Version 22.2 by Xiaoling on 2022/05/23 09:11

Show last authors
1 (% style="text-align:center" %)
2 [[image:1653266934636-343.png||height="385" width="385"]]
3
4
5
6 **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7
8
9 **Table of Contents:**
10
11
12
13
14
15 = 1.Introduction =
16
17 == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
18
19 (((
20 (((
21 The Dragino RS485-LN is a RS485 to LoRaWAN Converter. It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
22 )))
23
24 (((
25 RS485-LN allows user to monitor / control RS485 devices and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
26 )))
27
28 (((
29 For data uplink, RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server.
30 )))
31
32 (((
33 For data downlink, RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices.
34 )))
35 )))
36
37 [[image:1653267211009-519.png||height="419" width="724"]]
38
39 == 1.2 Specifications ==
40
41 **Hardware System:**
42
43 * STM32L072CZT6 MCU
44 * SX1276/78 Wireless Chip
45 * Power Consumption (exclude RS485 device):
46 ** Idle: 32mA@12v
47
48 *
49 ** 20dB Transmit: 65mA@12v
50
51 **Interface for Model:**
52
53 * RS485
54 * Power Input 7~~ 24V DC.
55
56 **LoRa Spec:**
57
58 * Frequency Range:
59 ** Band 1 (HF): 862 ~~ 1020 Mhz
60 ** Band 2 (LF): 410 ~~ 528 Mhz
61 * 168 dB maximum link budget.
62 * +20 dBm - 100 mW constant RF output vs.
63 * +14 dBm high efficiency PA.
64 * Programmable bit rate up to 300 kbps.
65 * High sensitivity: down to -148 dBm.
66 * Bullet-proof front end: IIP3 = -12.5 dBm.
67 * Excellent blocking immunity.
68 * Low RX current of 10.3 mA, 200 nA register retention.
69 * Fully integrated synthesizer with a resolution of 61 Hz.
70 * FSK, GFSK, MSK, GMSK, LoRaTM and OOK modulation.
71 * Built-in bit synchronizer for clock recovery.
72 * Preamble detection.
73 * 127 dB Dynamic Range RSSI.
74 * Automatic RF Sense and CAD with ultra-fast AFC.
75 * Packet engine up to 256 bytes with CRC.
76
77 == 1.3 Features ==
78
79 * LoRaWAN Class A & Class C protocol (default Class C)
80 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
81 * AT Commands to change parameters
82 * Remote configure parameters via LoRa Downlink
83 * Firmware upgradable via program port
84 * Support multiply RS485 devices by flexible rules
85 * Support Modbus protocol
86 * Support Interrupt uplink (Since hardware version v1.2)
87
88 == 1.4 Applications ==
89
90 * Smart Buildings & Home Automation
91 * Logistics and Supply Chain Management
92 * Smart Metering
93 * Smart Agriculture
94 * Smart Cities
95 * Smart Factory
96
97 == 1.5 Firmware Change log ==
98
99 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
100
101 == 1.6 Hardware Change log ==
102
103 (((
104 (((
105 v1.2: Add External Interrupt Pin.
106
107 v1.0: Release
108 )))
109 )))
110
111 = 2. Power ON Device =
112
113 (((
114 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
115
116 * Power Source VIN to RS485-LN VIN+
117 * Power Source GND to RS485-LN VIN-
118
119 (((
120 Once there is power, the RS485-LN will be on.
121 )))
122
123 [[image:1653268091319-405.png]]
124 )))
125
126 = 3. Operation Mode =
127
128 == 3.1 How it works? ==
129
130 (((
131 The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
132 )))
133
134 == 3.2 Example to join LoRaWAN network ==
135
136 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
137
138 [[image:1653268155545-638.png||height="334" width="724"]]
139
140 (((
141 The RS485-LN in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. The connection is as below:
142
143 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
144
145 [[image:1653268227651-549.png||height="592" width="720"]]
146
147 (((
148 The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3:
149 )))
150
151 (((
152 **Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN.
