Show last authors
1 (% aria-label="1653266934636-343.png image widget" contenteditable="false" role="region" tabindex="-1" %)
2 (((
3 (% data-widget="image" style="text-align:center" %)
4 [[image:1653266934636-343.png||height="385" width="385"]](% title="Click and drag to resize" %)​
5
6 (% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||height="15" role="presentation" title="Click and drag to move" width="15"]]
7 )))
8
9
10
11
12
13
14
15 **Table of Contents:**
16
17 {{toc/}}
18
19
20 (% aria-label="macro:toc widget" contenteditable="false" role="region" tabindex="-1" %)
21 (((
22 (% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||height="15" role="presentation" title="Click and drag to move" width="15"]]
23 )))
24
25
26
27
28
29
30
31 = 1. Introduction =
32
33 == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
34
35
36 (((
37 The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
38 )))
39
40 (((
41 RS485-LN allows user to (% style="color:blue" %)**monitor / control RS485 devices**(%%) and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
42 )))
43
44 (((
45 (% style="color:blue" %)**For data uplink**(%%), RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server.
46 )))
47
48 (((
49 (% style="color:blue" %)**For data downlink**(%%), RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices.
50 )))
51
52 (((
53 (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]]
54 )))
55
56
57 (% aria-label="1653267211009-519.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653267211009-519.png||data-widget="image" height="419" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
58
59
60 == 1.2 Specifications ==
61
62
63 (% style="color:#037691" %)**Hardware System:**
64
65 * STM32L072xxxx MCU
66 * SX1276/78 Wireless Chip 
67 * Power Consumption (exclude RS485 device):
68 ** Idle: 32mA@12v
69 ** 20dB Transmit: 65mA@12v
70
71 (% style="color:#037691" %)**Interface for Model:**
72
73 * RS485
74 * Power Input 7~~ 24V DC. 
75
76 (% style="color:#037691" %)**LoRa Spec:**
77
78 * Frequency Range:
79 ** Band 1 (HF): 862 ~~ 1020 Mhz
80 ** Band 2 (LF): 410 ~~ 528 Mhz
81 * 168 dB maximum link budget.
82 * +20 dBm - 100 mW constant RF output vs.
83 * +14 dBm high efficiency PA.
84 * Programmable bit rate up to 300 kbps.
85 * High sensitivity: down to -148 dBm.
86 * Bullet-proof front end: IIP3 = -12.5 dBm.
87 * Excellent blocking immunity.
88 * Low RX current of 10.3 mA, 200 nA register retention.
89 * Fully integrated synthesizer with a resolution of 61 Hz.
90 * FSK, GFSK, MSK, GMSK, LoRaTM and OOK modulation.
91 * Built-in bit synchronizer for clock recovery.
92 * Preamble detection.
93 * 127 dB Dynamic Range RSSI.
94 * Automatic RF Sense and CAD with ultra-fast AFC.
95 * Packet engine up to 256 bytes with CRC
96
97 == 1.3 Features ==
98
99
100 * LoRaWAN Class A & Class C protocol (default Class C)
101 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864/MA869
102 * AT Commands to change parameters
103 * Remote configure parameters via LoRa Downlink
104 * Firmware upgradable via program port
105 * Support multiply RS485 devices by flexible rules
106 * Support Modbus protocol
107 * Support Interrupt uplink (Since hardware version v1.2)
108
109 == 1.4 Applications ==
110
111
112 * Smart Buildings & Home Automation
113 * Logistics and Supply Chain Management
114 * Smart Metering
115 * Smart Agriculture
116 * Smart Cities
117 * Smart Factory
118
119 == 1.5 Firmware Change log ==
120
121
122 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
123
124
125 == 1.6 Hardware Change log ==
126
127
128 (((
129 (((
130 (((
131 v1.2: Add External Interrupt Pin.
132 )))
133
134 (((
135 v1.0: Release
136 )))
137
138
139 )))
140 )))
141
142 = 2. Power ON Device =
143
144
145 (((
146 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
147
148 * Power Source VIN to RS485-LN VIN+
149 * Power Source GND to RS485-LN VIN-
150
151 (((
152 Once there is power, the RS485-LN will be on.
153 )))
154
155 (% aria-label="1653268091319-405.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268091319-405.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
156
157
158 )))
159
160 = 3. Operation Mode =
161
162 == 3.1 How it works? ==
163
164
165 (((
166 (((
167 The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
168 )))
169
170
171 )))
172
173 == 3.2 Example to join LoRaWAN network ==
174
175
176 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
177
178
179 (% aria-label="1653268155545-638.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268155545-638.png||data-widget="image" height="334" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
180
181
182 (((
183 (((
184 The RS485-LN in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. The connection is as below:
185 )))
186
187 (((
188 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
189
190
191 )))
192
193 (% aria-label="1653268227651-549.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268227651-549.png||data-widget="image" height="592" width="720"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
194
195
196 (((
197 The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
198
199
200 )))
201
202 (((
203 (% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-LN.
204 )))
205
206 (((
207 Each RS485-LN is shipped with a sticker with unique device EUI:
208 )))
209 )))
210
211 (% aria-label="1652953462722-299.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953462722-299.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
212
213
214 (((
215 (((
216 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
217
218
219 )))
220
221 (((
222 **Add APP EUI in the application.**
223 )))
224 )))
225
226 (% aria-label="image-20220519174512-1.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
227
228 (% aria-label="image-20220519174512-2.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-2.png||data-widget="image" height="323" width="720"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
229
230 (% aria-label="image-20220519174512-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-3.png||data-widget="image" height="556" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
231
232 (% aria-label="image-20220519174512-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220519174512-4.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
