Show last authors
1 (% style="text-align:center" %)
2 [[image:1653266934636-343.png||height="385" width="385"]]
3
4
5
6 **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7
8
9 **Table of Contents:**
10
11
12
13
14
15 = 1.Introduction =
16
17 == 1.1 What is RS485-BL RS485 to LoRaWAN Converter ==
18
19 (((
20
21 )))
22
23 (((
24 The Dragino RS485-BL is a **RS485 / UART to LoRaWAN Converter** for Internet of Things solutions. User can connect RS485 or UART sensor to RS485-BL converter, and configure RS485-BL to periodically read sensor data and upload via LoRaWAN network to IoT server.
25 )))
26
27 (((
28 RS485-BL can interface to RS485 sensor, 3.3v/5v UART sensor or interrupt sensor. RS485-BL provides **a 3.3v output** and** a 5v output** to power external sensors. Both output voltages are controllable to minimize the total system power consumption.
29 )))
30
31 (((
32 RS485-BL is IP67 **waterproof** and powered by **8500mAh Li-SOCI2 battery**, it is designed for long term use for several years.
33 )))
34
35 (((
36 RS485-BL runs standard **LoRaWAN 1.0.3 in Class A**. It can reach long transfer range and easy to integrate with LoRaWAN compatible gateway and IoT server.
37 )))
38
39 (((
40 For data uplink, RS485-BL sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-BL will process these returns data according to user-define rules to get the final payload and upload to LoRaWAN server.
41 )))
42
43 (((
44 For data downlink, RS485-BL runs in LoRaWAN Class A. When there is downlink commands from LoRaWAN server, RS485-BL will forward the commands from LoRaWAN server to RS485 devices.
45 )))
46
47 (((
48 Each RS485-BL pre-load with a set of unique keys for LoRaWAN registration, register these keys to LoRaWAN server and it will auto connect after power on.
49 )))
50
51 [[image:1652953304999-717.png||height="424" width="733"]]
52
53 == 1.2 Specifications ==
54
55 **Hardware System:**
56
57 * STM32L072CZT6 MCU
58 * SX1276/78 Wireless Chip 
59 * Power Consumption (exclude RS485 device):
60 ** Idle: 6uA@3.3v
61
62 *
63 ** 20dB Transmit: 130mA@3.3v
64
65 **Interface for Model:**
66
67 * 1 x RS485 Interface
68 * 1 x TTL Serial , 3.3v or 5v.
69 * 1 x I2C Interface, 3.3v or 5v.
70 * 1 x one wire interface
71 * 1 x Interrupt Interface
72 * 1 x Controllable 5V output, max
73
74 **LoRa Spec:**
75
76 * Frequency Range:
77 ** Band 1 (HF): 862 ~~ 1020 Mhz
78 ** Band 2 (LF): 410 ~~ 528 Mhz
79 * 168 dB maximum link budget.
80 * +20 dBm - 100 mW constant RF output vs.
81 * Programmable bit rate up to 300 kbps.
82 * High sensitivity: down to -148 dBm.
83 * Bullet-proof front end: IIP3 = -12.5 dBm.
84 * Excellent blocking immunity.
85 * Fully integrated synthesizer with a resolution of 61 Hz.
86 * LoRa modulation.
87 * Built-in bit synchronizer for clock recovery.
88 * Preamble detection.
89 * 127 dB Dynamic Range RSSI.