153 )))
154
155 (((
156 Each RS485-LN is shipped with a sticker with unique device EUI:
157 )))
158 )))
159
160 [[image:1652953462722-299.png]]
161
162 (((
163 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
164 )))
165
166 (((
167 Add APP EUI in the application.
168 )))
169
170
171
172
173 [[image:image-20220519174512-1.png]]
174
175 [[image:image-20220519174512-2.png||height="328" width="731"]]
176
177 [[image:image-20220519174512-3.png||height="556" width="724"]]
178
179 [[image:image-20220519174512-4.png]]
180
181 You can also choose to create the device manually.
182
183 [[image:1652953542269-423.png||height="710" width="723"]]
184
185 Add APP KEY and DEV EUI
186
187 [[image:1652953553383-907.png||height="514" width="724"]]
188
189
190 (((
191 **Step 2**: Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
192 )))
193
194 [[image:1652953568895-172.png||height="232" width="724"]]
195
196 == 3.3 Configure Commands to read data ==
197
198 (((
199 There are plenty of RS485 and TTL level devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-BL supports flexible command set. User can use [[AT Commands or LoRaWAN Downlink>>path:#AT_COMMAND]] Command to configure how RS485-BL should read the sensor and how to handle the return from RS485 or TTL sensors.
200 )))
201
202 === 3.3.1 onfigure UART settings for RS485 or TTL communication ===
203
204 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
205
206 **~1. RS485-MODBUS mode:**
207
208 AT+MOD=1 ~/~/ Support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
209
210 **2. TTL mode:**
211
212 AT+MOD=2 ~/~/ Support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
213
214 RS485-BL default UART settings is **9600, no parity, stop bit 1**. If the sensor has a different settings, user can change the RS485-BL setting to match.
215
216 (% border="1" style="background-color:#ffffcc; color:green; width:795px" %)
217 |(((
218 **AT Commands**
219 )))|(% style="width:285px" %)(((
220 **Description**
221 )))|(% style="width:347px" %)(((
222 **Example**
223 )))
224 |(((
225 AT+BAUDR
226 )))|(% style="width:285px" %)(((
227 Set the baud rate (for RS485 connection). Default Value is: 9600.
228 )))|(% style="width:347px" %)(((
229 (((
230 AT+BAUDR=9600
231 )))
232
233 (((
234 Options: (1200,2400,4800,14400,19200,115200)
235 )))
236 )))
237 |(((
238 AT+PARITY
239 )))|(% style="width:285px" %)(((
240 (((
241 Set UART parity (for RS485 connection)
242 )))
243
244 (((
245 Default Value is: no parity.
246 )))
247 )))|(% style="width:347px" %)(((
248 (((
249 AT+PARITY=0
250 )))
251
252 (((
253 Option: 0: no parity, 1: odd parity, 2: even parity
254 )))
255 )))
256 |(((
257 AT+STOPBIT
258 )))|(% style="width:285px" %)(((
259 (((
260 Set serial stopbit (for RS485 connection)
261 )))
262
263 (((
264 Default Value is: 1bit.
265 )))
266 )))|(% style="width:347px" %)(((
267 (((
268 AT+STOPBIT=0 for 1bit
269 )))
270
271 (((
272 AT+STOPBIT=1 for 1.5 bit
273 )))
274
275 (((
276 AT+STOPBIT=2 for 2 bits
277 )))
278 )))
279
280 === 3.3.2 Configure sensors ===
281
282 (((
283 Some sensors might need to configure before normal operation. User can configure such sensor via PC or through RS485-BL AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**.
284 )))
285
286 (((
287 When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling.
288 )))
289
290 (% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
291 |**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
292 |AT+CFGDEV|(% style="width:418px" %)(((
293 This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
294
295 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
296
297 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
298 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
299
300 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>path:#AT_CFGDEV]].
301
302 === 3.3.3 Configure read commands for each sampling ===
303
304 (((
305 RS485-BL is a battery powered device; it will sleep most of time. And wake up on each period and read RS485 / TTL sensor data and uplink.
306 )))
307
308 (((
309 During each sampling, we need to confirm what commands we need to send to the sensors to read data. After the RS485/TTL sensors send back the value, it normally includes some bytes and we only need a few from them for a shorten payload.
