Last modified by Mengting Qiu on 2025/08/07 16:27

From version 107.17
edited by Xiaoling
on 2023/07/18 18:05
Change comment: There is no comment for this version
To version 107.18
edited by Xiaoling
on 2023/07/18 18:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -505,7 +505,7 @@
505 505  These commands only valid for WSC2-LB, as below:
506 506  
507 507  
508 -== 3.3.1 Set Transmit Interval Time ==
508 +=== 3.3.1 Set Transmit Interval Time ===
509 509  
510 510  
511 511  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -533,7 +533,7 @@
533 533  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
534 534  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
535 535  
536 -== 3.3.2 Set Emergency Mode ==
536 +=== 3.3.2 Set Emergency Mode ===
537 537  
538 538  
539 539  Feature: In emergency mode, WSC2-LB will uplink data every 1 minute.
... ... @@ -555,7 +555,7 @@
555 555  * 0xE101     Same as: AT+ALARMMOD=1
556 556  * 0xE100     Same as: AT+ALARMMOD=0
557 557  
558 -== 3.3.3 Add or Delete RS485 Sensor ==
558 +=== 3.3.3 Add or Delete RS485 Sensor ===
559 559  
560 560  
561 561  (((
... ... @@ -650,7 +650,7 @@
650 650  
651 651  * 0xE5FF  
652 652  
653 -== 3.3.4 RS485 Test Command ==
653 +=== 3.3.4 RS485 Test Command ===
654 654  
655 655  
656 656  (% style="color:#037691" %)**AT Command:**
... ... @@ -670,7 +670,7 @@
670 670  
671 671  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
672 672  
673 -== 3.3.5 RS485 response timeout ==
673 +=== 3.3.5 RS485 response timeout ===
674 674  
675 675  
676 676  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -692,7 +692,7 @@
692 692  * Example 1: Downlink Payload: E0000005  ~/~/  Set Transmit Interval (DTR) = 5 seconds
693 693  * Example 2: Downlink Payload: E000000A  ~/~/  Set Transmit Interval (DTR) = 10 seconds
694 694  
695 -== 3.3.6 Set Sensor Type ==
695 +=== 3.3.6 Set Sensor Type ===
696 696  
697 697  
698 698  (((
... ... @@ -752,7 +752,7 @@
752 752  ~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned.
753 753  
754 754  
755 -== 3.3.7  Set the registers read by the rain gauge(Since firmware V1.3) ==
755 +=== 3.3.7  Set the registers read by the rain gauge ===
756 756  
757 757  
758 758  (% style="color:#037691" %)**AT Command:**