<
From version < 99.1 >
edited by Bei Jinggeng
on 2022/12/06 09:48
To version < 102.2 >
edited by Xiaoling
on 2023/04/25 09:31
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -28,7 +28,7 @@
28 28  
29 29  
30 30  
31 -= 1.Introduction =
31 += 1. Introduction =
32 32  
33 33  == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
34 34  
... ... @@ -122,7 +122,6 @@
122 122  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
123 123  
124 124  
125 -
126 126  == 1.6 Hardware Change log ==
127 127  
128 128  
... ... @@ -283,12 +283,12 @@
283 283  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
284 284  
285 285  
286 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %)
287 -|=(% style="width: 110px;" %)(((
285 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
286 +|=(% style="width: 120px;background-color:#D9E2F3;color:#0070C0" %)(((
288 288  **AT Commands**
289 -)))|=(% style="width: 210px;" %)(((
288 +)))|=(% style="width: 200px;background-color:#D9E2F3;color:#0070C0" %)(((
290 290  **Description**
291 -)))|=(% style="width: 190px;" %)(((
290 +)))|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)(((
292 292  **Example**
293 293  )))
294 294  |(% style="width:110px" %)(((
... ... @@ -605,7 +605,6 @@
605 605  )))
606 606  
607 607  
608 -
609 609  === 3.5.1 Common Commands ===
610 610  
611 611  
... ... @@ -751,7 +751,6 @@
751 751  
752 752  
753 753  
754 -
755 755  ==== (% style="color:blue" %)**Set Payload version**(%%) ====
756 756  
757 757  
... ... @@ -794,7 +794,6 @@
794 794  
795 795  
796 796  
797 -
798 798  ==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ====
799 799  
800 800  
... ... @@ -879,7 +879,6 @@
879 879  
880 880  
881 881  
882 -
883 883  ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
884 884  
885 885  
... ... @@ -923,7 +923,6 @@
923 923  
924 924  
925 925  
926 -
927 927  ==== (% style="color:blue" %)**RS485 command timeout**(%%) ====
928 928  
929 929  
... ... @@ -960,7 +960,7 @@
960 960  )))
961 961  
962 962  (((
963 -(% style="color:#4472c4" %)** 0x AA aa bb cc**(%%) Same as: AT+CMDDLaa=hex(bb cc)*1000
957 +(% style="color:#4472c4" %)** 0x AA aa bb cc**(%%) Same as: AT+CMDDLaa=hex (bb cc)
964 964  )))
965 965  
966 966  (((
... ... @@ -970,12 +970,11 @@
970 970  )))
971 971  
972 972  (((
973 -**0xAA 01 00 01**  ~-~-> Same as  **AT+CMDDL1=1000 ms**
967 +**0xAA 01 03 E8**  ~-~-> Same as  **AT+CMDDL1=1000 ms**
974 974  )))
975 975  
976 976  
977 977  
978 -
979 979  ==== (% style="color:blue" %)**Uplink payload mode**(%%) ====
980 980  
981 981  
... ... @@ -1030,7 +1030,6 @@
1030 1030  
1031 1031  
1032 1032  
1033 -
1034 1034  ==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ====
1035 1035  
1036 1036  
... ... @@ -1060,7 +1060,6 @@
1060 1060  
1061 1061  
1062 1062  
1063 -
1064 1064  ==== (% style="color:blue" %)**Clear RS485 Command**(%%) ====
1065 1065  
1066 1066  
... ... @@ -1109,7 +1109,6 @@
1109 1109  
1110 1110  
1111 1111  
1112 -
1113 1113  ==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ====
1114 1114  
1115 1115  
... ... @@ -1193,7 +1193,7 @@
1193 1193  
1194 1194  
1195 1195  
1196 -==== (% style="color:blue" %)**Encrypted payload**(%%) ====
1186 +==== (% style="color:blue" %)**Encrypted payload(Since Version 1.4.0)**(%%) ====
1197 1197  
1198 1198  (((
1199 1199  
... ... @@ -1209,10 +1209,9 @@
1209 1209  
1210 1210  
1211 1211  
1202 +==== (% style="color:blue" %)**Get sensor value(Since Version 1.4.0)**(%%) ====
1212 1212  
1213 -==== (% style="color:blue" %)**Get sensor value**(%%) ====
1214 1214  
1215 -
1216 1216  * (((