233
234
235 (% title="Click and drag to resize" %)​
236
237 You can also choose to create the device manually.
238
239 (% aria-label="1652953542269-423.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953542269-423.png||data-widget="image" height="710" width="723"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
240
241
242
243 **Add APP KEY and DEV EUI**
244
245 (% aria-label="1652953553383-907.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953553383-907.png||data-widget="image" height="514" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
246
247
248
249 (((
250 (% style="color:blue" %)**Step 2**(%%): Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
251
252
253 )))
254
255 (% aria-label="1652953568895-172.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953568895-172.png||data-widget="image" height="232" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
256
257
258 == 3.3 Configure Commands to read data ==
259
260
261 (((
262 (((
263 (((
264 There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
265
266
267 )))
268 )))
269
270 (((
271 (((
272 (% style="color:red" %)**Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1**
273 )))
274
275
276 )))
277 )))
278
279 === 3.3.1 Configure UART settings for RS485 or TTL communication ===
280
281
282 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
283
284
285 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
286 |=(% style="width: 119px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
287 **AT Commands**
288 )))|=(% style="width: 116px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
289 **Description**
290 )))|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)(((
291 **Example**
292 )))
293 |(% style="width:119px" %)(((
294 AT+BAUDR
295 )))|(% style="width:116px" %)(((
296 Set the baud rate (for RS485 connection). Default Value is: 9600.
297 )))|(% style="width:190px" %)(((
298 (((
299 AT+BAUDR=9600
300 )))
301
302 (((
303 Options: (1200,2400,4800,14400,19200,115200)
304 )))
305 )))
306 |(% style="width:119px" %)(((
307 AT+PARITY
308 )))|(% style="width:116px" %)(((
309 Set UART parity (for RS485 connection)
310 )))|(% style="width:190px" %)(((
311 (((
312 AT+PARITY=0
313 )))
314
315 (((
316 Option: 0: no parity, 1: odd parity, 2: even parity
317 )))
318 )))
319 |(% style="width:119px" %)(((
320 AT+STOPBIT
321 )))|(% style="width:116px" %)(((
322 (((
323 Set serial stopbit (for RS485 connection)
324 )))
325
326 (((
327
328 )))
329 )))|(% style="width:190px" %)(((
330 (((
331 AT+STOPBIT=0 for 1bit
332 )))
333
334 (((
335 AT+STOPBIT=1 for 1.5 bit
336 )))
337
338 (((
339 AT+STOPBIT=2 for 2 bits
340 )))
341 )))
342
343 === 3.3.2 Configure sensors ===
344
345
346 (((
347 (((
348 Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling.
349
350
351 )))
352 )))
353
354 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
355 |=(% style="width: 122px; background-color:#D9E2F3;color:#0070C0" %)**AT Commands**|=(% style="width: 198px; background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Example**
356 |(% style="width:122px" %)AT+CFGDEV|(% style="width:196px" %)(((
357 (((
358 This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
359 )))
360
361 (((
362 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
363 )))
364
365 (((
366 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
367 )))
368 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
369
370 === 3.3.3 Configure read commands for each sampling ===
371
372
373 (((
374 During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload.
375
376 To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload.
377
378 This section describes how to achieve above goals.
379
380 During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
381
382
383 (% style="color:#037691" %)**Each RS485 commands include two parts:**
384
385
386 ~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar.
387
388 2. How to get wanted value the from RS485 sensors returns from by 1). There are total 15 AT Commands to handle the return, commands are **AT+DATACUT1**,**AT+DATACUT2**,…, **AT+DATACUTF** corresponding to the commands from 1). All commands are of same grammar.
389
390 3. Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example **AT+CMDDL1=1000** to send the open time to 1000ms
391
392
393 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
394
395 Below are examples for the how above AT Commands works.
396
397
398 (% style="color:#037691" %)**AT+COMMANDx **(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
399
400 (% border="1" style="background-color:#f2f2f2; width:499px" %)
401 |(% style="width:496px" %)(((
402 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
403
404 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
405
406 **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command**
407 )))
408
409 For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually.
410
411 In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
412
413
414 (% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes.
415
416 (% border="1" style="background-color:#f2f2f2; width:510px" %)
417 |(% style="width:510px" %)(((
418 **AT+DATACUTx=a,b,c**
419
420 * **a: length for the return of AT+COMMAND**
421 * **b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.**
422 * **c: define the position for valid value.  **
423 )))
424
425 **Examples:**
426
427
428 * (% style="color:#037691" %)**Grab bytes**
429
430 (% aria-label="image-20220602153621-1.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
431
432
433
434 * (% style="color:#037691" %)**Grab a section**
435
436 (% aria-label="image-20220602153621-2.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-2.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
437
438
439
440 * (% style="color:#037691" %)**Grab different sections**
441
442 (% aria-label="image-20220602153621-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-3.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
443
444
445 )))
446
447 === 3.3.4 Compose the uplink payload ===
448
449
450 (((
451 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
452
453
454 )))
455
456 (((
457 (% style="color:#037691" %)**Examples: AT+DATAUP=0**
458
459
460 )))
461
462 (((
463 Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**A SIGNLE UPLINK**.
464 )))
465
466 (((
467 Final Payload is (% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx**
468 )))
469
470 (((
471 Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
472
473
474 )))
475
476 [[image:image-20220929111027-1.png||height="509" width="685"]](% title="Click and drag to resize" %)​
477
478
479 (% style="color:#037691" %)**Examples: AT+DATAUP=1**
480
481
482 Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**Multiply UPLINKs**.
483
484 Final Payload is (% style="color:#4f81bd" %)**PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
485
486
487 ~1. PAYVER: Defined by AT+PAYVER
488
489 2. PAYLOAD COUNT: Total how many uplinks of this sampling.
490
491 3. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
492
493 4. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
494
495
496 (% aria-label="image-20220602155039-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602155039-4.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
497
498
499 So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
500
501 DATA1=RETURN1 Valid Value + the first two of Valid value of RETURN10= **20 20 0a 33 90 41 02 aa**
502
503 DATA2=3^^rd^^ ~~ 10^^th^^ byte of Valid value of RETURN10= **05 81 0a 20 20 20 20 2d**
504
505 DATA3=the rest of Valid value of RETURN10= **30**
506
507
508 (% style="color:red" %)**Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:**
509
510
511 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink.
