Show last authors
1 (% style="text-align:center" %)
2 [[image:1653266934636-343.png||height="385" width="385"]]
3
4
5
6 **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7
8
9
10
11 **Table of Contents:**
12
13 {{toc/}}
14
15
16
17
18
19
20
21 = 1.Introduction =
22
23 == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
24
25 (((
26 (((
27 (((
28 The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
29 )))
30 )))
31
32 (((
33 (((
34 RS485-LN allows user to (% style="color:blue" %)**monitor / control RS485 devices**(%%) and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
35 )))
36 )))
37
38 (((
39 (((
40 (% style="color:blue" %)**For data uplink**(%%), RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server.
41 )))
42 )))
43
44 (((
45 (((
46 (% style="color:blue" %)**For data downlink**(%%), RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices.
47 )))
48
49 (((
50 (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]]
51 )))
52 )))
53 )))
54
55 [[image:1653267211009-519.png||height="419" width="724"]]
56
57
58 == 1.2 Specifications ==
59
60
61 **Hardware System:**
62
63 * STM32L072CZT6 MCU
64 * SX1276/78 Wireless Chip 
65 * Power Consumption (exclude RS485 device):
66 ** Idle: 32mA@12v
67 ** 20dB Transmit: 65mA@12v
68
69 **Interface for Model:**
70
71 * RS485
72 * Power Input 7~~ 24V DC. 
73
74 **LoRa Spec:**
75
76 * Frequency Range:
77 ** Band 1 (HF): 862 ~~ 1020 Mhz
78 ** Band 2 (LF): 410 ~~ 528 Mhz
79 * 168 dB maximum link budget.
80 * +20 dBm - 100 mW constant RF output vs.
81 * +14 dBm high efficiency PA.
82 * Programmable bit rate up to 300 kbps.
83 * High sensitivity: down to -148 dBm.
84 * Bullet-proof front end: IIP3 = -12.5 dBm.
85 * Excellent blocking immunity.
86 * Low RX current of 10.3 mA, 200 nA register retention.
87 * Fully integrated synthesizer with a resolution of 61 Hz.
88 * FSK, GFSK, MSK, GMSK, LoRaTM and OOK modulation.
89 * Built-in bit synchronizer for clock recovery.
90 * Preamble detection.
91 * 127 dB Dynamic Range RSSI.
92 * Automatic RF Sense and CAD with ultra-fast AFC.
93 * Packet engine up to 256 bytes with CRC
94
95 == 1.3 Features ==
96
97 * LoRaWAN Class A & Class C protocol (default Class C)
98 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
99 * AT Commands to change parameters
100 * Remote configure parameters via LoRa Downlink
101 * Firmware upgradable via program port
102 * Support multiply RS485 devices by flexible rules
103 * Support Modbus protocol
104 * Support Interrupt uplink (Since hardware version v1.2)
105
106 == 1.4 Applications ==
107
108 * Smart Buildings & Home Automation
109 * Logistics and Supply Chain Management
110 * Smart Metering
111 * Smart Agriculture
112 * Smart Cities
113 * Smart Factory
114
115 == 1.5 Firmware Change log ==
116
117 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
118
119
120 == 1.6 Hardware Change log ==
121
122 (((
123 (((
124 (((
125 v1.2: Add External Interrupt Pin.
126 )))
127
128 (((
129 v1.0: Release
130 )))
131
132
133 )))
134 )))
135
136 = 2. Power ON Device =
137
138 (((
139 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
140
141 * Power Source VIN to RS485-LN VIN+
142 * Power Source GND to RS485-LN VIN-
143
144 (((
145 Once there is power, the RS485-LN will be on.
146 )))
147
148 [[image:1653268091319-405.png]]
149
150
151 )))
152
153 = 3. Operation Mode =
154
155 == 3.1 How it works? ==
156
157 (((
158 (((
159 The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
160 )))
161
162
163 )))
164
165 == 3.2 Example to join LoRaWAN network ==
166
167 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
168
169 [[image:1653268155545-638.png||height="334" width="724"]]
170
171
172 (((
173 (((
174 The RS485-LN in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. The connection is as below:
175 )))
176
177 (((
178 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
179 )))
180
181 [[image:1653268227651-549.png||height="592" width="720"]]
182
183 (((
184 The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
185 )))
186
187 (((
188 **Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN.