90 * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
91
92 == 1.3 Features ==
93
94 * LoRaWAN Class A & Class C protocol (default Class A)
95 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
96 * AT Commands to change parameters
97 * Remote configure parameters via LoRaWAN Downlink
98 * Firmware upgradable via program port
99 * Support multiply RS485 devices by flexible rules
100 * Support Modbus protocol
101 * Support Interrupt uplink
102
103 == 1.4 Applications ==
104
105 * Smart Buildings & Home Automation
106 * Logistics and Supply Chain Management
107 * Smart Metering
108 * Smart Agriculture
109 * Smart Cities
110 * Smart Factory
111
112 == 1.5 Firmware Change log ==
113
114 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
115
116 == 1.6 Hardware Change log ==
117
118 (((
119 v1.4
120 )))
121
122 (((
123 ~1. Change Power IC to TPS22916
124 )))
125
126
127 (((
128 v1.3
129 )))
130
131 (((
132 ~1. Change JP3 from KF350-8P to KF350-11P, Add one extra interface for I2C and one extra interface for one-wire
133 )))
134
135
136 (((
137 v1.2
138 )))
139
140 (((
141 Release version ​​​​​
142 )))
143
144 = 2. Pin mapping and Power ON Device =
145
146 (((
147 The RS485-BL is powered on by 8500mAh battery. To save battery life, RS485-BL is shipped with power off. User can put the jumper to power on RS485-BL.
148 )))
149
150 [[image:1652953055962-143.png||height="387" width="728"]]
151
152
153 The Left TXD and RXD are TTL interface for external sensor. TTL level is controlled by 3.3/5v Jumper.
154
155 = 3. Operation Mode =
156
157 == 3.1 How it works? ==
158
159 (((
160 The RS485-BL is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-BL. It will auto join the network via OTAA.
161 )))
162
163 == 3.2 Example to join LoRaWAN network ==
164
165 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
166
167 [[image:1652953414711-647.png||height="337" width="723"]]
168
169 (((
170 The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method.
171 )))
172
173 (((
174 The LG308 is already set to connect to [[TTN V3 network >>url:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
175 )))
176
177 (((
178 **Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-BL.
179 )))
180
181 (((
182 Each RS485-BL is shipped with a sticker with unique device EUI:
183 )))
184
185 [[image:1652953462722-299.png]]
186
187 (((
188 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
189 )))
190
191 (((
192 Add APP EUI in the application.
193 )))
194
195
196
197
198 [[image:image-20220519174512-1.png]]
199
200 [[image:image-20220519174512-2.png||height="328" width="731"]]
201
202 [[image:image-20220519174512-3.png||height="556" width="724"]]
203
204 [[image:image-20220519174512-4.png]]
205
206 You can also choose to create the device manually.
207
208 [[image:1652953542269-423.png||height="710" width="723"]]
209
210 Add APP KEY and DEV EUI
211
212 [[image:1652953553383-907.png||height="514" width="724"]]
213
214
215 (((
216 **Step 2**: Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
217 )))
218
219 [[image:1652953568895-172.png||height="232" width="724"]]
220
221 == 3.3 Configure Commands to read data ==
222
223 (((
224 There are plenty of RS485 and TTL level devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-BL supports flexible command set. User can use [[AT Commands or LoRaWAN Downlink>>path:#AT_COMMAND]] Command to configure how RS485-BL should read the sensor and how to handle the return from RS485 or TTL sensors.
225 )))
226
227 === 3.3.1 onfigure UART settings for RS485 or TTL communication ===
228
229 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
230
231 **~1. RS485-MODBUS mode:**
232
233 AT+MOD=1 ~/~/ Support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
234
235 **2. TTL mode:**
236
237 AT+MOD=2 ~/~/ Support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
238
239 RS485-BL default UART settings is **9600, no parity, stop bit 1**. If the sensor has a different settings, user can change the RS485-BL setting to match.
