37 37  == 1.5 Installation ==
38 38  
39 39  
40 -**Electrode installation form**
40 + Do not power on while connect the cables. Double check the wiring before power on.
41 41  
42 -A:Side wall installation
42 +Installation Photo as reference:
43 43  
44 -B:Top flange installation
44 +**~ Submerged installation:**
45 45  
46 -C:Pipeline bend installation
46 +The lead wire of the equipment passes through the waterproof pipe, and the 3/4 thread on the top of the equipment is connected to the 3/4 thread of the waterproof pipe with raw tape. Ensure that the top of the equipment and the equipment wire are not flooded.
47 47  
48 -D:Pipeline bend installation
48 +[[image:image-20240715181933-4.png||height="281" width="258"]]
49 49  
50 -E:Flow-through installation
50 +**~ Pipeline installation:**
51 51  
52 -F:Submerged installation
52 +Connect the equipment to the pipeline through the 3/4 thread.
53 53  
54 -[[image:image-20240718190121-1.png||height="350" width="520"]]
54 +[[image:image-20240715182122-6.png||height="291" width="408"]]
55 55  
56 -**Several common installation methods of electrodes**
56 +**Sampling:**
57 57  
58 -When installing the sensor on site, you should strictly follow the correct installation method shown in the following picture. Incorrect installation method will cause data deviation.
58 +Take representative water samples according to sampling requirements. If it is inconvenient to take samples, you can also put the electrode into the solution to be tested and read the output data. After a period of time, take out the electrode and clean it.
59 59  
60 -A. Several common incorrect installation methods
60 +**Measure the pH of the water sample:**
61 61  
62 -[[image:image-20240718190204-2.png||height="262" width="487"]]
62 +First rinse the electrode with distilled water, then rinse it with the water sample, then immerse the electrode in the sample, carefully shake the test cup or stir it to accelerate the electrode balance, let it stand, and record the pH value when the reading is stable.
63 63  
64 -Error cause: The electrode joint is too long, the extension part is too short, the sensor is easy to form a dead cavity, resulting in measurement error.
65 65  
66 -[[image:image-20240718190221-3.png||height="292" width="500"]]
67 -
68 -Error cause: Measurement error or instability may occur due to water flow not being able to fill the pipe or air accumulation at high altitudes.
69 -
70 -B. Correct installation method
71 -
72 -[[image:image-20240718190249-4.png||height="287" width="515"]]
73 -
74 -
75 75  == 1.6 Maintain ==
76 76  
77 77  
... ... @@ -146,6 +146,7 @@
146 146  0XE5
147 147  )))
148 148  
139 +
149 149  === 1.7.4 Query data ===
150 150  
151 151  The address of the EC K10 sensor is 11
... ... @@ -212,6 +212,10 @@
212 212  |=(% style="width: 50px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 1px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)CRC16 high
213 213  |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50
214 214  
206 +
207 +
208 +
209 +
215 215  = 2. DR-PH01 Water PH Sensor =
216 216  
217 217  == 2.7 RS485 Commands ==
... ... @@ -267,3 +267,4 @@
267 267  
268 268  02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU
269 269  
265 +
image-20240718190121-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -281.1 KB
Content
image-20240718190204-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -111.8 KB
Content
image-20240718190221-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -140.2 KB
Content
image-20240718190249-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.karry
Size
... ... @@ -1,1 +1,0 @@
1 -111.6 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0