310 )))
311
312 (((
313 To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload.
314 )))
315
316 (((
317 This section describes how to achieve above goals.
318 )))
319
320 (((
321 During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
322 )))
323
324 (((
325 **Command from RS485-BL to Sensor:**
326 )))
327
328 (((
329 RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar.
330 )))
331
332 (((
333 **Handle return from sensors to RS485-BL**:
334 )))
335
336 (((
337 After RS485-BL send out a string to sensor, RS485-BL will wait for the return from RS485 or TTL sensor. And user can specify how to handle the return, by **AT+DATACUT or AT+SEARCH commands**
338 )))
339
340 * (((
341 **AT+DATACUT**
342 )))
343
344 (((
345 When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command.
346 )))
347
348 * (((
349 **AT+SEARCH**
350 )))
351
352 (((
353 When the return value from sensor is dynamic length and we are not sure which bytes the valid data is, instead, we know what value the valid value following. We can use AT+SEARCH to search the valid value in the return string.
354 )))
355
356 (((
357 **Define wait timeout:**
358 )))
359
360 (((
361 Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example, AT+CMDDL1=1000 to send the open time to 1000ms
362 )))
363
364 (((
365 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
366 )))
367
368 **Examples:**
369
370 Below are examples for the how above AT Commands works.
371
372 **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
373
374 (% border="1" class="table-bordered" %)
375 |(((
376 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
377
378 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
379
380 **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command**
381 )))
382
383 For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually.
384
385 In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
386
387 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
388
389 (% border="1" class="table-bordered" %)
390 |(((
391 **AT+SEARCHx=aa,xx xx xx xx xx**
392
393 * **aa: 1: prefix match mode; 2: prefix and suffix match mode**
394 * **xx xx xx xx xx: match string. Max 5 bytes for prefix and 5 bytes for suffix**
395
396
397 )))
398
399 Examples:
400
401 1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
402
403 If we set AT+SEARCH1=1,1E 56 34.      (max 5 bytes for prefix)
404
405 The valid data will be all bytes after 1E 56 34 , so it is 2e 30 58 5f 36 41 30 31 00 49
406
407 [[image:1652954654347-831.png]]
408
409
410 1. For a return string from AT+COMMAND1:  16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
411
412 If we set AT+SEARCH1=2, 1E 56 34+31 00 49
413
414 Device will search the bytes between 1E 56 34 and 31 00 49. So it is 2e 30 58 5f 36 41 30
415
416 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image014.png]]
417
418
419 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
420
421 |(((
422 **AT+DATACUTx=a,b,c**
423
424 * **a: length for the return of AT+COMMAND**
425 * **b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.**
426 * **c: define the position for valid value.  **
427 )))
428
429 Examples:
430
431 * Grab bytes:
432
433 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image015.png]]
434
435 * Grab a section.
436
437 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image016.png]]
438
439 * Grab different sections.
440
441 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image017.png]]
442
443
444 Note:
445
446 AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0.
447
448 Example:
449
450 AT+COMMAND1=11 01 1E D0,0
451
452 AT+SEARCH1=1,1E 56 34
453
454 AT+DATACUT1=0,2,1~~5
455
456 Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
457
458 String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49
459
460 Valid payload after DataCUT command: 2e 30 58 5f 36
461
462 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]]
463
464
465
466
467 1.
468 11.
469 111. Compose the uplink payload
470
471 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
472
473
474 **Examples: AT+DATAUP=0**
475
476 Compose the uplink payload with value returns in sequence and send with **A SIGNLE UPLINK**.
477
478 Final Payload is
479
480 Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
481
482 Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
483
484 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.png]]
485
486
487
488 **Examples: AT+DATAUP=1**
489
490 Compose the uplink payload with value returns in sequence and send with **Multiply UPLINKs**.
491
492 Final Payload is
493
494 Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA
495
496 1. Battery Info (2 bytes): Battery voltage
497 1. PAYVER (1 byte): Defined by AT+PAYVER
498 1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
499 1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
500 1. DATA: Valid value: max 6 bytes(US915 version here, [[Notice*!>>path:#max_byte]]) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes
501
502 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image020.png]]
503
504
505 So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA
506
507 DATA1=RETURN1 Valid Value = 20 20 0a 33 90 41
508
509 DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= 02 aa 05 81 0a 20
510
511 DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 = 20 20 20 2d 30
512
513
514
515 Below are the uplink payloads:
516
517 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]]
518
519
520 Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:
521
522 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
523
524 * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
525
526 * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
527
528 ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
529
530
531
532 1.
533 11.
534 111. Uplink on demand
535
536 Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command.
