34 34  == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
35 35  
36 -
37 37  (((
37 +(((
38 +(((
39 +
40 +
38 38  The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
39 39  )))
43 +)))
40 40  
41 41  (((
46 +(((
42 42  RS485-LN allows user to (% style="color:blue" %)**monitor / control RS485 devices**(%%) and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
43 43  )))
49 +)))
44 44  
45 45  (((
52 +(((
46 46  (% style="color:blue" %)**For data uplink**(%%), RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server.
47 47  )))
55 +)))
48 48  
49 49  (((
58 +(((
50 50  (% style="color:blue" %)**For data downlink**(%%), RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices.
51 51  )))
52 52  
53 53  (((
54 54  (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]]
64 +
65 +
55 55  )))
67 +)))
68 +)))
56 56  
57 -
58 58  (% aria-label="1653267211009-519.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653267211009-519.png||data-widget="image" height="419" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
59 59  
60 60  
... ... @@ -297,10 +297,10 @@
297 297  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
298 298  
299 299  
300 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %)
312 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
301 301  |=(% style="width: 110px;" %)(((
302 302  **AT Commands**
303 -)))|=(% style="width: 210px;" %)(((
315 +)))|=(% style="width: 190px;" %)(((
304 304  **Description**
305 305  )))|=(% style="width: 190px;" %)(((
306 306  **Example**
... ... @@ -368,8 +368,8 @@
368 368  )))
369 369  )))
370 370  
371 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %)
372 -|=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 190px;" %)**Example**
383 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
384 +|=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
373 373  |AT+CFGDEV|(% style="width:110px" %)(((
374 374  (((
375 375  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
... ... @@ -418,7 +418,7 @@
418 418  
419 419  (% border="1" style="background-color:#4bacc6; color:white; width:499px" %)
420 420  |(% style="width:496px" %)(((
421 -**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
433 +(% style="color:#037691" %)**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
422 422  
423 423  **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
424 424  
... ... @@ -504,15 +504,13 @@
504 504  Final Payload is (% style="color:#4f81bd" %)**PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
505 505  
506 506  
507 -~1. PAYVER: Defined by AT+PAYVER
519 +1. PAYVER: Defined by AT+PAYVER
520 +1. PAYLOAD COUNT: Total how many uplinks of this sampling.
521 +1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
522 +1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
508 508  
509 -2. PAYLOAD COUNT: Total how many uplinks of this sampling.
510 510  
511 -3. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
512 512  
513 -4. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
514 -
515 -
516 516  (% aria-label="image-20220602155039-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602155039-4.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
517 517  
518 518  
... ... @@ -578,26 +578,8 @@
578 578  == 3.4 Uplink Payload ==
579 579  
580 580  
581 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:500px" %)
582 -|=(% scope="row" style="width: 60px;" %)(((
583 -Size(bytes)
584 -)))|(% style="width:80px" %)1|(% style="width:360px" %)(((
585 -Length depends on the return from the commands
586 -)))
587 -|=(% style="width: 90px;" %)(((
588 -Value
589 -)))|(% style="width:114px" %)(((
590 -PAYLOAD_VER
591 -)))|(% style="width:353px" %)(((
592 -If the valid payload is too long and exceed the maximum
591 +(% aria-label="image-20220606110929-1.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220606110929-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
593 593  
594 -support payload length in server, server will show payload not
595 -
596 -provided in the LoRaWAN server.
597 -)))
598 -
599 -(% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
600 -
601 601  (% title="Click and drag to resize" %)​
602 602  
603 603  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
... ... @@ -659,7 +659,7 @@
659 659  
660 660  
661 661  (((
662 -This command is used to configure the RS485 devices; they won't be used during sampling. Max Length of AT+CFGDEV is **40 bytes**.
654 +This command is used to configure the RS485 devices; they won't be used during sampling.