189 )))
190
191 (((
192 Each RS485-LN is shipped with a sticker with unique device EUI:
193 )))
194 )))
195
196 [[image:1652953462722-299.png]]
197
198 (((
199 (((
200 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
201 )))
202
203 (((
204 Add APP EUI in the application.
205 )))
206 )))
207
208 [[image:image-20220519174512-1.png]]
209
210 [[image:image-20220519174512-2.png||height="323" width="720"]]
211
212 [[image:image-20220519174512-3.png||height="556" width="724"]]
213
214 [[image:image-20220519174512-4.png]]
215
216 You can also choose to create the device manually.
217
218 [[image:1652953542269-423.png||height="710" width="723"]]
219
220 Add APP KEY and DEV EUI
221
222 [[image:1652953553383-907.png||height="514" width="724"]]
223
224
225 (((
226 **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
227 )))
228
229 [[image:1652953568895-172.png||height="232" width="724"]]
230
231
232 == 3.3 Configure Commands to read data ==
233
234 (((
235 (((
236 (((
237 There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
238 )))
239 )))
240
241 (((
242 (((
243 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
244 )))
245
246
247 )))
248 )))
249
250 === 3.3.1 onfigure UART settings for RS485 or TTL communication ===
251
252 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
253
254 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
255 |=(% style="width: 110px;" %)(((
256 **AT Commands**
257 )))|=(% style="width: 190px;" %)(((
258 **Description**
259 )))|=(% style="width: 190px;" %)(((
260 **Example**
261 )))
262 |(% style="width:110px" %)(((
263 AT+BAUDR
264 )))|(% style="width:190px" %)(((
265 Set the baud rate (for RS485 connection). Default Value is: 9600.
266 )))|(% style="width:190px" %)(((
267 (((
268 AT+BAUDR=9600
269 )))
270
271 (((
272 Options: (1200,2400,4800,14400,19200,115200)
273 )))
274 )))
275 |(% style="width:110px" %)(((
276 AT+PARITY
277 )))|(% style="width:190px" %)(((
278 Set UART parity (for RS485 connection)
279 )))|(% style="width:190px" %)(((
280 (((
281 AT+PARITY=0
282 )))
283
284 (((
285 Option: 0: no parity, 1: odd parity, 2: even parity
286 )))
287 )))
288 |(% style="width:110px" %)(((
289 AT+STOPBIT
290 )))|(% style="width:190px" %)(((
291 (((
292 Set serial stopbit (for RS485 connection)
293 )))
294
295 (((
296
297 )))
298 )))|(% style="width:190px" %)(((
299 (((
300 AT+STOPBIT=0 for 1bit
301 )))
302
303 (((
304 AT+STOPBIT=1 for 1.5 bit
305 )))
306
307 (((
308 AT+STOPBIT=2 for 2 bits
309 )))
310 )))
311
312
313 === 3.3.2 Configure sensors ===
314
315 (((
316 (((
317 Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won’t run during each sampling.
318 )))
319 )))
320
321 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
322 |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
323 |AT+CFGDEV|(% style="width:110px" %)(((
324 This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
325
326 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
327
328 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
329 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
330
331
332 === 3.3.3 Configure read commands for each sampling ===
333
334 (((
335 During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload.
336
337 To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload.
338
339 This section describes how to achieve above goals.
340
341 During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
342
343
344 **Each RS485 commands include two parts:**
345
346 ~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar.
347
348 2. How to get wanted value the from RS485 sensors returns from by 1). There are total 15 AT Commands to handle the return, commands are **AT+DATACUT1**,**AT+DATACUT2**,…, **AT+DATACUTF** corresponding to the commands from 1). All commands are of same grammar.
