Show last authors
1 (% style="text-align:center" %)
2 [[image:1653266934636-343.png||height="385" width="385"]]
3
4
5
6 **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7
8
9 **Table of Contents:**
10
11
12
13
14
15 = 1.Introduction =
16
17 == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
18
19 (((
20 (((
21 The Dragino RS485-LN is a RS485 to LoRaWAN Converter. It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
22 )))
23
24 (((
25 RS485-LN allows user to monitor / control RS485 devices and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
26 )))
27
28 (((
29 For data uplink, RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server.
30 )))
31
32 (((
33 For data downlink, RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices.
34 )))
35 )))
36
37 [[image:1653267211009-519.png||height="419" width="724"]]
38
39 == 1.2 Specifications ==
40
41 **Hardware System:**
42
43 * STM32L072CZT6 MCU
44 * SX1276/78 Wireless Chip 
45 * Power Consumption (exclude RS485 device):
46 ** Idle: 32mA@12v
47
48 *
49 ** 20dB Transmit: 65mA@12v
50
51 **Interface for Model:**
52
53 * RS485
54 * Power Input 7~~ 24V DC. 
55
56 **LoRa Spec:**
57
58 * Frequency Range:
59 ** Band 1 (HF): 862 ~~ 1020 Mhz
60 ** Band 2 (LF): 410 ~~ 528 Mhz
61 * 168 dB maximum link budget.
62 * +20 dBm - 100 mW constant RF output vs.
63 * +14 dBm high efficiency PA.
64 * Programmable bit rate up to 300 kbps.
65 * High sensitivity: down to -148 dBm.
66 * Bullet-proof front end: IIP3 = -12.5 dBm.
67 * Excellent blocking immunity.
68 * Low RX current of 10.3 mA, 200 nA register retention.
69 * Fully integrated synthesizer with a resolution of 61 Hz.
70 * FSK, GFSK, MSK, GMSK, LoRaTM and OOK modulation.
71 * Built-in bit synchronizer for clock recovery.
72 * Preamble detection.
73 * 127 dB Dynamic Range RSSI.
74 * Automatic RF Sense and CAD with ultra-fast AFC.
75 * Packet engine up to 256 bytes with CRC.
76
77 == 1.3 Features ==
78
79 * LoRaWAN Class A & Class C protocol (default Class C)
80 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
81 * AT Commands to change parameters
82 * Remote configure parameters via LoRa Downlink
83 * Firmware upgradable via program port
84 * Support multiply RS485 devices by flexible rules
85 * Support Modbus protocol
86 * Support Interrupt uplink (Since hardware version v1.2)
87
88 == 1.4 Applications ==
89
90 * Smart Buildings & Home Automation
91 * Logistics and Supply Chain Management
92 * Smart Metering
93 * Smart Agriculture
94 * Smart Cities
95 * Smart Factory
96
97 == 1.5 Firmware Change log ==
98
99 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
100
101 == 1.6 Hardware Change log ==
102
103 (((
104 (((
105 v1.2: Add External Interrupt Pin.
106
107 v1.0: Release
108 )))
109 )))
110
111 = 2. Power ON Device =
112
113 (((
114 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
115
116 * Power Source VIN to RS485-LN VIN+
117 * Power Source GND to RS485-LN VIN-
118
119 (((
120 Once there is power, the RS485-LN will be on.
121 )))
122
123 [[image:1653268091319-405.png]]
124 )))
125
126 = 3. Operation Mode =
127
128 == 3.1 How it works? ==
129
130 (((
131 The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
132 )))
133
134 == 3.2 Example to join LoRaWAN network ==
135
136 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
137
138 [[image:1653268155545-638.png||height="334" width="724"]]
139
140 (((
141 The RS485-LN in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. The connection is as below:
142
143 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
144
145 [[image:1653268227651-549.png||height="592" width="720"]]
146
147 (((
148 The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3:
149 )))
150
151 (((
152 **Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN.