512
513 * For AU915/AS923 bands, if UplinkDwell time=0, max 11 bytes for each uplink.
514
515 * For US915 band, max 11 bytes for each uplink.
516
517 ~* For all other bands: max 51 bytes for each uplink.
518
519
520 (% style="color:red" %)** When AT+DATAUP=1, the maximum number of segments is 15, and the maximum total number of bytes is 1500;**
521
522 (% style="color:red" %)** When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value. (Since v1.4.0)**
523
524
525
526 Below are the uplink payloads:
527
528
529 (% aria-label="1654157178836-407.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157178836-407.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
530
531
532 === 3.3.5 Uplink on demand ===
533
534
535 Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command.
536
537 (% style="color:blue" %)**Downlink control command:**
538
539 (% style="color:#4472c4" %)** 0x08 command**(%%): Poll an uplink with current command set in RS485-LN.
540
541 (% style="color:#4472c4" %)** 0xA8 command**(%%): Send a command to RS485-LN and uplink the output from sensors.
542
543
544 === 3.3.6 Uplink on Interrupt ===
545
546
547 RS485-LN support external Interrupt uplink since hardware v1.2 release.
548
549
550 (% aria-label="1654157342174-798.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157342174-798.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
551
552 Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
553
554
555 == 3.4 Uplink Payload ==
556
557
558 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
559 |=(% scope="row" style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)(((
560 Size(bytes)
561 )))|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:360px" %)(((
562 **Length depends on the return from the commands**
563 )))
564 |=(% style="width: 90px;" %)(((
565 Value
566 )))|(% style="width:114px" %)(((
567 PAYLOAD_VER
568 )))|(% style="width:353px" %)(((
569 If the valid payload is too long and exceed the maximum
570
571 support payload length in server, server will show payload not
572
573 provided in the LoRaWAN server.
574 )))
575
576 (% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
577
578 (% title="Click and drag to resize" %)​
579
580 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
581
582
583 == 3.5 Configure RS485-LN via AT or Downlink ==
584
585
586 (((
587 User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
588 )))
589
590 (((
591 There are two kinds of Commands:
592 )))
593
594 * (((
595 (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
596 )))
597
598 * (((
599 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
600 )))
601
602 (((
603
604 )))
605
606
607 === 3.5.1 Common Commands ===
608
609
610 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
611
612
613 === 3.5.2 Downlink Response(Since firmware v1.4) ===
614
615
616 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
617
618
619 (% aria-label="image-20220602163333-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602163333-5.png||data-widget="image" height="263" width="1160"]]
620
621 (% title="Click and drag to resize" %)​
622
623 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
624
625
626 === 3.5.3 Sensor related commands ===
627
628
629
630 ==== (% style="color:blue" %)**RS485 Debug Command**(%%) ====
631
632
633 (((
634 This command is used to configure the RS485 devices; they won't be used during sampling. Max Length of AT+CFGDEV is **40 bytes**.
635 )))
636
637 (((
638 * (% style="color:#037691" %)**AT Command**
639
640 (((
641 (% style="color:#4472c4" %)** AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**  (%%) m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
642 )))
643 )))
644
645 (((
646
647 )))
648
649 * (((
650 (% style="color:#037691" %)**Downlink Payload**
651 )))
652
653 (((
654 Format: (% style="color:#4472c4" %)** A8 MM NN XX XX XX XX YY**
655 )))
656
657 (((
658 Where:
659 )))
660
661 * (((
662 MM: 1: add CRC-16/MODBUS ; 0: no CRC
663 )))
664 * (((
665 NN: The length of RS485 command
666 )))
667 * (((
668 XX XX XX XX: RS485 command total NN bytes
669 )))
670 * (((
671 (((
672 YY: How many bytes will be uplink from the return of this RS485 command,
673 )))
674
675 * (((
676 if YY=0, RS485-LN will execute the downlink command without uplink;
677 )))
678 * (((
679 if YY>0, RS485-LN will uplink total YY bytes from the output of this RS485 command; Fport=200
680 )))
681 * (((
682 if YY=FF, RS485-LN will uplink RS485 output with the downlink command content; Fport=200.
683 )))
684 )))
685
686 (((
687
688
689 (% style="color:blue" %)**Example 1:**  (%%) ~-~-> Configure without ask for uplink (YY=0)
690 )))
691
692 (((
693 To connect a Modbus Alarm with below commands.
694 )))
695
696 * (((
697 The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
698 )))
699
700 * (((
701 The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
702 )))
703
704 (((
705
706
707 So if user want to use downlink command to control to RS485 Alarm, he can use:
708 )))
709
710 (((
711 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
712 )))
713
714 (((
715 (% style="color:#4f81bd" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
716 )))
717
718 (((
719 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
720 )))
721
722 (((
723
724 )))
725
726 (((
727 (% style="color:blue" %)**Example 2:**  (%%) ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
728 )))
729
730 (((
731 User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY**
732 )))
733
734 (((
735
736 )))
737
738 (((
739 (((
740 RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
741 )))
742
743
744 )))
745
746 (((
747 (% aria-label="1654159460680-153.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654159460680-153.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
748 )))
749
750
751
752 ==== (% style="color:blue" %)**Set Payload version**(%%) ====
753
754
755 (((
756 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
757 )))
758
759 (((
760 * (% style="color:#037691" %)**AT Command:**
761
762 (% style="color:#4472c4" %)** AT+PAYVER:    ** (%%) Set PAYVER field = 1
763
764
765 )))
766
767 * (((
768 (% style="color:#037691" %)**Downlink Payload:**
769 )))
770
771 (((
772 (% style="color:#4472c4" %)** 0xAE 01** (%%) ~-~->  Set PAYVER field =  0x01
773 )))
774
775 (((
776 (% style="color:#4472c4" %)** 0xAE 0F**   (%%) ~-~->  Set PAYVER field =  0x0F
777 )))
778
779
780 **1 )  Add the interrupt flag at the highest bit of the Payver byte, that is, Byte7 of the first byte. (Since v1.4.0)**
781
782
783 [[image:image-20220824145428-2.png||height="168" width="1300"]]
784
785
786
787 **2 )  if the data intercepted by AT+DATACUT or AT+MBFUN is empty, it will display NULL, and the payload will be filled with n FFs.**
788
789
790 [[image:image-20220824145428-3.png||height="308" width="1200"]]
791
792
793
794 ==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ====
795
796
797 (((
798 AT+COMMANDx or AT+DATACUTx
799 )))
800
801 (((
802 These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
803 )))
804
805 (((
806
807 )))
808
809 * (((
810 (% style="color:#037691" %)**AT Command:**
811 )))
812
813 (% style="color:#4472c4" %)** AT+COMMANDx:    ** (%%) Configure RS485 read command to sensor.