349
350 3. Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example **AT+CMDDL1=1000** to send the open time to 1000ms
351
352
353 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
354
355
356 Below are examples for the how above AT Commands works.
357
358
359 **AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
360
361 (% border="1" style="background-color:#4bacc6; color:white; width:499px" %)
362 |(% style="width:496px" %)(((
363 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
364
365 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
366
367 **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command**
368 )))
369
370 For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually.
371
372 In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
373
374
375 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
376
377 (% border="1" style="background-color:#4bacc6; color:white; width:510px" %)
378 |(% style="width:510px" %)(((
379 **AT+DATACUTx=a,b,c**
380
381 * **a: length for the return of AT+COMMAND**
382 * **b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.**
383 * **c: define the position for valid value.  **
384 )))
385
386 **Examples:**
387
388 * Grab bytes:
389
390 [[image:image-20220602153621-1.png]]
391
392
393 * Grab a section.
394
395 [[image:image-20220602153621-2.png]]
396
397
398 * Grab different sections.
399
400 [[image:image-20220602153621-3.png]]
401
402
403 )))
404
405 === 3.3.4 Compose the uplink payload ===
406
407 (((
408 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
409
410
411 )))
412
413 (((
414 (% style="color:#037691" %)**Examples: AT+DATAUP=0**
415
416
417 )))
418
419 (((
420 Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**A SIGNLE UPLINK**.
421 )))
422
423 (((
424 Final Payload is
425 )))
426
427 (((
428 (% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx**
429 )))
430
431 (((
432 Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
433 )))
434
435 [[image:1653269759169-150.png||height="513" width="716"]]
436
437
438 (% style="color:#037691" %)**Examples: AT+DATAUP=1**
439
440
441 Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**Multiply UPLINKs**.
442
443 Final Payload is
444
445 (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
446
447
448 1. PAYVER: Defined by AT+PAYVER
449 1. PAYLOAD COUNT: Total how many uplinks of this sampling.
450 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
451 1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
452
453 [[image:image-20220602155039-4.png]]
454
455
456 So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
457
458 DATA1=RETURN1 Valid Value + the first two of Valid value of RETURN10= **20 20 0a 33 90 41 02 aa**
459
460 DATA2=3^^rd^^ ~~ 10^^th^^ byte of Valid value of RETURN10= **05 81 0a 20 20 20 20 2d**
461
462 DATA3=the rest of Valid value of RETURN10= **30**
463
464
465 (% style="color:red" %)Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:
466
467 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink.
468
469 * For AU915/AS923 bands, if UplinkDwell time=0, max 11 bytes for each uplink.
470
471 * For US915 band, max 11 bytes for each uplink.
472
473 ~* For all other bands: max 51 bytes for each uplink.
474
475
476 Below are the uplink payloads:
477
478 [[image:1654157178836-407.png]]
479
480
481 === 3.3.5 Uplink on demand ===
482
483 Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command.
484
485 Downlink control command:
486
487 **0x08 command**: Poll an uplink with current command set in RS485-LN.
488
489 **0xA8 command**: Send a command to RS485-LN and uplink the output from sensors.
490
491
492
493 === 3.3.6 Uplink on Interrupt ===
494
495 RS485-LN support external Interrupt uplink since hardware v1.2 release.
496
497 [[image:1654157342174-798.png]]
498
499 Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
500
501
502 == 3.4 Uplink Payload ==
503
504
505 [[image:image-20220606110929-1.png]]
506
507 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
508
509
510 == 3.5 Configure RS485-BL via AT or Downlink ==
511
512 (((
513 User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
514 )))
515
516 (((
517 There are two kinds of Commands:
518 )))
519
520 * (((
521 (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
522 )))
523
524 * (((
525 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
526 )))
527
528 (((
529
530 )))
531
532
533 === 3.5.1 Common Commands ===
534
535 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
536
537
538 === 3.5.2 Sensor related commands ===
539
540 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
541
542 [[image:image-20220602163333-5.png||height="263" width="1160"]]
