Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/02/18 15:43
From version 13.1
edited by Karry Zhuang
on 2024/07/18 15:59
on 2024/07/18 15:59
Change comment:
There is no comment for this version
To version 11.1
edited by Karry Zhuang
on 2024/07/18 14:10
on 2024/07/18 14:10
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -42,7 +42,6 @@ 42 42 43 43 == 1.7 RS485 Commands == 44 44 45 -=== 1.7.1 Query data === 46 46 47 47 The address of the EC K10 sensor is 11 48 48 ... ... @@ -58,17 +58,6 @@ 58 58 For example, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm. 59 59 60 60 61 -=== 1.7.2 Calibration Method === 62 - 63 - 64 -This device uses one-point calibration, and you need to prepare a known E standard solution. When mileage K=1, 1~~2000 uses 1413uS/cm standard solution, and when mileage K=10, 10~~20000 uses 12.88mS/cm standard solution. The calibration steps are as follows: 65 -(1) Place the electrode in distilled water and clean it. When mileage 1~~2000 uses 1413HS/cm standard solution, enter the following calibration command after the data is stable. 66 - 67 - 68 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:676.25px" %) 69 -|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 1px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 139.083px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 50px;background-color:#4F81BD;color:white" %)Data|=(% style="width: 50px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 50px;background-color:#4F81BD;color:white" %)CRC16 high 70 -|(% style="width:99px" %) |(% style="width:112px" %) |(% style="width:135px" %) |(% style="width:126px" %) |(% style="width:85px" %) |(% style="width:1px" %) |(% style="width:1px" %) |(% style="width:1px" %) |(% style="width:1px" %) |(% style="width:1px" %) 71 - 72 72 = 2. DR-PH01 Water PH Sensor = 73 73 74 74 == 2.7 RS485 Commands ==