814
815 (% style="color:#4472c4" %)** AT+DATACUTx:        **(%%) Configure how to handle return from RS485 devices.
816
817
818 * (((
819 (% style="color:#037691" %)**Downlink Payload:**
820 )))
821
822 (((
823 (% style="color:#4472c4" %)** 0xAF**(%%) downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
824
825
826 )))
827
828 (((
829 (% style="color:red" %)**Note : if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.**
830
831
832 )))
833
834 (((
835 Format: (% style="color:#4472c4" %)** AF MM NN LL XX XX XX XX YY**
836 )))
837
838 (((
839 Where:
840 )))
841
842 * (((
843 MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
844 )))
845 * (((
846 NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
847 )))
848 * (((
849 LL:  The length of AT+COMMAND or AT+DATACUT command
850 )))
851 * (((
852 XX XX XX XX: AT+COMMAND or AT+DATACUT command
853 )))
854 * (((
855 YY:  If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
856 )))
857
858 (((
859
860
861 **Example:**
862 )))
863
864 (((
865 (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1
866 )))
867
868 (((
869 (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10**
870 )))
871
872 (((
873 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
874 )))
875
876
877
878 ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
879
880
881 (((
882 (% style="color:#4472c4" %)** AT+MBFUN**(%%) is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
883 )))
884
885 (((
886 This command is valid since v1.3 firmware version
887 )))
888
889 (((
890 AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
891 )))
892
893 (((
894
895 )))
896
897 (((
898 **Example:**
899 )))
900
901 * (((
902 AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2  are not configure (0,0,0). So RS485-LN.
903 )))
904 * (((
905 AT+COMMAND1= 01 03 00 10 00 08,1  ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
906 )))
907 * (((
908 AT+COMMAND2= 01 02 00 40 00 10,1  ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
909
910
911 )))
912
913 (% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]]
914
915 (% title="Click and drag to resize" %)​
916
917 (% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %)​
918
919
920
921 ==== (% style="color:blue" %)**RS485 command timeout**(%%) ====
922
923
924 (((
925 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
926 )))
927
928 (((
929 Default value: 0, range:  0 ~~ 65 seconds
930 )))
931
932 (((
933 * (% style="color:#037691" %)** AT Command:**
934
935 (% style="color:#4472c4" %)** AT+CMDDLaa=hex(bb cc)*1000**
936 )))
937
938 (((
939
940
941 **Example:**
942 )))
943
944 (((
945 (% style="color:#4472c4" %)** AT+CMDDL1=1000** (%%)to send the open time to 1000ms
946 )))
947
948 (((
949
950 )))
951
952 * (((
953 (% style="color:#037691" %)** Downlink Payload:**
954 )))
955
956 (((
957 (% style="color:#4472c4" %)** 0x AA aa bb cc**(%%) Same as: AT+CMDDLaa=hex (bb cc)
958 )))
959
960 (((
961
962
963 **Example:**
964 )))
965
966 (((
967 **0xAA 01 03 E8**  ~-~-> Same as  **AT+CMDDL1=1000 ms**
968 )))
969
970
971
972 ==== (% style="color:blue" %)**Uplink payload mode**(%%) ====
973
974
975 (((
976 Define to use one uplink or multiple uplinks for the sampling.
977 )))
978
979 (((
980 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
981
982
983 )))
984
985 (((
986 * (% style="color:#037691" %)** AT Command:**
987
988 (% style="color:#4472c4" %)** AT+DATAUP=0**
989
990 (% style="color:#4472c4" %)** AT+DATAUP=1**
991
992
993 )))
994
995 (% style="color:#4472c4" %)** 0xAD 01 00 00 14** (%%) **~-~->** Same as AT+DATAUP=1,20000  ~/~/  (00 00 14 is 20 seconds)
996
997 Each uplink is sent to the server at 20-second intervals when segmented.
998
999
1000 * (((
1001 (% style="color:#037691" %)** Downlink Payload:**
1002 )))
1003
1004 (% style="color:#4472c4" %)** 0xAD 00** (%%) **~-~->** Same as AT+DATAUP=0
1005
1006 (% style="color:#4472c4" %)** 0xAD 01**  (%%) **~-~->** Same as AT+DATAUP=1  ~/~/Each uplink is sent to the server one after the other as it is segmented.
1007
1008
1009 * (((
1010 (% style="color:#037691" %)** AT Command:**
1011 )))
1012
1013 (% style="color:#4472c4" %)** AT+DATAUP=1,Timeout**
1014
1015
1016 * (((
1017 (% style="color:#037691" %)** Downlink Payload:**
1018 )))
1019
1020 (% style="color:#4472c4" %)** 0xAD 01 00 00 14** (%%) **~-~->** Same as AT+DATAUP=1,20000  ~/~/  (00 00 14 is 20 seconds)
1021
1022 Each uplink is sent to the server at 20-second intervals when segmented.
1023
1024
1025
1026 ==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ====
1027
1028
1029 (((
1030 Ask device to send an uplink immediately.
1031 )))
1032
1033 * (((
1034 (% style="color:#037691" %)** AT Command:**
1035 )))
1036
1037 (((
1038 No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
1039 )))
1040
1041 (((
1042
1043 )))
1044
1045 * (((
1046 (% style="color:#037691" %)** Downlink Payload:**
1047 )))
1048
1049 (((
1050 (% style="color:#4472c4" %)** 0x08 FF**(%%), RS485-LN will immediately send an uplink.