240
241 (% border="1" style="background-color:#ffffcc; color:green; width:795px" %)
242 |(((
243 **AT Commands**
244 )))|(% style="width:285px" %)(((
245 **Description**
246 )))|(% style="width:347px" %)(((
247 **Example**
248 )))
249 |(((
250 AT+BAUDR
251 )))|(% style="width:285px" %)(((
252 Set the baud rate (for RS485 connection). Default Value is: 9600.
253 )))|(% style="width:347px" %)(((
254 (((
255 AT+BAUDR=9600
256 )))
257
258 (((
259 Options: (1200,2400,4800,14400,19200,115200)
260 )))
261 )))
262 |(((
263 AT+PARITY
264 )))|(% style="width:285px" %)(((
265 (((
266 Set UART parity (for RS485 connection)
267 )))
268
269 (((
270 Default Value is: no parity.
271 )))
272 )))|(% style="width:347px" %)(((
273 (((
274 AT+PARITY=0
275 )))
276
277 (((
278 Option: 0: no parity, 1: odd parity, 2: even parity
279 )))
280 )))
281 |(((
282 AT+STOPBIT
283 )))|(% style="width:285px" %)(((
284 (((
285 Set serial stopbit (for RS485 connection)
286 )))
287
288 (((
289 Default Value is: 1bit.
290 )))
291 )))|(% style="width:347px" %)(((
292 (((
293 AT+STOPBIT=0 for 1bit
294 )))
295
296 (((
297 AT+STOPBIT=1 for 1.5 bit
298 )))
299
300 (((
301 AT+STOPBIT=2 for 2 bits
302 )))
303 )))
304
305 === 3.3.2 Configure sensors ===
306
307 (((
308 Some sensors might need to configure before normal operation. User can configure such sensor via PC or through RS485-BL AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**.
309 )))
310
311 (((
312 When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling.
313 )))
314
315 (% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
316 |**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
317 |AT+CFGDEV|(% style="width:418px" %)(((
318 This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
319
320 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
321
322 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
323 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
324
325 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>path:#AT_CFGDEV]].
326
327 === 3.3.3 Configure read commands for each sampling ===
328
329 (((
330 RS485-BL is a battery powered device; it will sleep most of time. And wake up on each period and read RS485 / TTL sensor data and uplink.
331 )))
332
333 (((
334 During each sampling, we need to confirm what commands we need to send to the sensors to read data. After the RS485/TTL sensors send back the value, it normally includes some bytes and we only need a few from them for a shorten payload.
335 )))
336
337 (((
338 To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload.
339 )))
340
341 (((
342 This section describes how to achieve above goals.
343 )))
344
345 (((
346 During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
347 )))
348
349 (((
350 **Command from RS485-BL to Sensor:**
351 )))
352
353 (((
354 RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar.
355 )))
356
357 (((
358 **Handle return from sensors to RS485-BL**:
359 )))
360
361 (((
362 After RS485-BL send out a string to sensor, RS485-BL will wait for the return from RS485 or TTL sensor. And user can specify how to handle the return, by **AT+DATACUT or AT+SEARCH commands**
363 )))
364
365 * (((
366 **AT+DATACUT**
367 )))
368
369 (((
370 When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command.
371 )))
372
373 * (((
374 **AT+SEARCH**
375 )))
376
377 (((
378 When the return value from sensor is dynamic length and we are not sure which bytes the valid data is, instead, we know what value the valid value following. We can use AT+SEARCH to search the valid value in the return string.
379 )))
380
381 (((
382 **Define wait timeout:**
383 )))
384
385 (((
386 Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example, AT+CMDDL1=1000 to send the open time to 1000ms
387 )))
388
389 (((
390 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
391 )))
392
393 **Examples:**
394
395 Below are examples for the how above AT Commands works.
396
397 **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
398
399 (% border="1" class="table-bordered" %)
400 |(((
401 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
402
403 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
404
405 **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command**
406 )))
