380 380  = 3. DR-ORP1 Water ORP Sensor =
381 381  
382 382  
383 -
384 384  == 3.1 Specification ==
385 385  
386 386  * **Power Input**: DC7~~30
387 -* **Power Consumption** : < 0.5W
386 +* **Measuring range**:** **-1999~~1999mV
387 +**Resolution**: 1mV
388 388  * **Interface**: RS485. 9600 Baud Rate
389 389  * **Measurement error**: ±3mV
390 390  * **Stability**: ≤2mv/24 hours
... ... @@ -452,7 +452,6 @@
452 452  |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0
453 453  
454 454  
455 -
456 456  === 3.6.2 Change address ===
457 457  
458 458  For example: Change the address of the sensor with address 1 to 2, master → slave
... ... @@ -523,12 +523,44 @@
523 523  )))
524 524  
525 525  
526 -
527 527  = 4. DR-DO1 Dissolved Oxygen Sensor =
528 528  
529 -== 4.7 RS485 Commands ==
530 530  
531 531  
529 +== 4.1 Specification ==
530 +
531 +* **Measuring range**: 0.1~1000.0NTU
532 +* **Accuracy**: ±5%
533 +* **Resolution**: 0.1NTU
534 +* **Stability**: ≤3mV/24 hours
535 +* **Output signal**: A: 4~20 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01)
536 +* **Power supply voltage**: 5~24V DC (when output signal is RS485)12~24V DC (when output signal is 4~20mA)
537 +* **Working environment**: temperature 0~60℃; humidity ≤95%RH
538 +* **Power consumption**: ≤0.5W
539 +
540 +
541 +== 4.2 Impedance requirements for current signals ==
542 +
543 +[[image:image-20240718195414-8.png||height="100" width="575"]]
544 +
545 +
546 +== 4.3 wiring ==
547 +
548 +== 4.4 Mechinical Drawing ==
549 +
550 +[[image:image-20240718195058-7.png||height="305" width="593"]]
551 +
552 +
553 +=== 4.5 Instructions for use and maintenance ===
554 +
555 +* It can be directly put into water without adding a protective tube, ensuring the long-term stability, reliability and accuracy of the sensor.
556 +* If the water conditions are complex and you want accurate data, you need to wipe the sensor probe frequently.
557 +
558 +
559 +== 4.6 RS485 Commands ==
560 +
561 +4.6.1
562 +
532 532  The address of the dissolved oxygen sensor is 14
533 533  
534 534  The query data command is 14 03 00 14 00 01 C6 CB
image-20240718195058-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +97.6 KB
Content
image-20240718195414-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +13.5 KB
Content