153 )))
154
155 (((
156 Each RS485-LN is shipped with a sticker with unique device EUI:
157 )))
158 )))
159
160 [[image:1652953462722-299.png]]
161
162 (((
163 (((
164 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
165 )))
166
167 (((
168 Add APP EUI in the application.
169 )))
170 )))
171
172 [[image:image-20220519174512-1.png]]
173
174 [[image:image-20220519174512-2.png||height="323" width="720"]]
175
176 [[image:image-20220519174512-3.png||height="556" width="724"]]
177
178 [[image:image-20220519174512-4.png]]
179
180 You can also choose to create the device manually.
181
182 [[image:1652953542269-423.png||height="710" width="723"]]
183
184 Add APP KEY and DEV EUI
185
186 [[image:1652953553383-907.png||height="514" width="724"]]
187
188
189 (((
190 **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
191 )))
192
193 [[image:1652953568895-172.png||height="232" width="724"]]
194
195 == 3.3 Configure Commands to read data ==
196
197 (((
198 (((
199 There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
200 )))
201
202 (((
203 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
204 )))
205 )))
206
207 === 3.3.1 onfigure UART settings for RS485 or TTL communication ===
208
209 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
210
211 (% border="1" style="background-color:#ffffcc; color:green; width:795px" %)
212 |(((
213 **AT Commands**
214 )))|(% style="width:285px" %)(((
215 **Description**
216 )))|(% style="width:347px" %)(((
217 **Example**
218 )))
219 |(((
220 AT+BAUDR
221 )))|(% style="width:285px" %)(((
222 Set the baud rate (for RS485 connection). Default Value is: 9600.
223 )))|(% style="width:347px" %)(((
224 (((
225 AT+BAUDR=9600
226 )))
227
228 (((
229 Options: (1200,2400,4800,14400,19200,115200)
230 )))
231 )))
232 |(((
233 AT+PARITY
234 )))|(% style="width:285px" %)(((
235 Set UART parity (for RS485 connection)
236 )))|(% style="width:347px" %)(((
237 (((
238 AT+PARITY=0
239 )))
240
241 (((
242 Option: 0: no parity, 1: odd parity, 2: even parity
243 )))
244 )))
245 |(((
246 AT+STOPBIT
247 )))|(% style="width:285px" %)(((
248 (((
249 Set serial stopbit (for RS485 connection)
250 )))
251
252 (((
253
254 )))
255 )))|(% style="width:347px" %)(((
256 (((
257 AT+STOPBIT=0 for 1bit
258 )))
259
260 (((
261 AT+STOPBIT=1 for 1.5 bit
262 )))
263
264 (((
265 AT+STOPBIT=2 for 2 bits
266 )))
267 )))
268
269 === 3.3.2 Configure sensors ===
270
271 (((
272 (((
273 Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won’t run during each sampling.
274 )))
275 )))
276
277 (% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
278 |**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
279 |AT+CFGDEV|(% style="width:418px" %)(((
280 This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
281
282 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
283
284 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
285 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
286
287 === 3.3.3 Configure read commands for each sampling ===
288
289 (((
290 RS485-BL is a battery powered device; it will sleep most of time. And wake up on each period and read RS485 / TTL sensor data and uplink.
291 )))
292
293 (((
294 During each sampling, we need to confirm what commands we need to send to the sensors to read data. After the RS485/TTL sensors send back the value, it normally includes some bytes and we only need a few from them for a shorten payload.
295 )))
296
297 (((
298 To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload.
299 )))
300
301 (((
302 This section describes how to achieve above goals.
303 )))
304
305 (((
306 During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
307 )))
308
309 (((
310 **Command from RS485-BL to Sensor:**
311 )))
312
313 (((
314 RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar.
315 )))
316
317 (((
318 **Handle return from sensors to RS485-BL**:
319 )))
320
321 (((
322 After RS485-BL send out a string to sensor, RS485-BL will wait for the return from RS485 or TTL sensor. And user can specify how to handle the return, by **AT+DATACUT or AT+SEARCH commands**
323 )))
324
325 * (((
326 **AT+DATACUT**
327 )))
328
329 (((
330 When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command.
331 )))
332
333 * (((
334 **AT+SEARCH**
335 )))
336
337 (((
338 When the return value from sensor is dynamic length and we are not sure which bytes the valid data is, instead, we know what value the valid value following. We can use AT+SEARCH to search the valid value in the return string.