1051 )))
1052
1053
1054
1055 ==== (% style="color:blue" %)**Clear RS485 Command**(%%) ====
1056
1057
1058 (((
1059 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
1060
1061
1062 )))
1063
1064 * (((
1065 (% style="color:#037691" %)** AT Command:**
1066 )))
1067
1068 (((
1069 (% style="color:#4472c4" %)** AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase
1070 )))
1071
1072 (((
1073
1074
1075 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
1076 )))
1077
1078 (((
1079 Example screen shot after clear all RS485 commands. 
1080 )))
1081
1082 (((
1083
1084 )))
1085
1086 (((
1087 The uplink screen shot is:
1088 )))
1089
1090 (% aria-label="1654160691922-496.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654160691922-496.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1091
1092
1093 * (((
1094 (% style="color:#037691" %)** Downlink Payload:**
1095 )))
1096
1097 (((
1098 (% style="color:#4472c4" %)** 0x09 aa bb** (%%) same as AT+CMDEAR=aa,bb
1099 )))
1100
1101
1102
1103 ==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ====
1104
1105
1106 (((
1107 Set the Rs485 serial communication parameters:
1108 )))
1109
1110 (((
1111 (% style="color:#037691" %)**AT Command:**
1112 )))
1113
1114 (((
1115 * Set Baud Rate
1116 )))
1117
1118 (% style="color:#4472c4" %)** AT+BAUDR=9600** (%%) ~/~/  Options: (200~~115200)  When using low baud rate or receiving multiple bytes, you need to use AT+CMDDL to increase the receive timeout (the default receive timeout is 400ms), otherwise data will be lost
1119
1120
1121 (((
1122 * Set UART Parity
1123 )))
1124
1125 (% style="color:#4472c4" %)** AT+PARITY=0** (%%) ~/~/  Option: 0: no parity, 1: odd parity, 2: even parity
1126
1127
1128 (((
1129 * Set STOPBIT
1130 )))
1131
1132 (% style="color:#4472c4" %)** AT+STOPBIT=0** (%%) ~/~/  Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1133
1134
1135 (((
1136 (% style="color:#037691" %)**Downlink Payload:**
1137 )))
1138
1139 (((
1140 (% style="color:#4472c4" %)** A7 01 aa bb**:   (%%) Same  AT+BAUDR=hex(aa bb)*100
1141 )))
1142
1143 (((
1144 **Example:**
1145 )))
1146
1147 * (((
1148 A7 01 00 60  same as AT+BAUDR=9600
1149 )))
1150 * (((
1151 A7 01 04 80  same as AT+BAUDR=115200
1152 )))
1153
1154 (((
1155 * A7 02 aa:  Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1156 )))
1157
1158 (((
1159 * A7 03 aa:  Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1160 )))
1161
1162
1163
1164
1165 ==== (% style="color:blue" %)**Configure Databit (Since Version 1.4.0)**(%%) ====
1166
1167
1168 * (((
1169 (% style="color:#037691" %)** AT Command:**
1170 )))
1171
1172 (% style="color:#4472c4" %)** AT+DATABIT=7    **(%%)~/~/ Set the data bits to 7
1173
1174 (% style="color:#4472c4" %)** AT+DATABIT=8    **(%%)~/~/ Set the data bits to 8
1175
1176 * (((
1177 (% style="color:#037691" %)**Downlink Payload:**
1178 )))
1179
1180 (% style="color:#4472c4" %)** A7 04 07**(%%): Same as  AT+DATABIT=7
1181
1182 (% style="color:#4472c4" %)** A7 04 08**(%%): Same as  AT+DATABIT=8
1183
1184
1185
1186 ==== (% style="color:blue" %)**Encrypted payload(Since Version 1.4.0)**(%%) ====
1187
1188 (((
1189
1190 )))
1191
1192 * (((
1193 (% style="color:#037691" %)** AT Command:**
1194 )))
1195
1196 (% style="color:#4472c4" %)** AT+DECRYPT=1  ** (%%) ~/~/ The payload is uploaded without encryption
1197
1198 (% style="color:#4472c4" %)** AT+DECRYPT=0  ** (%%) ~/~/ Encrypt when uploading payload (default)
1199
1200
1201
1202 ==== (% style="color:blue" %)**Get sensor value(Since Version 1.4.0)**(%%) ====
1203
1204
1205 * (((
1206 (% style="color:#037691" %)** AT Command:**
1207 )))
1208
1209 (% style="color:#4472c4" %)** AT+GETSENSORVALUE=0  **(%%) ~/~/ The serial port gets the reading of the current sensor
1210
1211 (% style="color:#4472c4" %)** AT+GETSENSORVALUE=1  **(%%) ~/~/ The serial port gets the current sensor reading and uploads it.
1212
1213
1214
1215 ==== (% style="color:blue" %)**Resets the downlink packet count(Since Version 1.4.0)**(%%) ====
1216
1217
1218 * (((
1219 (% style="color:#037691" %)** AT Command:**
1220 )))
1221
1222 (% style="color:#4472c4" %)** AT+DISFCNTCHECK=0  **(%%) ~/~/  When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default)
1223
1224 (% style="color:#4472c4" %)** AT+DISFCNTCHECK=1  **(%%) ~/~/  When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count.