1217 1217  (% style="color:#037691" %)** AT Command:**
1218 1218  )))
... ... @@ -1223,10 +1223,9 @@
1223 1223  
1224 1224  
1225 1225  
1215 +==== (% style="color:blue" %)**Resets the downlink packet count(Since Version 1.4.0)**(%%) ====
1226 1226  
1227 -==== (% style="color:blue" %)**Resets the downlink packet count**(%%) ====
1228 1228  
1229 -
1230 1230  * (((
1231 1231  (% style="color:#037691" %)** AT Command:**
1232 1232  )))
... ... @@ -1237,10 +1237,9 @@
1237 1237  
1238 1238  
1239 1239  
1228 +==== (% style="color:blue" %)**When the limit bytes are exceeded, upload in batches(Since Version 1.4.0)**(%%) ====
1240 1240  
1241 -==== (% style="color:blue" %)**When the limit bytes are exceeded, upload in batches**(%%) ====
1242 1242  
1243 -
1244 1244  * (((
1245 1245  (% style="color:#037691" %)** AT Command:**
1246 1246  )))
... ... @@ -1258,10 +1258,9 @@
1258 1258  
1259 1259  
1260 1260  
1248 +==== (% style="color:blue" %)**Copy downlink to uplink (Since Version 1.4.0)**(%%) ====
1261 1261  
1262 -==== (% style="color:blue" %)** Copy downlink to uplink **(%%) ====
1263 1263  
1264 -
1265 1265  * (((
1266 1266  (% style="color:#037691" %)** AT Command:**
1267 1267  )))
... ... @@ -1283,10 +1283,9 @@
1283 1283  
1284 1284  
1285 1285  
1272 +==== (% style="color:blue" %)**Query version number and frequency band 、TDC(Since Version 1.4.0)**(%%) ====
1286 1286  
1287 -==== (% style="color:blue" %)**Query version number and frequency band 、TDC**(%%) ====
1288 1288  
1289 -
1290 1290  (((
1291 1291  * (% style="color:#037691" %)**Downlink Payload:**
1292 1292  
... ... @@ -1301,10 +1301,9 @@
1301 1301  
1302 1302  
1303 1303  
1289 +==== (% style="color:blue" %)** Monitor RS485 communication of other devices(Since Version 1.4.0)**(%%) ====
1304 1304  
1305 -==== (% style="color:blue" %)** Monitor RS485 communication of other devices**(%%) ====
1306 1306  
1307 -
1308 1308  * (((
1309 1309  (% style="color:#037691" %)** AT Command:**
1310 1310  )))
... ... @@ -1502,8 +1502,6 @@
1502 1502  
1503 1503  * (% style="color:#037691" %)**AT+NJM=0**
1504 1504  * (% style="color:#037691" %)**ATZ**
1505 -
1506 -
1507 1507  )))
1508 1508  
1509 1509  
... ... @@ -1705,7 +1705,7 @@
1705 1705  
1706 1706  RS485-LN sent below command:
1707 1707  
1708 -(% style="color:blue" %)**AT+CFGDEV=01 03 20 00 01 85 c0,1**(%%) to RS485 network, and PC is able to get this command and return commands from MTU to show in the serial tool.
1690 +(% style="color:blue" %)**AT+CFGDEV=01 03 00 20 00 01,1**(%%) to RS485 network, and PC is able to get this command and return commands from MTU to show in the serial tool.
1709 1709  
1710 1710  
1711 1711  We can see the output from the Serial port tool to analyze. And check if they are expected result.
... ... @@ -1757,6 +1757,7 @@
1757 1757  
1758 1758  == 6.8 Where to get the decoder for RS485-LN? ==
1759 1759  
1742 +
1760 1760  The decoder for RS485-LN needs to be written by yourself. Because the sensor to which the user is connected is custom, the read device data bytes also need custom parsing, so there is no universal decoder. We can only provide [[templates>>https://github.com/dragino/dragino-end-node-decoder/tree/main/RS485-LN]] for decoders (no intermediate data parsing part involved)
1761 1761  
1762 1762  
... ... @@ -1792,7 +1792,7 @@
1792 1792  * (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1793 1793  * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1794 1794  
1795 -= 9.Packing Info =
1778 += 9. Packing Info =
1796 1796  
1797 1797  
1798 1798  **Package Includes**:
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0