Changes for page WSC2-L -- Weather Station Kit User Manual
Last modified by Mengting Qiu on 2025/08/07 16:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -471,6 +471,14 @@ 471 471 [[image:1656051277767-168.png]] 472 472 473 473 474 +== 2.6 Frequency Plans == 475 + 476 + 477 +The SN50v3-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 478 + 479 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 480 + 481 + 474 474 = 3. Configure WSC2-LB = 475 475 476 476 == 3.1 Configure Methods == ... ... @@ -505,7 +505,7 @@ 505 505 These commands only valid for WSC2-LB, as below: 506 506 507 507 508 -== 3.3.1 Set Transmit Interval Time == 516 +=== 3.3.1 Set Transmit Interval Time === 509 509 510 510 511 511 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -533,7 +533,7 @@ 533 533 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 534 534 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 535 535 536 -== 3.3.2 Set Emergency Mode == 544 +=== 3.3.2 Set Emergency Mode === 537 537 538 538 539 539 Feature: In emergency mode, WSC2-LB will uplink data every 1 minute. ... ... @@ -555,7 +555,7 @@ 555 555 * 0xE101 Same as: AT+ALARMMOD=1 556 556 * 0xE100 Same as: AT+ALARMMOD=0 557 557 558 -== 3.3.3 Add or Delete RS485 Sensor == 566 +=== 3.3.3 Add or Delete RS485 Sensor === 559 559 560 560 561 561 ((( ... ... @@ -650,7 +650,7 @@ 650 650 651 651 * 0xE5FF 652 652 653 -== 3.3.4 RS485 Test Command == 661 +=== 3.3.4 RS485 Test Command === 654 654 655 655 656 656 (% style="color:#037691" %)**AT Command:** ... ... @@ -670,7 +670,7 @@ 670 670 671 671 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 672 672 673 -== 3.3.5 RS485 response timeout == 681 +=== 3.3.5 RS485 response timeout === 674 674 675 675 676 676 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -692,7 +692,7 @@ 692 692 * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds 693 693 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 694 694 695 -== 3.3.6 Set Sensor Type == 703 +=== 3.3.6 Set Sensor Type === 696 696 697 697 698 698 ((( ... ... @@ -752,7 +752,7 @@ 752 752 ~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned. 753 753 754 754 755 -== 3.3.7 Set the registers read by the rain gauge (Sincefirmware V1.3)==763 +=== 3.3.7 Set the registers read by the rain gauge === 756 756 757 757 758 758 (% style="color:#037691" %)**AT Command:**