1225
1226
1227
1228 ==== (% style="color:blue" %)**When the limit bytes are exceeded, upload in batches(Since Version 1.4.0)**(%%) ====
1229
1230
1231 * (((
1232 (% style="color:#037691" %)** AT Command:**
1233 )))
1234
1235 (% style="color:#4472c4" %)** AT+DISMACANS=0**  (%%) ~/~/  When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default)
1236
1237 (% style="color:#4472c4" %)** AT+DISMACANS=1**   (%%) ~/~/  When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part.
1238
1239
1240 * (((
1241 (% style="color:#037691" %)** Downlink Payload:**
1242 )))
1243
1244 (% style="color:#4472c4" %)** 0x21 00 01 ** (%%) ~/~/ Set  the DISMACANS=1
1245
1246
1247
1248 ==== (% style="color:blue" %)**Copy downlink to uplink (Since Version 1.4.0)**(%%) ====
1249
1250
1251 * (((
1252 (% style="color:#037691" %)** AT Command:**
1253 )))
1254
1255 (% style="color:#4472c4" %)** AT+RPL=5**  (%%) ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100.
1256
1257 Example:**aa xx xx xx xx**         ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent.
1258
1259
1260 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]]
1261
1262 For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77.
1263
1264
1265
1266 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]]
1267
1268 For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned.
1269
1270
1271
1272 ==== (% style="color:blue" %)**Query version number and frequency band 、TDC(Since Version 1.4.0)**(%%) ====
1273
1274
1275 (((
1276 * (% style="color:#037691" %)**Downlink Payload:**
1277
1278 (% style="color:#4472c4" %)** 26 01  ** (%%) ~/~/  Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time.
1279 )))
1280
1281
1282 Example:
1283
1284
1285 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]]
1286
1287
1288
1289 ==== (% style="color:blue" %)** Monitor RS485 communication of other devices(Since Version 1.4.0)**(%%) ====
1290
1291
1292 * (((
1293 (% style="color:#037691" %)** AT Command:**
1294 )))
1295
1296 (% style="color:#4472c4" %)**AT+RXMODE=1,10**    (%%) ~/~/ When the RS485-LN receives more than 10 bytes from the RS485, it immediately sends the uplink of the received data.
1297
1298 (% style="color:#4472c4" %)**AT+RXMODE=2,500    ** (%%) ~/~/  RS485-LN uploads data as uplink from the first byte received by RS485 to the data received within 500ms after that.
1299
1300 (% style="color:#4472c4" %)**AT+RXMODE=0,0  ** (%%) ~/~/  Disable this mode (default)
1301
1302
1303 * (((
1304 (% style="color:#037691" %)**Downlink Payload:**
1305 )))
1306
1307 (% style="color:#4472c4" %)** A6 aa bb bb               ** (%%) ~/~/ same as AT+RXMODE=aa,bb
1308
1309 [[image:image-20220824144240-1.png]]
1310
1311
1312 == 3.6 Listening mode for RS485 network ==
1313
1314
1315 (((
1316 This feature support since firmware v1.4
1317 )))
1318
1319 (((
1320 RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1321
1322
1323 )))
1324
1325 (% aria-label="image-20220602171200-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602171200-8.png||data-widget="image" height="567" width="1007"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
1326
1327 (% title="Click and drag to resize" %)​
1328
1329 (((
1330 To enable the listening mode, use can run the command (% style="color:#4472c4" %)** AT+RXMODE**.
1331 )))
1332
1333
1334
1335 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
1336 |=(% style="width: 156px; background-color:#D9E2F3;color:#0070C0" %)(((
1337 **Command example**
1338 )))|=(% style="width: 355px; background-color:#D9E2F3;color:#0070C0" %)(((
1339 **Function**
1340 )))
1341 |(% style="width:156px" %)(((
1342 AT+RXMODE=1,10
1343 )))|(% style="width:352px" %)(((
1344 Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1345 )))
1346 |(% style="width:156px" %)(((
1347 AT+RXMODE=2,500
1348 )))|(% style="width:352px" %)(((
1349 Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1350 )))
1351 |(% style="width:156px" %)(((
1352 AT+RXMODE=0,0
1353 )))|(% style="width:352px" %)(((
1354 Disable listening mode. This is the default settings.
1355 )))
1356 |(% style="width:156px" %)(((
1357
1358 )))|(% style="width:352px" %)(((
1359 A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1360 )))
1361
1362 (((
1363
1364
1365 (% style="color:#037691" %)**Downlink Command:**
1366 )))
1367
1368 (((
1369 (% style="color:#4472c4" %)** 0xA6 aa bb cc **(%%) same as AT+RXMODE=aa,(bb<<8 | cc)
1370 )))
1371
1372 (((
1373
1374 )))
1375
1376 (((
1377 **Example**:
1378 )))
1379
1380 (((
1381 The RS485-LN is set to AT+RXMODE=2,1000
1382 )))
1383
1384 (((
1385 There is a two Modbus commands in the RS485 network as below:
1386 )))
1387
1388 (((
1389 The Modbus master send a command: (% style="background-color:#ffc000" %)**01 03 00 00 00 02 c4 0b**
1390 )))
1391
1392 (((
1393 And Modbus slave reply with: (% style="background-color:green" %)**01 03 04 00 00 00 00 fa 33**
1394 )))
1395
1396 (((
1397 RS485-LN will capture both and send the uplink: (% style="background-color:#ffc000" %)**01 03 00 00 00 02 c4 0b  **(% style="background-color:green" %)**01 03 04 00 00 00 00 fa 33**
1398
1399
1400 )))
1401
1402 (((
1403 (% aria-label="image-20220602171200-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602171200-9.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1404 )))
1405
1406
1407
1408 (((
1409 (% style="color:red" %)**Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.**
1410 )))
1411
1412
1413 == 3.7 Buttons ==
1414
1415
1416 (% border="1.5" cellspacing="4" style="background-color:#f2f2f2; width:430px" %)
1417 |=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**Button**|=(% style="width: 380px;background-color:#D9E2F3;color:#0070C0" %)**Feature**
1418 |(% style="width:50px" %)ACT|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1419 |(% style="width:50px" %)RST|(% style="width:361px" %)Reboot RS485
1420 |(% style="width:50px" %)PRO|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1421
1422 == 3.8 LEDs ==
1423
1424
1425 (% border="1.5" cellspacing="4" style="background-color:#f2f2f2; width:430px" %)
1426 |=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**LEDs**|=(% style="width: 380px;background-color:#D9E2F3;color:#0070C0" %)**Feature**
