Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
Change comment:
Uploaded new attachment "image-20240718191336-5.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -37,31 +37,41 @@ 37 37 == 1.5 Installation == 38 38 39 39 40 - Do not powern whileconnectthe cables. Double checkthe wiringbefore power on.40 +**Electrode installation form** 41 41 42 - InstallationPhoto as reference:42 +A:Side wall installation 43 43 44 - **~Submergedinstallation:**44 +B:Top flange installation 45 45 46 - The lead wire of the equipment passes through the waterproof pipe, and the3/4 thread onthe top of the equipment is connectedto the 3/4 thread of the waterproof pipe with raw tape. Ensurethat the top of the equipmentandthe equipment wire are not flooded.46 +C:Pipeline bend installation 47 47 48 - [[image:image-20240715181933-4.png||height="281"width="258"]]48 +D:Pipeline bend installation 49 49 50 - **~ Pipelineinstallation:**50 +E:Flow-through installation 51 51 52 - Connect the equipment to thepipelinethrough the 3/4 thread.52 +F:Submerged installation 53 53 54 -[[image:image-2024071 5182122-6.png||height="291" width="408"]]54 +[[image:image-20240718190121-1.png||height="350" width="520"]] 55 55 56 -**Sam pling:**56 +**Several common installation methods of electrodes** 57 57 58 - Takerepresentativewatersamplesaccordingto samplingrequirements.Ifitis inconvenienttake samples, youcan also put the electrodeintothesolution to betested andreadtheoutput data. After a periodof time,take out the electrodeandcleanit.58 +When installing the sensor on site, you should strictly follow the correct installation method shown in the following picture. Incorrect installation method will cause data deviation. 59 59 60 - **Measurethe pHofthewatersample:**60 +A. Several common incorrect installation methods 61 61 62 - First rinse the electrode with distilled water, then rinse it with the water sample, thenimmerse theelectrodein the sample, carefully shakethetest cup or stir it to accelerate the electrode balance, letit stand, and record the pH value when the reading is stable.62 +[[image:image-20240718190204-2.png||height="262" width="487"]] 63 63 64 +Error cause: The electrode joint is too long, the extension part is too short, the sensor is easy to form a dead cavity, resulting in measurement error. 64 64 66 +[[image:image-20240718190221-3.png||height="292" width="500"]] 67 + 68 +Error cause: Measurement error or instability may occur due to water flow not being able to fill the pipe or air accumulation at high altitudes. 69 + 70 +B. Correct installation method 71 + 72 +[[image:image-20240718190249-4.png||height="287" width="515"]] 73 + 74 + 65 65 == 1.6 Maintain == 66 66 67 67 ... ... @@ -101,7 +101,6 @@ 101 101 |=(% style="width: 50px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 102 102 |(% style="width:99px" %)0X1|(% style="width:112px" %)0X3|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 103 103 104 - 105 105 === 1.7.2 Change address === 106 106 107 107 For example: Change the address of the sensor with address 1 to 2, master → slave ... ... @@ -137,10 +137,9 @@ 137 137 0XE5 138 138 ))) 139 139 140 - 141 141 === 1.7.4 Query data === 142 142 143 -The address of the EC K10 sensor is 151 +The address of the EC K10 sensor is 11 144 144 145 145 The query data command is 11 03 00 00 00 02 C6 9B 146 146 ... ... @@ -154,7 +154,7 @@ 154 154 For example, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm 155 155 156 156 157 -=== 7.1.5 Calibration Method ===165 +=== 1.7.5 Calibration Method === 158 158 159 159 160 160 This device uses one-point calibration, and you need to prepare a known E standard solution. When mileage K=1, 1~~2000 uses 1413μS/cm standard solution, and when mileage K=10, 10~~20000 uses 12.88mS/cm standard solution. ... ... @@ -204,11 +204,6 @@ 204 204 |=(% style="width: 50px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 1px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)CRC16 high 205 205 |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50 206 206 207 - 208 - 209 - 210 - 211 - 212 212 = 2. DR-PH01 Water PH Sensor = 213 213 214 214 == 2.7 RS485 Commands == ... ... @@ -264,4 +264,3 @@ 264 264 265 265 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 266 266 267 -
- image-20240718190121-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +281.1 KB - Content
- image-20240718190204-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.8 KB - Content
- image-20240718190221-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +140.2 KB - Content
- image-20240718190249-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +111.6 KB - Content
- image-20240718191336-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.6 KB - Content