339 )))
340
341 (((
342 **Define wait timeout:**
343 )))
344
345 (((
346 Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example, AT+CMDDL1=1000 to send the open time to 1000ms
347 )))
348
349 (((
350 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
351 )))
352
353 **Examples:**
354
355 Below are examples for the how above AT Commands works.
356
357 **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
358
359 (% border="1" class="table-bordered" %)
360 |(((
361 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
362
363 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
364
365 **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command**
366 )))
367
368 (((
369 For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually.
370 )))
371
372 (((
373 In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
374 )))
375
376 (((
377 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
378 )))
379
380 (% border="1" class="table-bordered" %)
381 |(((
382 **AT+SEARCHx=aa,xx xx xx xx xx**
383
384 * **aa: 1: prefix match mode; 2: prefix and suffix match mode**
385 * **xx xx xx xx xx: match string. Max 5 bytes for prefix and 5 bytes for suffix**
386
387
388 )))
389
390 **Examples:**
391
392 ~1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
393
394 If we set AT+SEARCH1=1,1E 56 34.      (max 5 bytes for prefix)
395
396 The valid data will be all bytes after 1E 56 34 , so it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30 31 00 49**
397
398 [[image:1653269403619-508.png]]
399
400 2. For a return string from AT+COMMAND1:  16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
401
402 If we set AT+SEARCH1=2, 1E 56 34+31 00 49
403
404 Device will search the bytes between 1E 56 34 and 31 00 49. So it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30**
405
406 [[image:1653269438444-278.png]]
407
408 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
409
410 |(((
411 **AT+DATACUTx=a,b,c**
412
413 * **a: length for the return of AT+COMMAND**
414 * **b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.**
415 * **c: define the position for valid value.  **
416 )))
417
418 Examples:
419
420 * Grab bytes:
421
422 [[image:1653269551753-223.png||height="311" width="717"]]
423
424 * Grab a section.
425
426 [[image:1653269568276-930.png||height="325" width="718"]]
427
428 * Grab different sections.
429
430 [[image:1653269593172-426.png||height="303" width="725"]]
431
432 (% style="color:red" %)**Note:**
433
434 AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0.
435
436 Example:
437
438 (% style="color:red" %)AT+COMMAND1=11 01 1E D0,0
439
440 (% style="color:red" %)AT+SEARCH1=1,1E 56 34
441
442 (% style="color:red" %)AT+DATACUT1=0,2,1~~5
443
444 (% style="color:red" %)Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
445
446 (% style="color:red" %)String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49
447
448 (% style="color:red" %)Valid payload after DataCUT command: 2e 30 58 5f 36
449
450 [[image:1653269618463-608.png]]
451
452 === 3.3.4 Compose the uplink payload ===
453
454 (((
455 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
456 )))
457
458 (((
459 (% style="color:#4f81bd" %)**Examples: AT+DATAUP=0**
460 )))
461
462 (((
463 Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**A SIGNLE UPLINK**.
464 )))
465
466 (((
467 Final Payload is
468 )))
469
470 (((
471 (% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx**
472 )))
473
474 (((
475 Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
476 )))
477
478 [[image:1653269759169-150.png||height="513" width="716"]]
479
480 (% style="color:#4f81bd" %)**Examples: AT+DATAUP=1**
481
482 Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**Multiply UPLINKs**.
483
484 Final Payload is
485
486 (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
487
488 1. Battery Info (2 bytes): Battery voltage
489 1. PAYVER (1 byte): Defined by AT+PAYVER
490 1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
491 1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
492 1. DATA: Valid value: max 6 bytes(US915 version here, Notice*!) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes
493
494 [[image:1653269916228-732.png||height="433" width="711"]]
495
496
497 So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA
498
499 DATA1=RETURN1 Valid Value = (% style="background-color:green; color:white" %)20 20 0a 33 90 41
500
501 DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10=(% style="background-color:green; color:white" %) 02 aa 05 81 0a 20
502
503 DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 = (% style="background-color:green; color:white" %)20 20 20 2d 30
504
505 Below are the uplink payloads:
506
507 [[image:1653270130359-810.png]]
508
509
510 (% style="color:red" %)**Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:**
511
512 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
513
514 * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
515
516 * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
517
518 ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
519
520 === 3.3.5 Uplink on demand ===
521
522 Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command.
523
524 Downlink control command:
525
526 [[0x08 command>>path:#downlink_08]]: Poll an uplink with current command set in RS485-BL.