537
538 Downlink control command:
539
540 [[0x08 command>>path:#downlink_08]]: Poll an uplink with current command set in RS485-BL.
541
542 [[0xA8 command>>path:#downlink_A8]]: Send a command to RS485-BL and uplink the output from sensors.
543
544
545
546 1.
547 11.
548 111. Uplink on Interrupt
549
550 Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
551
552 AT+INTMOD=0  Disable Interrupt
553
554 AT+INTMOD=1  Interrupt trigger by rising or falling edge.
555
556 AT+INTMOD=2  Interrupt trigger by falling edge. ( Default Value)
557
558 AT+INTMOD=3  Interrupt trigger by rising edge.
559
560
561 1.
562 11. Uplink Payload
563
564 |**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands**
565 |Value|(((
566 Battery(mV)
567
568 &
569
570 Interrupt _Flag
571 )))|(((
572 PAYLOAD_VER
573
574
575 )))|If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
576
577 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
578
579
580 function Decoder(bytes, port) {
581
582 ~/~/Payload Formats of RS485-BL Deceive
583
584 return {
585
586 ~/~/Battery,units:V
587
588 BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,
589
590 ~/~/GPIO_EXTI 
591
592 EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",
593
594 ~/~/payload of version
595
596 Pay_ver:bytes[2],
597
598 };
599
600 }
601
602
603
604
605
606
607
608 TTN V3 uplink screen shot.
609
610 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
611
612 1.
613 11. Configure RS485-BL via AT or Downlink
614
615 User can configure RS485-BL via [[AT Commands >>path:#_​Using_the_AT]]or LoRaWAN Downlink Commands
616
617 There are two kinds of Commands:
618
619 * **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
620
621 * **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
622
623 1.
624 11.
625 111. Common Commands:
626
627 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
628
629
630 1.
631 11.
632 111. Sensor related commands:
633
634 ==== Choose Device Type (RS485 or TTL) ====
635
636 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
637
638 * AT Command
639
640 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
641
642 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
643
644
645 * Downlink Payload
646
647 **0A aa**     à same as AT+MOD=aa
648
649
650
651 ==== [[RS485 Debug Command>>path:#downlink_A8]] (AT+CFGDEV) ====
652
653 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling.
654
655 * AT Command
656
657 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
658
659 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
660
661
662
663 * Downlink Payload
664
665 Format: A8 MM NN XX XX XX XX YY
666
667 Where:
668
669 * MM: 1: add CRC-16/MODBUS ; 0: no CRC
670 * NN: The length of RS485 command
671 * XX XX XX XX: RS485 command total NN bytes
672 * YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
673
674 **Example 1:**
675
676 To connect a Modbus Alarm with below commands.
677
678 * The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
679
680 * The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
681
682 So if user want to use downlink command to control to RS485 Alarm, he can use:
683
684 **A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm
685
686 **A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm
687
688 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
689
690
691 **Example 2:**
692
693 Check TTL Sensor return:
694
695 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
696
697
698
699
700 ==== Set Payload version ====
701
702 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
703
704 * AT Command:
705
706 AT+PAYVER: Set PAYVER field = 1
707
708
709 * Downlink Payload:
710
711 0xAE 01   à Set PAYVER field =  0x01
712
713 0xAE 0F   à Set PAYVER field =  0x0F
714
715
716 ==== Set RS485 Sampling Commands ====
717
718 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
719
720 These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]].
721
722
723 * AT Command:
724
725 AT+COMMANDx: Configure RS485 read command to sensor.
726
727 AT+DATACUTx: Configure how to handle return from RS485 devices.
728
729 AT+SEARCHx: Configure search command
730
731
732 * Downlink Payload:
733
734 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
735
736 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
737
738 Format: AF MM NN LL XX XX XX XX YY
739
740 Where:
741
742 * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
743 * NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
744 * LL: The length of AT+COMMAND or AT+DATACUT command
745 * XX XX XX XX: AT+COMMAND or AT+DATACUT command
746 * YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
747
748 Example:
749
750 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
751
752 **AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10**
753
754 **AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10**
755
756
757 0xAB downlink command can be used for set AT+SEARCHx
758
759 Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
760
761 * AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
762 * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
763
764 **AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
765
766
767 ==== Fast command to handle MODBUS device ====
768
769 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
770
771 This command is valid since v1.3 firmware version
772
773
774 AT+MBFUN has only two value:
775
776 * AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return
777
778 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
779
780 * AT+MBFUN=0: Disable Modbus fast reading.