543
544 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
545
546
547 === 3.5.3 Sensor related commands ===
548
549
550
551
552 ==== **RS485 Debug Command** ====
553
554 (((
555 This command is used to configure the RS485 devices; they won’t be used during sampling.
556 )))
557
558 * (((
559 **AT Command**
560 )))
561
562 (% class="box infomessage" %)
563 (((
564 (((
565 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
566 )))
567 )))
568
569 (((
570 m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
571 )))
572
573 * (((
574 **Downlink Payload**
575 )))
576
577 (((
578 Format: A8 MM NN XX XX XX XX YY
579 )))
580
581 (((
582 Where:
583 )))
584
585 * (((
586 MM: 1: add CRC-16/MODBUS ; 0: no CRC
587 )))
588 * (((
589 NN: The length of RS485 command
590 )))
591 * (((
592 XX XX XX XX: RS485 command total NN bytes
593 )))
594 * (((
595 (((
596 YY: How many bytes will be uplink from the return of this RS485 command,
597 )))
598
599 * (((
600 if YY=0, RS485-LN will execute the downlink command without uplink;
601 )))
602 * (((
603 if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
604 )))
605 * (((
606 if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
607 )))
608 )))
609
610 (((
611 **Example 1** ~-~-> Configure without ask for uplink (YY=0)
612 )))
613
614 (((
615 To connect a Modbus Alarm with below commands.
616 )))
617
618 * (((
619 The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
620 )))
621
622 * (((
623 The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
624 )))
625
626 (((
627 So if user want to use downlink command to control to RS485 Alarm, he can use:
628 )))
629
630 (((
631 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
632 )))
633
634 (((
635 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
636 )))
637
638 (((
639 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
640 )))
641
642 (((
643
644 )))
645
646 (((
647 **Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
648 )))
649
650 (((
651 User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY**
652 )))
653
654 (((
655
656 )))
657
658 (((
659 RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
660 )))
661
662 (((
663 **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
664 )))
665
666 (((
667 [[image:1654159460680-153.png]]
668 )))
669
670
671
672
673 ==== **Set Payload version** ====
674
675 (((
676 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
677 )))
678
679 * (((
680 **AT Command:**
681 )))
682
683 (% class="box infomessage" %)
684 (((
685 (((
686 **AT+PAYVER: Set PAYVER field = 1**
687 )))
688 )))
689
690 * (((
691 **Downlink Payload:**
692 )))
693
694 (((
695 **0xAE 01**  ~-~-> Set PAYVER field =  0x01
696 )))
697
698 (((
699 **0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
700 )))
701
702
703
704
705 ==== **Set RS485 Sampling Commands** ====
706
707 (((
708 AT+COMMANDx or AT+DATACUTx
709 )))
710
711 (((
712 These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
713 )))
714
715 (((
716
717 )))
718
719 * (((
720 **AT Command:**
721 )))
722
723 (% class="box infomessage" %)
724 (((
725 (((
726 **AT+COMMANDx: Configure RS485 read command to sensor.**
727 )))
728 )))
729
730 (% class="box infomessage" %)
731 (((
732 (((
733 **AT+DATACUTx: Configure how to handle return from RS485 devices.**
734 )))
735 )))
736
737 (((
738
739 )))
740
741 * (((
742 **Downlink Payload:**
743 )))
744
745 (((
746 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
747 )))
748
749 (((
750 (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
751 )))
752
753 (((
754 Format: AF MM NN LL XX XX XX XX YY
755 )))
756
757 (((
758 Where:
759 )))
760
761 * (((
762 MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
763 )))
764 * (((
765 NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
766 )))
767 * (((
768 LL:  The length of AT+COMMAND or AT+DATACUT command
769 )))
770 * (((
771 XX XX XX XX: AT+COMMAND or AT+DATACUT command
772 )))
773 * (((
774 YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
775 )))
776
777 (((
778 **Example:**
779 )))
780
781 (((
782 (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1
783 )))
784
785 (((
786 (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10**
787 )))
788
789 (((
790 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
791 )))
792
793
794
795
796 ==== **Fast command to handle MODBUS device** ====
797
798 (((
799 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
800 )))
801
802 (((
803 This command is valid since v1.3 firmware version
804 )))
805
806 (((
807 AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
808 )))
809
810 (((
811
812 )))
813
814 (((
815 **Example:**
816 )))
817
818 * (((
819 AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
820 )))
821 * (((
822 AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
823 )))
824 * (((
825 AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
826 )))
827
828 [[image:image-20220602165351-6.png]]
829
830 [[image:image-20220602165351-7.png]]
831
832
833
834
835 ==== **RS485 command timeout** ====
836
837 (((
838 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
839 )))
840
841 (((
842 Default value: 0, range:  0 ~~ 65 seconds
843 )))
844
845 * (((
846 **AT Command:**
847 )))
848
849 (% class="box infomessage" %)
850 (((
851 (((
852 **AT+CMDDLaa=hex(bb cc)*1000**
853 )))
854 )))
855
856 (((
857 **Example:**
858 )))
859
860 (((
861 **AT+CMDDL1=1000** to send the open time to 1000ms
862 )))
863
864 (((
865
866 )))
867
868 * (((
869 **Downlink Payload:**
870 )))
871
872 (((
873 **0x AA aa bb cc**
874 )))
875
876 (((
877 Same as: AT+CMDDLaa=hex(bb cc)*1000
878 )))
879
880 (((
881 **Example:**
882 )))
883
884 (((
885 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
886 )))