1427 |PWR|Always on if there is power
1428 |SYS|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1429
1430 = 4. Case Study =
1431
1432
1433 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1434
1435
1436 = 5. Use AT Command =
1437
1438 == 5.1 Access AT Command ==
1439
1440
1441 (((
1442 RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below.
1443
1444
1445 )))
1446
1447 (% aria-label="1654162355560-817.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162355560-817.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1448
1449
1450
1451 (((
1452 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-LN. The default password is 123456. Below is the output for reference:
1453
1454
1455 )))
1456
1457 (% aria-label="1654162368066-342.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162368066-342.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1458
1459
1460 (((
1461 More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1462 )))
1463
1464
1465 == 5.2 Common AT Command Sequence ==
1466
1467 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1468
1469
1470 If device has not joined network yet:
1471
1472 * (% style="color:#037691" %)**AT+FDR**
1473 * (% style="color:#037691" %)**AT+NJM=0**
1474 * (% style="color:#037691" %)**ATZ**
1475
1476 (((
1477
1478
1479 If device already joined network:
1480
1481 * (% style="color:#037691" %)**AT+NJM=0**
1482 * (% style="color:#037691" %)**ATZ**
1483 )))
1484
1485
1486
1487 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1488
1489
1490 (% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1491
1492 (% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode
1493
1494 (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off
1495
1496 (% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%) Set Data Rate
1497
1498 (% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1499
1500 (% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%)  Set transmit frequency to 868.4Mhz
1501
1502 (% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1503
1504 (% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1505
1506 (% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1507
1508 (% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1509
1510
1511 (% style="color:red" %)**Note:**
1512
1513 (((
1514 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1515 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1516 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1517 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1518
1519
1520 )))
1521
1522 (% aria-label="1654162478620-421.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162478620-421.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1523
1524
1525 = 6. FAQ =
1526
1527 == 6.1 How to upgrade the image? ==
1528
1529
1530 (((
1531 The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1532 )))
1533
1534 * (((
1535 Support new features
1536 )))
1537 * (((
1538 For bug fix
1539 )))
1540 * (((
1541 Change LoRaWAN bands.
1542 )))
1543
1544 (((
1545 Below shows the hardware connection for how to upload an image to RS485-LN:
1546 )))
1547
1548 (% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
1549
1550 (% title="Click and drag to resize" %)​
1551
1552 (((
1553 (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1554
1555
1556 )))
1557
1558 (((
1559 (% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACP33wo_ZQLsxW2MJ70oUoba/RS485-LN/Firmware?dl=0&subfolder_nav_tracking=1]].
1560
1561
1562 )))
1563
1564 (((
1565 (% style="color:blue" %)**Step3**(%%)**: **Open flashloader; choose the correct COM port to update.
1566
1567
1568 )))
1569
1570 (((
1571 (((
1572 (((
1573 (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1574 )))
1575 )))
1576 )))
1577
1578
1579 (% aria-label="image-20220602175818-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175818-12.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1580
1581
1582 (% aria-label="image-20220602175848-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175848-13.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1583
1584
1585 (% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1586
1587
1588 (% style="color:red" %)**Notice**: **In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:**
1589
1590 (% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1591
1592
1593 == 6.2 How to change the LoRa Frequency Bands/Region? ==
1594
1595
1596 User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1597
1598
1599 == 6.3 How many RS485-Slave can RS485-LN connects? ==
1600
1601
1602 The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1603
1604
1605 == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
1606
1607
1608 When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1609
1610 Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1611
1612
1613 == 6.5 Can i use point to point communication for RS485-LN? ==
1614
1615
1616 Yes, please updating point-to-point [[firmware>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACP33wo_ZQLsxW2MJ70oUoba/RS485-LN/Firmware?dl=0&subfolder_nav_tracking=1]],then refer [[Point to Point Communication for RS485-LN>>Point to Point Communication for RS485-LN]].
1617
1618
1619 == 6.6 How to Use RS485-LN  to connect to RS232 devices? ==
1620
1621
1622 [[Use RS485-BL or RS485-LN to connect to RS232 devices. - DRAGINO>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/RS485%20to%20RS232/]]
1623
1624
1625 == 6.7 How to judge whether there is a problem with the set COMMAND ==
1626
1627 === 6.7.1 Introduce: ===
1628
1629
1630 Users can use below the structure to fast debug the communication between RS485BL and RS485-LN. The principle is to put the PC in the RS485 network and sniff the packet between Modbus MTU and RS485-BL/LN. We can use this way to:
1631
1632 1. Test if Modbus-MTU works with PC commands.
1633 1. Check if RS485-LN sent the expected command to Mobus-MTU
1634 1. Check if Modbus-MTU return back the expected result to RS485-LN.
1635 1. If both b) and c) has issue, we can compare PC’s output and RS485-LN output.