781
782 Example:
783
784 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
785 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
786 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
787
788 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
789
790
791 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
792
793
794 * Downlink Commands:
795
796 A9 aa -à Same as AT+MBFUN=aa
797
798
799 ==== RS485 command timeout ====
800
801 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
802
803 Default value: 0, range:  0 ~~ 5 seconds
804
805
806 * AT Command:
807
808 AT+CMDDLaa=hex(bb cc)
809
810 Example:
811
812 **AT+CMDDL1=1000** to send the open time to 1000ms
813
814
815 * Downlink Payload:
816
817 0x AA aa bb cc
818
819 Same as: AT+CMDDLaa=hex(bb cc)
820
821 Example:
822
823 0xAA 01 03 E8  à Same as **AT+CMDDL1=1000 ms**
824
825
826 ==== [[Uplink>>path:#downlink_A8]] payload mode ====
827
828 Define to use one uplink or multiple uplinks for the sampling.
829
830 The use of this command please see: [[Compose Uplink payload>>path:#DataUP]]
831
832 * AT Command:
833
834 AT+DATAUP=0
835
836 AT+DATAUP=1
837
838
839 * Downlink Payload:
840
841 0xAD 00   à Same as AT+DATAUP=0
842
843 0xAD 01   à Same as AT+DATAUP=1
844
845
846 ==== Manually trigger an Uplink ====
847
848 Ask device to send an uplink immediately.
849
850 * Downlink Payload:
851
852 0x08 FF, RS485-BL will immediately send an uplink.
853
854
855 ==== Clear RS485 Command ====
856
857 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
858
859
860 * AT Command:
861
862 **AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
863
864 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
865
866 Example screen shot after clear all RS485 commands. 
867
868
869
870 The uplink screen shot is:
871
872 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
873
874
875 * Downlink Payload:
876
877 0x09 aa bb same as AT+CMDEAR=aa,bb
878
879
880 ==== Set Serial Communication Parameters ====
881
882 Set the Rs485 serial communication parameters:
883
884 * AT Command:
885
886 Set Baud Rate:
887
888 AT+BAUDR=9600    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
889
890
891 Set UART parity
892
893 AT+PARITY=0    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
894
895
896 Set STOPBIT
897
898 AT+STOPBIT=0    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
899
900
901 * Downlink Payload:
902
903 A7 01 aa bb: Same  AT+BAUDR=hex(aa bb)*100
904
905 Example:
906
907 * A7 01 00 60   same as AT+BAUDR=9600
908 * A7 01 04 80  same as AT+BAUDR=115200
909
910 A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
911
912 A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
913
914
915 ==== Control output power duration ====
916
917 User can set the output power duration before each sampling.
918
919 * AT Command:
920
921 Example:
922
923 AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling.
924
925 AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling.
926
927
928 * LoRaWAN Downlink Command:
929
930 07 01 aa bb  Same as AT+5VT=(aa bb)
931
932 07 02 aa bb  Same as AT+3V3T=(aa bb)
933
934
935
936
937 1.
938 11. Buttons
939
940 |**Button**|**Feature**
941 |**RST**|Reboot RS485-BL
942
943 1.
944 11. +3V3 Output
945
946 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
947
948 The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 
949
950
951 The +3V3 output time can be controlled by AT Command.
952
953 **AT+3V3T=1000**
954
955 Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
956
957
958 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
959
960
961 1.
962 11. +5V Output
963
964 RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
965
966 The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 
967
968
969 The 5V output time can be controlled by AT Command.
970
971 **AT+5VT=1000**
972
973 Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors.
974
975
976 By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor.
977
978
979
980
981 1.
982 11. LEDs
983
984 |**LEDs**|**Feature**
985 |**LED1**|Blink when device transmit a packet.
986
987 1.
988 11. Switch Jumper
989
990 |**Switch Jumper**|**Feature**
991 |**SW1**|(((
992 ISP position: Upgrade firmware via UART
993
994 Flash position: Configure device, check running status.
995 )))
996 |**SW2**|(((
997 5V position: set to compatible with 5v I/O.