887
888
889
890
891 ==== **Uplink payload mode** ====
892
893 (((
894 Define to use one uplink or multiple uplinks for the sampling.
895 )))
896
897 (((
898 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
899 )))
900
901 * (((
902 **AT Command:**
903 )))
904
905 (% class="box infomessage" %)
906 (((
907 (((
908 **AT+DATAUP=0**
909 )))
910 )))
911
912 (% class="box infomessage" %)
913 (((
914 (((
915 **AT+DATAUP=1**
916 )))
917 )))
918
919 (((
920
921 )))
922
923 * (((
924 **Downlink Payload:**
925 )))
926
927 (((
928 **0xAD 00**  **~-~->** Same as AT+DATAUP=0
929 )))
930
931 (((
932 **0xAD 01**  **~-~->** Same as AT+DATAUP=1
933 )))
934
935
936
937
938 ==== **Manually trigger an Uplink** ====
939
940 (((
941 Ask device to send an uplink immediately.
942 )))
943
944 * (((
945 **AT Command:**
946 )))
947
948 (((
949 No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
950 )))
951
952 (((
953
954 )))
955
956 * (((
957 **Downlink Payload:**
958 )))
959
960 (((
961 **0x08 FF**, RS485-LN will immediately send an uplink.
962 )))
963
964
965
966
967 ==== **Clear RS485 Command** ====
968
969 (((
970 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
971 )))
972
973 * (((
974 **AT Command:**
975 )))
976
977 (((
978 **AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
979 )))
980
981 (((
982 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
983 )))
984
985 (((
986 Example screen shot after clear all RS485 commands. 
987 )))
988
989 (((
990
991 )))
992
993 (((
994 The uplink screen shot is:
995 )))
996
997 [[image:1654160691922-496.png]]
998
999
1000 * (((
1001 **Downlink Payload:**
1002 )))
1003
1004 (((
1005 **0x09 aa bb** same as AT+CMDEAR=aa,bb
1006 )))
1007
1008
1009
1010
1011 ==== **Set Serial Communication Parameters** ====
1012
1013 (((
1014 Set the Rs485 serial communication parameters:
1015 )))
1016
1017 * (((
1018 **AT Command:**
1019 )))
1020
1021 (((
1022 Set Baud Rate:
1023 )))
1024
1025 (% class="box infomessage" %)
1026 (((
1027 (((
1028 **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1029 )))
1030 )))
1031
1032 (((
1033 Set UART Parity
1034 )))
1035
1036 (% class="box infomessage" %)
1037 (((
1038 (((
1039 **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1040 )))
1041 )))
1042
1043 (((
1044 Set STOPBIT
1045 )))
1046
1047 (% class="box infomessage" %)
1048 (((
1049 (((
1050 **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1051 )))
1052 )))
1053
1054 (((
1055
1056 )))
1057
1058 * (((
1059 **Downlink Payload:**
1060 )))
1061
1062 (((
1063 **A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1064 )))
1065
1066 (((
1067 **Example:**
1068 )))
1069
1070 * (((
1071 A7 01 00 60   same as AT+BAUDR=9600
1072 )))
1073 * (((
1074 A7 01 04 80  same as AT+BAUDR=115200
1075 )))
1076
1077 (((
1078 A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1079 )))
1080
1081 (((
1082 A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1083 )))
1084
1085
1086
1087
1088 == 3.6 Listening mode for RS485 network ==
1089
1090 (((
1091 This feature support since firmware v1.4
1092 )))
1093
1094 (((
1095 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1096 )))
1097
1098 [[image:image-20220602171200-8.png||height="567" width="1007"]]