1636
1637 [[image:image-20221130104310-1.png||height="380" width="680"]]
1638
1639
1640 Example Connection:
1641
1642 [[image:image-20221130104310-2.png]]
1643
1644
1645 === 6.7.2 Set up PC to monitor RS485 network With Serial tool ===
1646
1647
1648 (% style="color:red" %)**Note: Receive and send set to hex mode**
1649
1650 [[image:image-20221130104310-3.png||height="616" width="714"]]
1651
1652
1653 === 6.7.3 With ModRSsim2: ===
1654
1655
1656 (% style="color:blue" %)**(1) Select serial port MODBUS RS-232**
1657
1658 [[image:image-20221130104310-4.png||height="390" width="865"]]
1659
1660
1661 (% style="color:blue" %)**(2) Click the serial port icon**
1662
1663 [[image:image-20221130104310-5.png||height="392" width="870"]]
1664
1665
1666 (% style="color:blue" %)**(3) After selecting the correct serial port and baud rate, click ok**
1667
1668 [[image:image-20221130104310-6.png]]
1669
1670
1671 (% style="color:blue" %)**(4) Click the comms.**
1672
1673 [[image:image-20221130104310-7.png||height="376" width="835"]]
1674
1675 (% class="wikigeneratedid" id="HRunRS485-LN2FBLcommandandmonitorifitiscorrect." %)
1676 **Run RS485-LN/BL command and monitor if it is correct.**
1677
1678
1679 === 6.7.4 Example – Test the CFGDEV command ===
1680
1681
1682 RS485-LN sent below command:
1683
1684 (% style="color:blue" %)**AT+CFGDEV=01 03 00 20 00 01,1**(%%) to RS485 network, and PC is able to get this command and return commands from MTU to show in the serial tool.
1685
1686
1687 We can see the output from the Serial port tool to analyze. And check if they are expected result.
1688
1689 [[image:image-20221130104310-8.png||height="214" width="797"]]
1690
1691
1692 We can also use (% style="color:blue" %)**ModRSsim2**(%%) to see the output.
1693
1694 [[image:image-20221130104310-9.png||height="531" width="729"]]
1695
1696
1697 === 6.7.5 Example – Test CMD command sets. ===
1698
1699
1700 Run (% style="color:blue" %)**AT+SENSORVALUE=1**(%%) to test the CMD commands set in RS485-LN.
1701
1702
1703 (% style="color:blue" %)**Serial port tool:**
1704
1705 [[image:image-20221130104310-10.png||height="339" width="844"]]
1706
1707
1708 (% style="color:blue" %)**ModRSsim2:**
1709
1710 [[image:image-20221130104310-11.png||height="281" width="962"]]
1711
1712
1713 === 6.7.6 Test with PC ===
1714
1715
1716 If there is still have problem to set up correctly the commands between RS485-LN and MTU. User can test the correct RS485 command set in PC and compare with the RS485 command sent out via RS485-LN. as long as both commands are the same, the MTU should return correct result.
1717
1718
1719 Or User can send the working commands set in PC serial tool to Dragino Support to check what should be configured in RS485-LN.
1720
1721 (% style="color:blue" %)**Connection method:**
1722
1723 [[image:image-20221130104310-12.png]]
1724
1725
1726 (% style="color:blue" %)**Link situation:**
1727
1728 [[image:image-20221130104310-13.png||height="458" width="486"]]
1729
1730
1731 [[image:image-20221130104310-14.png||height="371" width="823"]]
1732
1733
1734 == 6.8 Where to get the decoder for RS485-LN? ==
1735
1736
1737 The decoder for RS485-LN needs to be written by yourself. Because the sensor to which the user is connected is custom, the read device data bytes also need custom parsing, so there is no universal decoder. We can only provide [[templates>>https://github.com/dragino/dragino-end-node-decoder/tree/main/RS485-LN]] for decoders (no intermediate data parsing part involved)
1738
1739
1740 = 7. Trouble Shooting =
1741
1742 == 7.1 Downlink doesn't work, how to solve it? ==
1743
1744
1745 Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1746
1747
1748 == 7.2 Why I can't join TTN V3 in US915 /AU915 bands? ==
1749
1750
1751 It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1752
1753
1754 = 8. Order Info =
1755
1756
1757 (% style="color:blue" %)**Part Number: RS485-LN-XXX**
1758
1759 (% style="color:blue" %)**XXX:**
1760
1761 * (% style="color:red" %)**EU433**(%%):  frequency bands EU433
1762 * (% style="color:red" %)**EU868**(%%):  frequency bands EU868
1763 * (% style="color:red" %)**KR920**(%%):  frequency bands KR920
1764 * (% style="color:red" %)**CN470**(%%):  frequency bands CN470
1765 * (% style="color:red" %)**AS923**(%%):  frequency bands AS923
1766 * (% style="color:red" %)**AU915**(%%):  frequency bands AU915
1767 * (% style="color:red" %)**US915**(%%):  frequency bands US915
1768 * (% style="color:red" %)**IN865**(%%):  frequency bands IN865
1769 * (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1770 * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1771
1772 = 9. Packing Info =
1773
1774
1775 **Package Includes**:
1776
1777 * RS485-LN x 1
1778 * Stick Antenna for LoRa RF part x 1
1779 * Program cable x 1
1780
1781 **Dimension and weight**:
1782
1783 * Device Size: 13.5 x 7 x 3 cm
1784 * Device Weight: 105g
1785 * Package Size / pcs : 14.5 x 8 x 5 cm
1786 * Weight / pcs : 170g
1787
1788 = 10. FCC Caution for RS485LN-US915 =
1789
1790
1791 (((
1792 Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1793 )))
1794
1795 (((
1796 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1797 )))
1798
1799 (((
1800
1801 )))
1802
1803 (((
1804 (% style="color:red" %)**IMPORTANT NOTE:**
1805 )))
1806
1807 (((
1808 (% style="color:red" %)**Note: **(%%)This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1809 )))
1810
1811 (((
1812 —Reorient or relocate the receiving antenna.
1813 )))
1814
1815 (((
1816 —Increase the separation between the equipment and receiver.
1817 )))
1818
1819 (((
1820 —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
1821 )))
1822
1823 (((
1824 —Consult the dealer or an experienced radio/TV technician for help.
1825 )))
1826
1827 (((
1828
1829 )))
1830
1831 (((
1832 (% style="color:red" %)**FCC Radiation Exposure Statement:**
1833 )))
1834
1835 (((
1836 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
1837 )))
1838
1839
1840 = 11. Support =
1841
1842
1843 * (((
1844 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1845 )))
1846 * (((
1847 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
1848
1849
1850
1851 )))
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved