Mechinical Drawing == 549 + 550 +[[image:image-20240718195058-7.png||height="305" width="593"]] 551 + 552 + 553 +=== 4.5 Instructions for use and maintenance === 554 + 555 +* It can be directly put into water without adding a protective tube, ensuring the long-term stability, reliability and accuracy of the sensor. 556 +* If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently. 557 + 558 + 559 +== 4.6 RS485 Commands == 560 + 561 +4.6.1 562 + 532 532 The address of the dissolved oxygen sensor is 14 533 533 534 534 The query data command is 14 03 00 14 00 01 C6 CB
- image-20240718195058-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +97.6 KB - Content
- image-20240718195414-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.5 KB - Content