1099
1100 (((
1101 To enable the listening mode, use can run the command AT+RXMODE.
1102 )))
1103
1104 (((
1105
1106 )))
1107
1108 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1109 |=(% style="width: 100px;" %)(((
1110 **Command example**
1111 )))|=(% style="width: 400px;" %)(((
1112 **Function**
1113 )))
1114 |(% style="width:100px" %)(((
1115 AT+RXMODE=1,10
1116 )))|(% style="width:400px" %)(((
1117 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1118 )))
1119 |(% style="width:100px" %)(((
1120 AT+RXMODE=2,500
1121 )))|(% style="width:400px" %)(((
1122 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1123 )))
1124 |(% style="width:100px" %)(((
1125 AT+RXMODE=0,0
1126 )))|(% style="width:400px" %)(((
1127 Disable listening mode. This is the default settings.
1128 )))
1129 |(% style="width:100px" %)(((
1130
1131 )))|(% style="width:400px" %)(((
1132 A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1133 )))
1134
1135 (((
1136 **Downlink Command:**
1137 )))
1138
1139 (((
1140 **0xA6 aa bb cc ** same as AT+RXMODE=aa,(bb<<8 | cc)
1141 )))
1142
1143 (((
1144
1145 )))
1146
1147 (((
1148 **Example**:
1149 )))
1150
1151 (((
1152 The RS485-LN is set to AT+RXMODE=2,1000
1153 )))
1154
1155 (((
1156 There is a two Modbus commands in the RS485 network as below:
1157 )))
1158
1159 (((
1160 The Modbus master send a command: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b
1161 )))
1162
1163 (((
1164 And Modbus slave reply with: (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
1165 )))
1166
1167 (((
1168 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)01 03 00 00 00 02 c4 0b  (% style="background-color:green" %)01 03 04 00 00 00 00 fa 33
1169 )))
1170
1171 (((
1172 [[image:image-20220602171200-9.png]]
1173 )))
1174
1175 (((
1176
1177 )))
1178
1179 (((
1180 (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1181 )))
1182
1183
1184 == 3.7 Buttons ==
1185
1186
1187 (% border="1" cellspacing="10" style="background-color:#f7faff; width:400px" %)
1188 |=(% style="width: 50px;" %)**Button**|=(% style="width: 350px;" %)**Feature**
1189 |(% style="width:50px" %)**ACT**|(% style="width:350px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1190 |(% style="width:50px" %)**RST**|(% style="width:350px" %)Reboot RS485
1191 |(% style="width:50px" %)**PRO**|(% style="width:350px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1192
1193
1194 == 3.8 LEDs ==
1195
1196
1197 (% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1198 |=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1199 |**PWR**|Always on if there is power
1200 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1201
1202 = 4. Case Study =
1203
1204 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1205
1206
1207 = 5. Use AT Command =
1208
1209 == 5.1 Access AT Command ==
1210
1211 (((
1212 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1213 )))
1214
1215 [[image:1654162355560-817.png]]
1216
1217
1218 (((
1219 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1220 )))
1221
1222 [[image:1654162368066-342.png]]
1223
1224
1225 (((
1226 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1227 )))
1228
1229
1230
1231 == 5.2 Common AT Command Sequence ==
1232
1233 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1234
1235 If device has not joined network yet:
1236
1237 (% class="box infomessage" %)
1238 (((
1239 **AT+FDR**
1240 )))
1241
1242 (% class="box infomessage" %)
1243 (((
1244 **AT+NJM=0**
1245 )))
1246
1247 (% class="box infomessage" %)
1248 (((
1249 **ATZ**
1250 )))
1251
1252
1253 If device already joined network:
1254
1255 (% class="box infomessage" %)
1256 (((
1257 **AT+NJM=0**
1258 )))
1259
1260 (% class="box infomessage" %)
1261 (((
1262 **ATZ**
1263 )))
1264
1265
1266 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1267
1268
1269 (% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1270
1271 (% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode
1272
1273 (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
1274
1275 (% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%)Set Data Rate
1276
1277 (% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1278
1279 (% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz
1280
1281 (% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1282
1283 (% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1284
1285 (% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1286
1287 (% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1288
1289
1290 (% style="color:red" %)**Note:**
1291
1292 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1293 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1294 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1295 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1296
1297 [[image:1654162478620-421.png]]
1298
1299
1300 = 6. FAQ =
1301
1302 == 6.1 How to upgrade the image? ==
1303
1304 (((
1305 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1306 )))
1307
1308 * (((
1309 Support new features
1310 )))
1311 * (((
1312 For bug fix
1313 )))
1314 * (((
1315 Change LoRaWAN bands.
1316 )))
1317
1318 (((
1319 Below shows the hardware connection for how to upload an image to RS485-LN:
1320 )))
1321
1322 [[image:1654162535040-878.png]]
1323
1324 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1325
1326 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1327
1328 **Step3: **Open flashloader; choose the correct COM port to update.
1329
1330 (((
1331 (((
1332 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1333 )))
1334 )))
1335
1336
1337 [[image:image-20220602175818-12.png]]
1338
1339
1340 [[image:image-20220602175848-13.png]]
1341
1342
1343 [[image:image-20220602175912-14.png]]
1344
1345
1346 **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1347
1348 [[image:image-20220602175638-10.png]]
1349
1350
1351 == 6.2 How to change the LoRa Frequency Bands/Region? ==
1352
1353 User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1354
1355
1356 == 6.3 How many RS485-Slave can RS485-BL connects? ==
1357
1358 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1359
1360
1361 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
1362
1363 When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1364
1365 Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1366
1367
1368 = 7. Trouble Shooting =
1369
1370 == 7.1 Downlink doesn’t work, how to solve it? ==
1371
1372 Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1373
1374
1375 == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1376
1377 It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1378
1379
1380 = 8. Order Info =
1381
1382 (% style="color:blue" %)**Part Number: RS485-LN-XXX**
1383
1384 (% style="color:blue" %)**XXX:**
1385
1386 * (% style="color:blue" %)**EU433**(%%): frequency bands EU433
1387 * (% style="color:blue" %)**EU868**(%%): frequency bands EU868
1388 * (% style="color:blue" %)**KR920**(%%): frequency bands KR920
1389 * (% style="color:blue" %)**CN470**(%%): frequency bands CN470
1390 * (% style="color:blue" %)**AS923**(%%): frequency bands AS923
1391 * (% style="color:blue" %)**AU915**(%%): frequency bands AU915
1392 * (% style="color:blue" %)**US915**(%%): frequency bands US915
1393 * (% style="color:blue" %)**IN865**(%%): frequency bands IN865
1394 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1395 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1396
1397 = 9.Packing Info =
1398
1399
1400 **Package Includes**:
1401
1402 * RS485-LN x 1
1403 * Stick Antenna for LoRa RF part x 1
1404 * Program cable x 1
1405
1406 **Dimension and weight**:
1407
1408 * Device Size: 13.5 x 7 x 3 cm
1409 * Device Weight: 105g
1410 * Package Size / pcs : 14.5 x 8 x 5 cm
1411 * Weight / pcs : 170g
1412
1413 = 10. FCC Caution for RS485LN-US915 =
1414
1415 (((
1416 Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1417 )))
1418
1419 (((
1420 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1421 )))
1422
1423 (((
1424
1425 )))
1426
1427 (((
1428 **IMPORTANT NOTE:**
1429 )))
1430
1431 (((
1432 **Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1433 )))
1434
1435 (((
1436 —Reorient or relocate the receiving antenna.
1437 )))
1438
1439 (((
1440 —Increase the separation between the equipment and receiver.
1441 )))
1442
1443 (((
1444 —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
1445 )))
1446
1447 (((
1448 —Consult the dealer or an experienced radio/TV technician for help.
1449 )))
1450
1451 (((
1452
1453 )))
1454
1455 (((
1456 **FCC Radiation Exposure Statement:**
1457 )))
1458
1459 (((
1460 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
1461 )))
1462
1463
1464 = 11. Support =
1465
1466 * (((
1467 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1468 )))
1469 * (((
1470 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
1471 )))
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0