527
528 [[0xA8 command>>path:#downlink_A8]]: Send a command to RS485-BL and uplink the output from sensors.
529
530
531
532 1.
533 11.
534 111. Uplink on Interrupt
535
536 Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
537
538 AT+INTMOD=0  Disable Interrupt
539
540 AT+INTMOD=1  Interrupt trigger by rising or falling edge.
541
542 AT+INTMOD=2  Interrupt trigger by falling edge. ( Default Value)
543
544 AT+INTMOD=3  Interrupt trigger by rising edge.
545
546
547 1.
548 11. Uplink Payload
549
550 |**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands**
551 |Value|(((
552 Battery(mV)
553
554 &
555
556 Interrupt _Flag
557 )))|(((
558 PAYLOAD_VER
559
560
561 )))|If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
562
563 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
564
565
566 function Decoder(bytes, port) {
567
568 ~/~/Payload Formats of RS485-BL Deceive
569
570 return {
571
572 ~/~/Battery,units:V
573
574 BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,
575
576 ~/~/GPIO_EXTI 
577
578 EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",
579
580 ~/~/payload of version
581
582 Pay_ver:bytes[2],
583
584 };
585
586 }
587
588
589
590
591
592
593
594 TTN V3 uplink screen shot.
595
596 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
597
598 1.
599 11. Configure RS485-BL via AT or Downlink
600
601 User can configure RS485-BL via [[AT Commands >>path:#_​Using_the_AT]]or LoRaWAN Downlink Commands
602
603 There are two kinds of Commands:
604
605 * **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
606
607 * **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
608
609 1.
610 11.
611 111. Common Commands:
612
613 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
614
615
616 1.
617 11.
618 111. Sensor related commands:
619
620 ==== Choose Device Type (RS485 or TTL) ====
621
622 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
623
624 * AT Command
625
626 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
627
628 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
629
630
631 * Downlink Payload
632
633 **0A aa**     à same as AT+MOD=aa
634
635
636
637 ==== [[RS485 Debug Command>>path:#downlink_A8]] (AT+CFGDEV) ====
638
639 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling.
640
641 * AT Command
642
643 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
644
645 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
646
647
648
649 * Downlink Payload
650
651 Format: A8 MM NN XX XX XX XX YY
652
653 Where:
654
655 * MM: 1: add CRC-16/MODBUS ; 0: no CRC
656 * NN: The length of RS485 command
657 * XX XX XX XX: RS485 command total NN bytes
658 * YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
659
660 **Example 1:**
661
662 To connect a Modbus Alarm with below commands.
663
664 * The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
665
666 * The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
667
668 So if user want to use downlink command to control to RS485 Alarm, he can use:
669
670 **A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm
671
672 **A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm
673
674 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
675
676
677 **Example 2:**
678
679 Check TTL Sensor return:
680
681 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
682
683
684
685
686 ==== Set Payload version ====
687
688 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
689
690 * AT Command:
691
692 AT+PAYVER: Set PAYVER field = 1
693
694
695 * Downlink Payload:
696
697 0xAE 01   à Set PAYVER field =  0x01
698
699 0xAE 0F   à Set PAYVER field =  0x0F
700
701
702 ==== Set RS485 Sampling Commands ====
703
704 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
705
706 These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]].
707
708
709 * AT Command:
710
711 AT+COMMANDx: Configure RS485 read command to sensor.
712
713 AT+DATACUTx: Configure how to handle return from RS485 devices.
714
715 AT+SEARCHx: Configure search command
716
717
718 * Downlink Payload:
719
720 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
721
722 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
723
724 Format: AF MM NN LL XX XX XX XX YY
725
726 Where:
727
728 * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
729 * NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
730 * LL: The length of AT+COMMAND or AT+DATACUT command
731 * XX XX XX XX: AT+COMMAND or AT+DATACUT command
732 * YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
733
734 Example:
735
736 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
737
738 **AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10**
739
740 **AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10**
741
742
743 0xAB downlink command can be used for set AT+SEARCHx
744
745 Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
746
747 * AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
748 * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
749
750 **AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
751
752
753 ==== Fast command to handle MODBUS device ====
754
755 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
756
757 This command is valid since v1.3 firmware version
758
759
760 AT+MBFUN has only two value:
761
762 * AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return
763
764 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
765
766 * AT+MBFUN=0: Disable Modbus fast reading.
767
768 Example:
769
770 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
771 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
772 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
773
774 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
775
776
777 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
778
779
780 * Downlink Commands:
781
782 A9 aa -à Same as AT+MBFUN=aa
783
784
785 ==== RS485 command timeout ====
786
787 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
788
789 Default value: 0, range:  0 ~~ 5 seconds
790
791
792 * AT Command:
793
794 AT+CMDDLaa=hex(bb cc)
795
796 Example:
797
798 **AT+CMDDL1=1000** to send the open time to 1000ms
799
800
801 * Downlink Payload:
802
803 0x AA aa bb cc
804
805 Same as: AT+CMDDLaa=hex(bb cc)
806
807 Example:
808
809 0xAA 01 03 E8  à Same as **AT+CMDDL1=1000 ms**
810
811
812 ==== [[Uplink>>path:#downlink_A8]] payload mode ====
813
814 Define to use one uplink or multiple uplinks for the sampling.
815
816 The use of this command please see: [[Compose Uplink payload>>path:#DataUP]]
817
818 * AT Command:
819
820 AT+DATAUP=0
821
822 AT+DATAUP=1
823
824
825 * Downlink Payload:
826
827 0xAD 00   à Same as AT+DATAUP=0
828
829 0xAD 01   à Same as AT+DATAUP=1
830
831
832 ==== Manually trigger an Uplink ====
833
834 Ask device to send an uplink immediately.
835
836 * Downlink Payload:
837
838 0x08 FF, RS485-BL will immediately send an uplink.
839
840
841 ==== Clear RS485 Command ====
842
843 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
844
845
846 * AT Command:
847
848 **AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
849
850 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
851
852 Example screen shot after clear all RS485 commands. 
853
854
855
856 The uplink screen shot is:
857
858 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
859
860
861 * Downlink Payload:
862
863 0x09 aa bb same as AT+CMDEAR=aa,bb
864
865
866 ==== Set Serial Communication Parameters ====
867
868 Set the Rs485 serial communication parameters:
869
870 * AT Command:
871
872 Set Baud Rate:
873
874 AT+BAUDR=9600    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
875
876
877 Set UART parity
878
879 AT+PARITY=0    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
880
881
882 Set STOPBIT
883
884 AT+STOPBIT=0    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
885
886
887 * Downlink Payload:
888
889 A7 01 aa bb: Same  AT+BAUDR=hex(aa bb)*100
890
891 Example:
892
893 * A7 01 00 60   same as AT+BAUDR=9600
894 * A7 01 04 80  same as AT+BAUDR=115200
895
896 A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
897
898 A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
899
900
901 ==== Control output power duration ====
902
903 User can set the output power duration before each sampling.
904
905 * AT Command:
906
907 Example:
908
909 AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling.
910
911 AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling.
912
913
914 * LoRaWAN Downlink Command:
915
916 07 01 aa bb  Same as AT+5VT=(aa bb)
917
918 07 02 aa bb  Same as AT+3V3T=(aa bb)
919
920
921
922
923 1.
924 11. Buttons
925
926 |**Button**|**Feature**
927 |**RST**|Reboot RS485-BL
928
929 1.
930 11. +3V3 Output
931
932 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
933
934 The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 
935
936
937 The +3V3 output time can be controlled by AT Command.
938
939 **AT+3V3T=1000**
940
941 Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
942
943
944 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
945
946
947 1.
948 11. +5V Output
949
950 RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
951
952 The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 
953
954
955 The 5V output time can be controlled by AT Command.
956
957 **AT+5VT=1000**
958
959 Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors.
960
961
962 By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor.
963
964
965
966
967 1.
968 11. LEDs
969
970 |**LEDs**|**Feature**
971 |**LED1**|Blink when device transmit a packet.
972
973 1.
974 11. Switch Jumper
975
976 |**Switch Jumper**|**Feature**
977 |**SW1**|(((
978 ISP position: Upgrade firmware via UART
979
980 Flash position: Configure device, check running status.
981 )))
982 |**SW2**|(((
983 5V position: set to compatible with 5v I/O.