407
408 For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually.
409
410 In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
411
412 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
413
414 (% border="1" class="table-bordered" %)
415 |(((
416 **AT+SEARCHx=aa,xx xx xx xx xx**
417
418 * **aa: 1: prefix match mode; 2: prefix and suffix match mode**
419 * **xx xx xx xx xx: match string. Max 5 bytes for prefix and 5 bytes for suffix**
420
421
422 )))
423
424 Examples:
425
426 1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
427
428 If we set AT+SEARCH1=1,1E 56 34.      (max 5 bytes for prefix)
429
430 The valid data will be all bytes after 1E 56 34 , so it is 2e 30 58 5f 36 41 30 31 00 49
431
432 [[image:1652954654347-831.png]]
433
434
435 1. For a return string from AT+COMMAND1:  16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
436
437 If we set AT+SEARCH1=2, 1E 56 34+31 00 49
438
439 Device will search the bytes between 1E 56 34 and 31 00 49. So it is 2e 30 58 5f 36 41 30
440
441 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image014.png]]
442
443
444 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
445
446 |(((
447 **AT+DATACUTx=a,b,c**
448
449 * **a: length for the return of AT+COMMAND**
450 * **b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.**
451 * **c: define the position for valid value.  **
452 )))
453
454 Examples:
455
456 * Grab bytes:
457
458 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image015.png]]
459
460 * Grab a section.
461
462 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image016.png]]
463
464 * Grab different sections.
465
466 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image017.png]]
467
468
469 Note:
470
471 AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0.
472
473 Example:
474
475 AT+COMMAND1=11 01 1E D0,0
476
477 AT+SEARCH1=1,1E 56 34
478
479 AT+DATACUT1=0,2,1~~5
480
481 Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
482
483 String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49
484
485 Valid payload after DataCUT command: 2e 30 58 5f 36
486
487 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]]
488
489
490
491
492 1.
493 11.
494 111. Compose the uplink payload
495
496 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
497
498
499 **Examples: AT+DATAUP=0**
500
501 Compose the uplink payload with value returns in sequence and send with **A SIGNLE UPLINK**.
502
503 Final Payload is
504
505 Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx
506
507 Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
508
509 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.png]]
510
511
512
513 **Examples: AT+DATAUP=1**
514
515 Compose the uplink payload with value returns in sequence and send with **Multiply UPLINKs**.
516
517 Final Payload is
518
519 Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA
520
521 1. Battery Info (2 bytes): Battery voltage
522 1. PAYVER (1 byte): Defined by AT+PAYVER
523 1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
524 1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
525 1. DATA: Valid value: max 6 bytes(US915 version here, [[Notice*!>>path:#max_byte]]) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes
526
527 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image020.png]]
528
529
530 So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA
531
532 DATA1=RETURN1 Valid Value = 20 20 0a 33 90 41
533
534 DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= 02 aa 05 81 0a 20
535
536 DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 = 20 20 20 2d 30
537
538
539
540 Below are the uplink payloads:
541
542 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]]
543
544
545 Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:
546
547 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
548
549 * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
550
551 * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
552
553 ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
554
555
556
557 1.
558 11.
559 111. Uplink on demand
560
561 Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command.
562
563 Downlink control command:
564
565 [[0x08 command>>path:#downlink_08]]: Poll an uplink with current command set in RS485-BL.
566
567 [[0xA8 command>>path:#downlink_A8]]: Send a command to RS485-BL and uplink the output from sensors.
568
569
570
571 1.
572 11.
573 111. Uplink on Interrupt
574
575 Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
576
577 AT+INTMOD=0  Disable Interrupt
578
579 AT+INTMOD=1  Interrupt trigger by rising or falling edge.
580
581 AT+INTMOD=2  Interrupt trigger by falling edge. ( Default Value)
582
583 AT+INTMOD=3  Interrupt trigger by rising edge.
584
585
586 1.
587 11. Uplink Payload
588
589 |**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands**
590 |Value|(((
591 Battery(mV)
592
593 &
594
595 Interrupt _Flag
596 )))|(((
597 PAYLOAD_VER
598
599
600 )))|If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
601
602 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
603
604
605 function Decoder(bytes, port) {
606
607 ~/~/Payload Formats of RS485-BL Deceive
608
609 return {
610
611 ~/~/Battery,units:V
612
613 BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,
614
615 ~/~/GPIO_EXTI 
616
617 EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",
618
619 ~/~/payload of version
620
621 Pay_ver:bytes[2],
622
623 };
624
625 }
626
627
628
629
630
631
632
633 TTN V3 uplink screen shot.
634
635 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
636
637 1.
