<
From version < 98.1 >
edited by Bei Jinggeng
on 2022/12/06 09:45
To version < 99.1 >
edited by Bei Jinggeng
on 2022/12/06 09:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -94,7 +94,6 @@
94 94  * Automatic RF Sense and CAD with ultra-fast AFC.
95 95  * Packet engine up to 256 bytes with CRC
96 96  
97 -
98 98  == 1.3 Features ==
99 99  
100 100  
... ... @@ -107,7 +107,6 @@
107 107  * Support Modbus protocol
108 108  * Support Interrupt uplink (Since hardware version v1.2)
109 109  
110 -
111 111  == 1.4 Applications ==
112 112  
113 113  
... ... @@ -118,7 +118,6 @@
118 118  * Smart Cities
119 119  * Smart Factory
120 120  
121 -
122 122  == 1.5 Firmware Change log ==
123 123  
124 124  
... ... @@ -344,7 +344,6 @@
344 344  )))
345 345  )))
346 346  
347 -
348 348  === 3.3.2 Configure sensors ===
349 349  
350 350  
... ... @@ -372,7 +372,6 @@
372 372  )))
373 373  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
374 374  
375 -
376 376  === 3.3.3 Configure read commands for each sampling ===
377 377  
378 378  
... ... @@ -1446,7 +1446,6 @@
1446 1446  |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1447 1447  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1448 1448  
1449 -
1450 1450  == 3.8 LEDs ==
1451 1451  
1452 1452  
... ... @@ -1455,7 +1455,6 @@
1455 1455  |**PWR**|Always on if there is power
1456 1456  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1457 1457  
1458 -
1459 1459  = 4. Case Study =
1460 1460  
1461 1461  
... ... @@ -1764,7 +1764,7 @@
1764 1764  
1765 1765  == 6.8 Where to get the decoder for RS485-LN? ==
1766 1766  
1767 -The decoder for RS485-LN needs to be written by yourself. Because the sensor to which the user is connected is custom, the read device data bytes also need custom parsing, so there is no universal decoder. We can only provide templates for decoders (no intermediate data parsing part involved)
1760 +The decoder for RS485-LN needs to be written by yourself. Because the sensor to which the user is connected is custom, the read device data bytes also need custom parsing, so there is no universal decoder. We can only provide [[templates>>https://github.com/dragino/dragino-end-node-decoder/tree/main/RS485-LN]] for decoders (no intermediate data parsing part involved)
1768 1768  
1769 1769  
1770 1770  = 7. Trouble Shooting =
... ... @@ -1799,7 +1799,6 @@
1799 1799  * (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1800 1800  * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1801 1801  
1802 -
1803 1803  = 9.Packing Info =
1804 1804  
1805 1805  
... ... @@ -1816,7 +1816,6 @@
1816 1816  * Package Size / pcs : 14.5 x 8 x 5 cm
1817 1817  * Weight / pcs : 170g
1818 1818  
1819 -
1820 1820  = 10. FCC Caution for RS485LN-US915 =
1821 1821  
1822 1822  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0