663 663  )))
664 664  
665 665  (((
... ... @@ -1141,10 +1141,15 @@
1141 1141  
1142 1142  (((
1143 1143  Set the Rs485 serial communication parameters:
1136 +
1137 +
1144 1144  )))
1145 1145  
1146 -(((
1147 -(% style="color:#037691" %)**AT Command:**
1140 +* (((
1141 +(% style="color:#037691" %)** AT Command:**
1142 +
1143 +
1144 +
1148 1148  )))
1149 1149  
1150 1150  (((
... ... @@ -1151,7 +1151,7 @@
1151 1151  * Set Baud Rate
1152 1152  )))
1153 1153  
1154 -(% style="color:#4472c4" %)** AT+BAUDR=9600** (%%) ~/~/  Options: (200~~115200)  When using low baud rate or receiving multiple bytes, you need to use AT+CMDDL to increase the receive timeout (the default receive timeout is 400ms), otherwise data will be lost
1151 +(% style="color:#4472c4" %)** AT+BAUDR=9600** (%%) ~/~/  Options: (200~~115200)  When using low baud rate or receiving multiple bytes, you need to use AT+CMDDL to increase the receive timeout (the default receive timeout is 400ms), otherwise data will be lost
1155 1155  
1156 1156  
1157 1157  (((
... ... @@ -1158,7 +1158,7 @@
1158 1158  * Set UART Parity
1159 1159  )))
1160 1160  
1161 -(% style="color:#4472c4" %)** AT+PARITY=0** (%%) ~/~/  Option: 0: no parity, 1: odd parity, 2: even parity
1158 +(% style="color:#4472c4" %)** AT+PARITY=0** (%%) ~/~/  Option: 0: no parity, 1: odd parity, 2: even parity
1162 1162  
1163 1163  
1164 1164  (((
... ... @@ -1165,18 +1165,21 @@
1165 1165  * Set STOPBIT
1166 1166  )))
1167 1167  
1168 -(% style="color:#4472c4" %)** AT+STOPBIT=0** (%%) ~/~/  Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1165 +(% style="color:#4472c4" %)** AT+STOPBIT=0** (%%) ~/~/  Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1169 1169  
1170 1170  
1171 -(((
1172 -(% style="color:#037691" %)**Downlink Payload:**
1168 +
1169 +* (((
1170 +(% style="color:#037691" %)** Downlink Payload:**
1173 1173  )))
1174 1174  
1175 1175  (((
1176 -(% style="color:#4472c4" %)** A7 01 aa bb**:   (%%) Same  AT+BAUDR=hex(aa bb)*100
1174 +(% style="color:#4472c4" %)** A7 01 aa bb**:   (%%) Same  AT+BAUDR=hex(aa bb)*100
1177 1177  )))
1178 1178  
1179 1179  (((
1178 +
1179 +
1180 1180  **Example:**
1181 1181  )))
1182 1182  
... ... @@ -1198,26 +1198,7 @@
1198 1198  
1199 1199  
1200 1200  
1201 -==== (% style="color:blue" %)**Configure Databit (Since Version 1.4.0)**(%%) ====
1202 1202  
1203 -* (((
1204 -(% style="color:#037691" %)** AT Command:**
1205 -)))
1206 -
1207 -**~ AT+DATABIT=7    **~/~/ Set the data bits to 7
1208 -
1209 -**~ AT+DATABIT=8    **~/~/ Set the data bits to 8
1210 -
1211 -* (((
1212 -(% style="color:#037691" %)**Downlink Payload:**
1213 -)))
1214 -
1215 -**~ A7 04 07**: Same as  AT+DATABIT=7
1216 -
1217 -**~ A7 04 08**: Same as  AT+DATABIT=8
1218 -
1219 -
1220 -
1221 1221  ==== (% style="color:blue" %)**Encrypted payload**(%%) ====
1222 1222  
1223 1223  (((
... ... @@ -1293,17 +1293,20 @@
1293 1293  
1294 1294  (% style="color:#4472c4" %)** AT+RPL=5**  (%%) ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100.
1295 1295  
1277 +
1296 1296  Example:**aa xx xx xx xx**         ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent.
1297 1297  
1298 1298  
1299 1299  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]]
1300 1300  
1301 -For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77.
1302 1302  
1303 1303  
1285 +For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77.
1304 1304  
1287 +
1305 1305  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]]
1306 1306  
1290 +
1307 1307  For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned.
1308 1308  
1309 1309  
... ... @@ -1345,7 +1345,7 @@
1345 1345  (% style="color:#037691" %)**Downlink Payload:**
1346 1346  )))
1347 1347  
1348 -(% style="color:#4472c4" %)** A6 aa bb bb               ** (%%) ~/~/ same as AT+RXMODE=aa,bb
1332 +(% style="color:#4472c4" %)** A6 aa bb bb               ** (%%) ~/~/same as AT+RXMODE=aa,bb
1349 1349  
1350 1350  [[image:image-20220824144240-1.png]]
1351 1351  
... ... @@ -1462,8 +1462,8 @@
1462 1462  == 3.7 Buttons ==
1463 1463  
1464 1464  
1465 -(% border="1.5" cellspacing="4" style="background-color:#ffffcc; width:430px" %)
1466 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 380px;" %)**Feature**
1449 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1450 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 361px;" %)**Feature**
1467 1467  |(% style="width:50px" %)**ACT**|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1468 1468  |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1469 1469  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
... ... @@ -1473,7 +1473,7 @@
1473 1473  == 3.8 LEDs ==
1474 1474  
1475 1475  
1476 -(% border="1.5" cellspacing="4" style="background-color:#ffffcc; width:430px" %)
1460 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1477 1477  |=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1478 1478  |**PWR**|Always on if there is power
1479 1479  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.