638 11. Configure RS485-BL via AT or Downlink
639
640 User can configure RS485-BL via [[AT Commands >>path:#_​Using_the_AT]]or LoRaWAN Downlink Commands
641
642 There are two kinds of Commands:
643
644 * **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
645
646 * **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
647
648 1.
649 11.
650 111. Common Commands:
651
652 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
653
654
655 1.
656 11.
657 111. Sensor related commands:
658
659 ==== Choose Device Type (RS485 or TTL) ====
660
661 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
662
663 * AT Command
664
665 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
666
667 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
668
669
670 * Downlink Payload
671
672 **0A aa**     à same as AT+MOD=aa
673
674
675
676 ==== [[RS485 Debug Command>>path:#downlink_A8]] (AT+CFGDEV) ====
677
678 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling.
679
680 * AT Command
681
682 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
683
684 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
685
686
687
688 * Downlink Payload
689
690 Format: A8 MM NN XX XX XX XX YY
691
692 Where:
693
694 * MM: 1: add CRC-16/MODBUS ; 0: no CRC
695 * NN: The length of RS485 command
696 * XX XX XX XX: RS485 command total NN bytes
697 * YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
698
699 **Example 1:**
700
701 To connect a Modbus Alarm with below commands.
702
703 * The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
704
705 * The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
706
707 So if user want to use downlink command to control to RS485 Alarm, he can use:
708
709 **A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm
710
711 **A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm
712
713 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
714
715
716 **Example 2:**
717
718 Check TTL Sensor return:
719
720 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
721
722
723
724
725 ==== Set Payload version ====
726
727 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
728
729 * AT Command:
730
731 AT+PAYVER: Set PAYVER field = 1
732
733
734 * Downlink Payload:
735
736 0xAE 01   à Set PAYVER field =  0x01
737
738 0xAE 0F   à Set PAYVER field =  0x0F
739
740
741 ==== Set RS485 Sampling Commands ====
742
743 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
744
745 These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]].
746
747
748 * AT Command:
749
750 AT+COMMANDx: Configure RS485 read command to sensor.
751
752 AT+DATACUTx: Configure how to handle return from RS485 devices.
753
754 AT+SEARCHx: Configure search command
755
756
757 * Downlink Payload:
758
759 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
760
761 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
762
763 Format: AF MM NN LL XX XX XX XX YY
764
765 Where:
766
767 * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
768 * NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
769 * LL: The length of AT+COMMAND or AT+DATACUT command
770 * XX XX XX XX: AT+COMMAND or AT+DATACUT command
771 * YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
772
773 Example:
774
775 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
776
777 **AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10**
778
779 **AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10**
780
781
782 0xAB downlink command can be used for set AT+SEARCHx
783
784 Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
785
786 * AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
787 * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
788
789 **AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
790
791
792 ==== Fast command to handle MODBUS device ====
793
794 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
795
796 This command is valid since v1.3 firmware version
797
798
799 AT+MBFUN has only two value:
800
801 * AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return
802
803 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
804
805 * AT+MBFUN=0: Disable Modbus fast reading.
806
807 Example:
808
809 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
810 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
811 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
812
813 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
814
815
816 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
817
818
819 * Downlink Commands:
820
821 A9 aa -à Same as AT+MBFUN=aa
822
823
824 ==== RS485 command timeout ====
825
826 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
827
828 Default value: 0, range:  0 ~~ 5 seconds
829
830
831 * AT Command:
832
833 AT+CMDDLaa=hex(bb cc)
834
835 Example:
836
837 **AT+CMDDL1=1000** to send the open time to 1000ms
838
839
840 * Downlink Payload:
841
842 0x AA aa bb cc
843
844 Same as: AT+CMDDLaa=hex(bb cc)
845
846 Example:
847
848 0xAA 01 03 E8  à Same as **AT+CMDDL1=1000 ms**
849
850
851 ==== [[Uplink>>path:#downlink_A8]] payload mode ====
852
853 Define to use one uplink or multiple uplinks for the sampling.
854
855 The use of this command please see: [[Compose Uplink payload>>path:#DataUP]]
856
857 * AT Command:
858
859 AT+DATAUP=0
860
861 AT+DATAUP=1
862
863
864 * Downlink Payload:
865
866 0xAD 00   à Same as AT+DATAUP=0
867
868 0xAD 01   à Same as AT+DATAUP=1
869
870
871 ==== Manually trigger an Uplink ====
872
873 Ask device to send an uplink immediately.
874
875 * Downlink Payload:
876
877 0x08 FF, RS485-BL will immediately send an uplink.
878
879
880 ==== Clear RS485 Command ====
881
882 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
883
884
885 * AT Command:
886
887 **AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
888
889 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
890
891 Example screen shot after clear all RS485 commands. 
892
893
894
895 The uplink screen shot is:
896
897 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
898
899
900 * Downlink Payload:
901
902 0x09 aa bb same as AT+CMDEAR=aa,bb
903
904
905 ==== Set Serial Communication Parameters ====
906
907 Set the Rs485 serial communication parameters:
908
909 * AT Command:
910
911 Set Baud Rate:
912
913 AT+BAUDR=9600    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
914
915
916 Set UART parity
917
918 AT+PARITY=0    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
919
920
921 Set STOPBIT
922
923 AT+STOPBIT=0    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
924
925
926 * Downlink Payload:
927
928 A7 01 aa bb: Same  AT+BAUDR=hex(aa bb)*100
929
930 Example:
931
932 * A7 01 00 60   same as AT+BAUDR=9600
933 * A7 01 04 80  same as AT+BAUDR=115200
934
935 A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
936
937 A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
938
939
940 ==== Control output power duration ====
941
942 User can set the output power duration before each sampling.
943
944 * AT Command:
945
946 Example:
947
948 AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling.
949
950 AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling.
951
952
953 * LoRaWAN Downlink Command:
954
955 07 01 aa bb  Same as AT+5VT=(aa bb)
956
957 07 02 aa bb  Same as AT+3V3T=(aa bb)
958
959
960
961
962 1.
963 11. Buttons
964
965 |**Button**|**Feature**
966 |**RST**|Reboot RS485-BL
967
968 1.
969 11. +3V3 Output
970
971 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
972
973 The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 
974
975
976 The +3V3 output time can be controlled by AT Command.
977
978 **AT+3V3T=1000**
979
980 Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
981
982
983 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
984
985
986 1.
987 11. +5V Output
988
989 RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
990
991 The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 
992
993
994 The 5V output time can be controlled by AT Command.
995
996 **AT+5VT=1000**
997
998 Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors.
999
1000
1001 By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor.
1002
1003
1004
1005
1006 1.
1007 11. LEDs
1008
1009 |**LEDs**|**Feature**
1010 |**LED1**|Blink when device transmit a packet.
1011
1012 1.
1013 11. Switch Jumper
1014
1015 |**Switch Jumper**|**Feature**
1016 |**SW1**|(((
1017 ISP position: Upgrade firmware via UART
1018
1019 Flash position: Configure device, check running status.
1020 )))
1021 |**SW2**|(((
1022 5V position: set to compatible with 5v I/O.
1023
1024 3.3v position: set to compatible with 3.3v I/O.,
1025 )))
1026
1027 +3.3V: is always ON
1028
1029 +5V: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
1030
1031 1. Case Study
1032
1033 User can check this URL for some case studies.
1034
1035 [[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]
1036
1037
1038
1039
1040 1. Use AT Command
1041 11. Access AT Command
1042
1043 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1044
1045 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1046
1047
1048 In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1049
1050 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1051
1052
1053
1054 More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1055
1056
1057
1058 1.