998
999 3.3v position: set to compatible with 3.3v I/O.,
1000 )))
1001
1002 +3.3V: is always ON
1003
1004 +5V: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
1005
1006 1. Case Study
1007
1008 User can check this URL for some case studies.
1009
1010 [[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]
1011
1012
1013
1014
1015 1. Use AT Command
1016 11. Access AT Command
1017
1018 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1019
1020 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1021
1022
1023 In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1024
1025 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1026
1027
1028
1029 More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1030
1031
1032
1033 1.
1034 11. Common AT Command Sequence
1035 111. Multi-channel ABP mode (Use with SX1301/LG308)
1036
1037 If device has not joined network yet:
1038
1039 AT+FDR
1040
1041 AT+NJM=0
1042
1043 ATZ
1044
1045
1046 If device already joined network:
1047
1048 AT+NJM=0
1049
1050 ATZ
1051
1052 1.
1053 11.
1054 111. Single-channel ABP mode (Use with LG01/LG02)
1055
1056 AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1057
1058 AT+NJM=0 Set to ABP mode
1059
1060 AT+ADR=0 Set the Adaptive Data Rate Off
1061
1062 AT+DR=5  Set Data Rate
1063
1064 AT+TDC=60000  Set transmit interval to 60 seconds
1065
1066 AT+CHS=868400000 Set transmit frequency to 868.4Mhz
1067
1068 AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
1069
1070 AT+RX2DR=5  Set RX2DR to match the downlink DR from server. see below
1071
1072 AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1073
1074 ATZ          Reset MCU
1075
1076 **Note:**
1077
1078 1. Make sure the device is set to ABP mode in the IoT Server.
1079 1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1080 1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1081 1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1082
1083 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
1084
1085
1086 1. FAQ
1087 11. How to upgrade the image?
1088
1089 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to:
1090
1091 * Support new features
1092 * For bug fix
1093 * Change LoRaWAN bands.
1094
1095 Below shows the hardware connection for how to upload an image to RS485-BL:
1096
1097 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]
1098
1099 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1100
1101 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1102
1103 **Step3: **Open flashloader; choose the correct COM port to update.
1104
1105
1106 |(((
1107 HOLD PRO then press the RST button, SYS will be ON, then click next
1108 )))
1109
1110 |(((
1111 Board detected
1112 )))
1113
1114 |(((
1115
1116 )))
1117
1118 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]]
1119
1120
1121
1122 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]]
1123
1124
1125 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1126
1127
1128 1.
1129 11. How to change the LoRa Frequency Bands/Region?
1130
1131 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
1132
1133
1134
1135 1.
1136 11. How many RS485-Slave can RS485-BL connects?
1137
1138 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
1139
1140
1141
1142
1143 1. Trouble Shooting     
1144 11. Downlink doesn’t work, how to solve it?
1145
1146 Please see this link for debug:
1147
1148 [[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 
1149
1150
1151
1152 1.
1153 11. Why I can’t join TTN V3 in US915 /AU915 bands?
1154
1155 It might about the channels mapping. Please see for detail.
1156
1157 [[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]]
1158
1159
1160
1161 1. Order Info
1162
1163 **Part Number: RS485-BL-XXX**
1164
1165 **XXX:**
1166
1167 * **EU433**: frequency bands EU433
1168 * **EU868**: frequency bands EU868
1169 * **KR920**: frequency bands KR920
1170 * **CN470**: frequency bands CN470
1171 * **AS923**: frequency bands AS923
1172 * **AU915**: frequency bands AU915
1173 * **US915**: frequency bands US915
1174 * **IN865**: frequency bands IN865
1175 * **RU864**: frequency bands RU864
1176 * **KZ865: **frequency bands KZ865
1177
1178 1. Packing Info
1179
1180 **Package Includes**:
1181
1182 * RS485-BL x 1
1183 * Stick Antenna for LoRa RF part x 1
1184 * Program cable x 1
1185
1186 **Dimension and weight**:
1187
1188 * Device Size: 13.5 x 7 x 3 cm
1189 * Device Weight: 105g
1190 * Package Size / pcs : 14.5 x 8 x 5 cm
1191 * Weight / pcs : 170g
1192
1193 1. Support
1194
1195 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1196 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
1197
1198 [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0