984
985 3.3v position: set to compatible with 3.3v I/O.,
986 )))
987
988 +3.3V: is always ON
989
990 +5V: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
991
992 1. Case Study
993
994 User can check this URL for some case studies.
995
996 [[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]
997
998
999
1000
1001 1. Use AT Command
1002 11. Access AT Command
1003
1004 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1005
1006 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1007
1008
1009 In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1010
1011 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1012
1013
1014
1015 More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1016
1017
1018
1019 1.
1020 11. Common AT Command Sequence
1021 111. Multi-channel ABP mode (Use with SX1301/LG308)
1022
1023 If device has not joined network yet:
1024
1025 AT+FDR
1026
1027 AT+NJM=0
1028
1029 ATZ
1030
1031
1032 If device already joined network:
1033
1034 AT+NJM=0
1035
1036 ATZ
1037
1038 1.
1039 11.
1040 111. Single-channel ABP mode (Use with LG01/LG02)
1041
1042 AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1043
1044 AT+NJM=0 Set to ABP mode
1045
1046 AT+ADR=0 Set the Adaptive Data Rate Off
1047
1048 AT+DR=5  Set Data Rate
1049
1050 AT+TDC=60000  Set transmit interval to 60 seconds
1051
1052 AT+CHS=868400000 Set transmit frequency to 868.4Mhz
1053
1054 AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
1055
1056 AT+RX2DR=5  Set RX2DR to match the downlink DR from server. see below
1057
1058 AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1059
1060 ATZ          Reset MCU
1061
1062 **Note:**
1063
1064 1. Make sure the device is set to ABP mode in the IoT Server.
1065 1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1066 1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1067 1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1068
1069 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
1070
1071
1072 1. FAQ
1073 11. How to upgrade the image?
1074
1075 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to:
1076
1077 * Support new features
1078 * For bug fix
1079 * Change LoRaWAN bands.
1080
1081 Below shows the hardware connection for how to upload an image to RS485-BL:
1082
1083 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]
1084
1085 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1086
1087 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1088
1089 **Step3: **Open flashloader; choose the correct COM port to update.
1090
1091
1092 |(((
1093 HOLD PRO then press the RST button, SYS will be ON, then click next
1094 )))
1095
1096 |(((
1097 Board detected
1098 )))
1099
1100 |(((
1101
1102 )))
1103
1104 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]]
1105
1106
1107
1108 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]]
1109
1110
1111 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1112
1113
1114 1.
1115 11. How to change the LoRa Frequency Bands/Region?
1116
1117 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
1118
1119
1120
1121 1.
1122 11. How many RS485-Slave can RS485-BL connects?
1123
1124 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
1125
1126
1127
1128
1129 1. Trouble Shooting     
1130 11. Downlink doesn’t work, how to solve it?
1131
1132 Please see this link for debug:
1133
1134 [[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 
1135
1136
1137
1138 1.
1139 11. Why I can’t join TTN V3 in US915 /AU915 bands?
1140
1141 It might about the channels mapping. Please see for detail.
1142
1143 [[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]]
1144
1145
1146
1147 1. Order Info
1148
1149 **Part Number: RS485-BL-XXX**
1150
1151 **XXX:**
1152
1153 * **EU433**: frequency bands EU433
1154 * **EU868**: frequency bands EU868
1155 * **KR920**: frequency bands KR920
1156 * **CN470**: frequency bands CN470
1157 * **AS923**: frequency bands AS923
1158 * **AU915**: frequency bands AU915
1159 * **US915**: frequency bands US915
1160 * **IN865**: frequency bands IN865
1161 * **RU864**: frequency bands RU864
1162 * **KZ865: **frequency bands KZ865
1163
1164 1. Packing Info
1165
1166 **Package Includes**:
1167
1168 * RS485-BL x 1
1169 * Stick Antenna for LoRa RF part x 1
1170 * Program cable x 1
1171
1172 **Dimension and weight**:
1173
1174 * Device Size: 13.5 x 7 x 3 cm
1175 * Device Weight: 105g
1176 * Package Size / pcs : 14.5 x 8 x 5 cm
1177 * Weight / pcs : 170g
1178
1179 1. Support
1180
1181 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1182 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
1183
1184 [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved