96 96  * Automatic RF Sense and CAD with ultra-fast AFC.
97 97  * Packet engine up to 256 bytes with CRC
98 98  
99 -
100 100  == 1.3 Features ==
101 101  
102 102  
... ... @@ -109,7 +109,6 @@
109 109  * Support Modbus protocol
110 110  * Support Interrupt uplink (Since hardware version v1.2)
111 111  
112 -
113 113  == 1.4 Applications ==
114 114  
115 115  
... ... @@ -120,7 +120,6 @@
120 120  * Smart Cities
121 121  * Smart Factory
122 122  
123 -
124 124  == 1.5 Firmware Change log ==
125 125  
126 126  
... ... @@ -352,7 +352,6 @@
352 352  )))
353 353  )))
354 354  
355 -
356 356  === 3.3.2 Configure sensors ===
357 357  
358 358  
... ... @@ -380,7 +380,6 @@
380 380  )))
381 381  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
382 382  
383 -
384 384  === 3.3.3 Configure read commands for each sampling ===
385 385  
386 386  
... ... @@ -1464,7 +1464,6 @@
1464 1464  |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1465 1465  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1466 1466  
1467 -
1468 1468  == 3.8 LEDs ==
1469 1469  
1470 1470  
... ... @@ -1473,7 +1473,6 @@
1473 1473  |**PWR**|Always on if there is power
1474 1474  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1475 1475  
1476 -
1477 1477  = 4. Case Study =
1478 1478  
1479 1479  
... ... @@ -1684,7 +1684,7 @@
1684 1684  
1685 1685  == 6.7 How to judge whether there is a problem with the set COMMAND ==
1686 1686  
1687 -= Introduce: =
1680 +=== 6.7.1 Introduce: ===
1688 1688  
1689 1689  
1690 1690  Users can use below the structure to fast debug the communication between RS485BL and RS485-LN. The principle is to put the PC in the RS485 network and sniff the packet between Modbus MTU and RS485-BL/LN. We can use this way to:
... ... @@ -1702,16 +1702,14 @@
1702 1702  [[image:image-20221130104310-2.png]]
1703 1703  
1704 1704  
1705 -= Set up PC to monitor RS485 network =
1698 +=== 6.7.2 Set up PC to monitor RS485 network With Serial tool ===
1706 1706  
1707 -== With Serial tool ==
1708 -
1709 1709  Note: Receive and send set to hex mode
1710 1710  
1711 1711  [[image:image-20221130104310-3.png||height="616" width="714"]]
1712 1712  
1713 1713  
1714 -== With ModRSsim2: ==
1705 +=== 6.7.3 With ModRSsim2: ===
1715 1715  
1716 1716  (1)Select serial port MODBUS RS-232
1717 1717  
... ... @@ -1731,10 +1731,12 @@
1731 1731  
1732 1732  [[image:image-20221130104310-7.png||height="376" width="835"]]
1733 1733  
1734 -= Run RS485-LN/BL command and monitor if it is correct. =
1725 +(% class="wikigeneratedid" id="HRunRS485-LN2FBLcommandandmonitorifitiscorrect." %)
1726 +Run RS485-LN/BL command and monitor if it is correct.
1735 1735  
1736 -== Example – Test the CFGDEV command ==
1737 1737  
1729 +=== 6.7.4 Example – Test the CFGDEV command ===
1730 +
1738 1738  RS485-LN sent below command:
1739 1739  
1740 1740  AT+CFGDEV=01 03 20 00 01 85 c0,1 to RS485 network, and PC is able to get this command and return commands from MTU to show in the serial tool.
... ... @@ -1750,7 +1750,7 @@
1750 1750  
1751 1751  
1752 1752  
1753 -== Example – Test CMD command sets. ==
1746 +=== 6.7.5 Example – Test CMD command sets. ===
1754 1754  
1755 1755  Run AT+SENSORVALUE=1 to test the CMD commands set in RS485-LN.
1756 1756  
... ... @@ -1765,7 +1765,7 @@
1765 1765  
1766 1766  
1767 1767  
1768 -= **Test with PC** =
1761 +=== 6.7.6 Test with PC ===
1769 1769  
1770 1770  If there is still have problem to set up correctly the commands between RS485-LN and MTU. User can test the correct RS485 command set in PC and compare with the RS485 command sent out via RS485-LN. as long as both commands are the same, the MTU should return correct result.
1771 1771  
... ... @@ -1782,6 +1782,7 @@
1782 1782  
1783 1783  [[image:image-20221130104310-14.png||height="371" width="823"]]
1784 1784  
1778 +
1785 1785  = 7. Trouble Shooting =
1786 1786  
1787 1787  
... ... @@ -1817,7 +1817,6 @@
1817 1817  * (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1818 1818  * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1819 1819  
1820 -
1821 1821  = 9.Packing Info =
1822 1822  
1823 1823  
... ... @@ -1834,7 +1834,6 @@
1834 1834  * Package Size / pcs : 14.5 x 8 x 5 cm
1835 1835  * Weight / pcs : 170g
1836 1836  
1837 -
1838 1838  = 10. FCC Caution for RS485LN-US915 =
1839 1839  
1840 1840  