<
From version < 97.1 >
edited by Bei Jinggeng
on 2022/11/30 10:55
To version < 95.1 >
edited by Bei Jinggeng
on 2022/11/30 10:47
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -96,6 +96,7 @@
96 96  * Automatic RF Sense and CAD with ultra-fast AFC.
97 97  * Packet engine up to 256 bytes with CRC
98 98  
99 +
99 99  == 1.3 Features ==
100 100  
101 101  
... ... @@ -108,6 +108,7 @@
108 108  * Support Modbus protocol
109 109  * Support Interrupt uplink (Since hardware version v1.2)
110 110  
112 +
111 111  == 1.4 Applications ==
112 112  
113 113  
... ... @@ -118,6 +118,7 @@
118 118  * Smart Cities
119 119  * Smart Factory
120 120  
123 +
121 121  == 1.5 Firmware Change log ==
122 122  
123 123  
... ... @@ -349,6 +349,7 @@
349 349  )))
350 350  )))
351 351  
355 +
352 352  === 3.3.2 Configure sensors ===
353 353  
354 354  
... ... @@ -376,6 +376,7 @@
376 376  )))
377 377  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
378 378  
383 +
379 379  === 3.3.3 Configure read commands for each sampling ===
380 380  
381 381  
... ... @@ -1459,6 +1459,7 @@
1459 1459  |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1460 1460  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1461 1461  
1467 +
1462 1462  == 3.8 LEDs ==
1463 1463  
1464 1464  
... ... @@ -1467,6 +1467,7 @@
1467 1467  |**PWR**|Always on if there is power
1468 1468  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1469 1469  
1476 +
1470 1470  = 4. Case Study =
1471 1471  
1472 1472  
... ... @@ -1677,7 +1677,7 @@
1677 1677  
1678 1678  == 6.7 How to judge whether there is a problem with the set COMMAND ==
1679 1679  
1680 -=== 6.7.1 Introduce: ===
1687 += Introduce: =
1681 1681  
1682 1682  
1683 1683  Users can use below the structure to fast debug the communication between RS485BL and RS485-LN. The principle is to put the PC in the RS485 network and sniff the packet between Modbus MTU and RS485-BL/LN. We can use this way to:
... ... @@ -1695,14 +1695,16 @@
1695 1695  [[image:image-20221130104310-2.png]]
1696 1696  
1697 1697  
1698 -=== 6.7.2 Set up PC to monitor RS485 network With Serial tool ===
1705 += Set up PC to monitor RS485 network =
1699 1699  
1707 +== With Serial tool ==
1708 +
1700 1700  Note: Receive and send set to hex mode
1701 1701  
1702 1702  [[image:image-20221130104310-3.png||height="616" width="714"]]
1703 1703  
1704 1704  
1705 -=== 6.7.3 With ModRSsim2: ===
1714 +== With ModRSsim2: ==
1706 1706  
1707 1707  (1)Select serial port MODBUS RS-232
1708 1708  
... ... @@ -1722,12 +1722,10 @@
1722 1722  
1723 1723  [[image:image-20221130104310-7.png||height="376" width="835"]]
1724 1724  
1725 -(% class="wikigeneratedid" id="HRunRS485-LN2FBLcommandandmonitorifitiscorrect." %)
1726 -Run RS485-LN/BL command and monitor if it is correct.
1734 += Run RS485-LN/BL command and monitor if it is correct. =
1727 1727  
1736 +== Example – Test the CFGDEV command ==
1728 1728  
1729 -=== 6.7.4 Example – Test the CFGDEV command ===
1730 -
1731 1731  RS485-LN sent below command:
1732 1732  
1733 1733  AT+CFGDEV=01 03 20 00 01 85 c0,1 to RS485 network, and PC is able to get this command and return commands from MTU to show in the serial tool.
... ... @@ -1743,7 +1743,7 @@
1743 1743  
1744 1744  
1745 1745  
1746 -=== 6.7.5 Example – Test CMD command sets. ===
1753 +== Example – Test CMD command sets. ==
1747 1747  
1748 1748  Run AT+SENSORVALUE=1 to test the CMD commands set in RS485-LN.
1749 1749  
... ... @@ -1758,7 +1758,7 @@
1758 1758  
1759 1759  
1760 1760  
1761 -=== 6.7.6 Test with PC ===
1768 += **Test with PC** =
1762 1762  
1763 1763  If there is still have problem to set up correctly the commands between RS485-LN and MTU. User can test the correct RS485 command set in PC and compare with the RS485 command sent out via RS485-LN. as long as both commands are the same, the MTU should return correct result.
1764 1764  
... ... @@ -1775,7 +1775,6 @@
1775 1775  
1776 1776  [[image:image-20221130104310-14.png||height="371" width="823"]]
1777 1777  
1778 -
1779 1779  = 7. Trouble Shooting =
1780 1780  
1781 1781  
... ... @@ -1811,6 +1811,7 @@
1811 1811  * (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1812 1812  * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1813 1813  
1820 +
1814 1814  = 9.Packing Info =
1815 1815  
1816 1816  
... ... @@ -1827,6 +1827,7 @@
1827 1827  * Package Size / pcs : 14.5 x 8 x 5 cm
1828 1828  * Weight / pcs : 170g
1829 1829  
1837 +
1830 1830  = 10. FCC Caution for RS485LN-US915 =
1831 1831  
1832 1832  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0