1059 11. Common AT Command Sequence
1060 111. Multi-channel ABP mode (Use with SX1301/LG308)
1061
1062 If device has not joined network yet:
1063
1064 AT+FDR
1065
1066 AT+NJM=0
1067
1068 ATZ
1069
1070
1071 If device already joined network:
1072
1073 AT+NJM=0
1074
1075 ATZ
1076
1077 1.
1078 11.
1079 111. Single-channel ABP mode (Use with LG01/LG02)
1080
1081 AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1082
1083 AT+NJM=0 Set to ABP mode
1084
1085 AT+ADR=0 Set the Adaptive Data Rate Off
1086
1087 AT+DR=5  Set Data Rate
1088
1089 AT+TDC=60000  Set transmit interval to 60 seconds
1090
1091 AT+CHS=868400000 Set transmit frequency to 868.4Mhz
1092
1093 AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
1094
1095 AT+RX2DR=5  Set RX2DR to match the downlink DR from server. see below
1096
1097 AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1098
1099 ATZ          Reset MCU
1100
1101 **Note:**
1102
1103 1. Make sure the device is set to ABP mode in the IoT Server.
1104 1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1105 1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1106 1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1107
1108 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
1109
1110
1111 1. FAQ
1112 11. How to upgrade the image?
1113
1114 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to:
1115
1116 * Support new features
1117 * For bug fix
1118 * Change LoRaWAN bands.
1119
1120 Below shows the hardware connection for how to upload an image to RS485-BL:
1121
1122 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]
1123
1124 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1125
1126 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1127
1128 **Step3: **Open flashloader; choose the correct COM port to update.
1129
1130
1131 |(((
1132 HOLD PRO then press the RST button, SYS will be ON, then click next
1133 )))
1134
1135 |(((
1136 Board detected
1137 )))
1138
1139 |(((
1140
1141 )))
1142
1143 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]]
1144
1145
1146
1147 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]]
1148
1149
1150 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1151
1152
1153 1.
1154 11. How to change the LoRa Frequency Bands/Region?
1155
1156 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
1157
1158
1159
1160 1.
1161 11. How many RS485-Slave can RS485-BL connects?
1162
1163 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
1164
1165
1166
1167
1168 1. Trouble Shooting     
1169 11. Downlink doesn’t work, how to solve it?
1170
1171 Please see this link for debug:
1172
1173 [[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 
1174
1175
1176
1177 1.
1178 11. Why I can’t join TTN V3 in US915 /AU915 bands?
1179
1180 It might about the channels mapping. Please see for detail.
1181
1182 [[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]]
1183
1184
1185
1186 1. Order Info
1187
1188 **Part Number: RS485-BL-XXX**
1189
1190 **XXX:**
1191
1192 * **EU433**: frequency bands EU433
1193 * **EU868**: frequency bands EU868
1194 * **KR920**: frequency bands KR920
1195 * **CN470**: frequency bands CN470
1196 * **AS923**: frequency bands AS923
1197 * **AU915**: frequency bands AU915
1198 * **US915**: frequency bands US915
1199 * **IN865**: frequency bands IN865
1200 * **RU864**: frequency bands RU864
1201 * **KZ865: **frequency bands KZ865
1202
1203 1. Packing Info
1204
1205 **Package Includes**:
1206
1207 * RS485-BL x 1
1208 * Stick Antenna for LoRa RF part x 1
1209 * Program cable x 1
1210
1211 **Dimension and weight**:
1212
1213 * Device Size: 13.5 x 7 x 3 cm
1214 * Device Weight: 105g
1215 * Package Size / pcs : 14.5 x 8 x 5 cm
1216 * Weight / pcs : 170g
1217
1218 1. Support
1219
1220 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1221 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
1222
1223 [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0