Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1677,7 +1677,7 @@ 1677 1677 1678 1678 == 6.7 How to judge whether there is a problem with the set COMMAND == 1679 1679 1680 -=== Introduce: === 1680 +=== 6.7.1 Introduce: === 1681 1681 1682 1682 1683 1683 Users can use below the structure to fast debug the communication between RS485BL and RS485-LN. The principle is to put the PC in the RS485 network and sniff the packet between Modbus MTU and RS485-BL/LN. We can use this way to: ... ... @@ -1695,16 +1695,14 @@ 1695 1695 [[image:image-20221130104310-2.png]] 1696 1696 1697 1697 1698 -=== Set up PC to monitor RS485 network === 1698 +=== 6.7.2 Set up PC to monitor RS485 network With Serial tool === 1699 1699 1700 -=== With Serial tool === 1701 - 1702 1702 Note: Receive and send set to hex mode 1703 1703 1704 1704 [[image:image-20221130104310-3.png||height="616" width="714"]] 1705 1705 1706 1706 1707 -=== With ModRSsim2: === 1705 +=== 6.7.3 With ModRSsim2: === 1708 1708 1709 1709 (1)Select serial port MODBUS RS-232 1710 1710 ... ... @@ -1724,10 +1724,12 @@ 1724 1724 1725 1725 [[image:image-20221130104310-7.png||height="376" width="835"]] 1726 1726 1727 -=== Run RS485-LN/BL command and monitor if it is correct. === 1725 +(% class="wikigeneratedid" id="HRunRS485-LN2FBLcommandandmonitorifitiscorrect." %) 1726 +Run RS485-LN/BL command and monitor if it is correct. 1728 1728 1729 -=== Example – Test the CFGDEV command === 1730 1730 1729 +=== 6.7.4 Example – Test the CFGDEV command === 1730 + 1731 1731 RS485-LN sent below command: 1732 1732 1733 1733 AT+CFGDEV=01 03 20 00 01 85 c0,1 to RS485 network, and PC is able to get this command and return commands from MTU to show in the serial tool. ... ... @@ -1743,7 +1743,7 @@ 1743 1743 1744 1744 1745 1745 1746 -=== Example – Test CMD command sets. === 1746 +=== 6.7.5 Example – Test CMD command sets. === 1747 1747 1748 1748 Run AT+SENSORVALUE=1 to test the CMD commands set in RS485-LN. 1749 1749 ... ... @@ -1758,7 +1758,7 @@ 1758 1758 1759 1759 1760 1760 1761 -=== Test with PC === 1761 +=== 6.7.6 Test with PC === 1762 1762 1763 1763 If there is still have problem to set up correctly the commands between RS485-LN and MTU. User can test the correct RS485 command set in PC and compare with the RS485 command sent out via RS485-LN. as long as both commands are the same, the MTU should return correct result. 1764 1764 ... ... @@ -1775,6 +1775,7 @@ 1775 1775 1776 1776 [[image:image-20221130104310-14.png||height="371" width="823"]] 1777 1777 1778 + 1778 1778 = 7. Trouble Shooting = 1779 1779 1780 1780