Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -108,8 +108,6 @@ 108 108 * Automatic RF Sense and CAD with ultra-fast AFC. 109 109 * Packet engine up to 256 bytes with CRC 110 110 111 - 112 - 113 113 == 1.3 Features == 114 114 115 115 ... ... @@ -122,8 +122,6 @@ 122 122 * Support Modbus protocol 123 123 * Support Interrupt uplink (Since hardware version v1.2) 124 124 125 - 126 - 127 127 == 1.4 Applications == 128 128 129 129 ... ... @@ -134,8 +134,6 @@ 134 134 * Smart Cities 135 135 * Smart Factory 136 136 137 - 138 - 139 139 == 1.5 Firmware Change log == 140 140 141 141 ... ... @@ -367,8 +367,6 @@ 367 367 ))) 368 368 ))) 369 369 370 - 371 - 372 372 === 3.3.2 Configure sensors === 373 373 374 374 ... ... @@ -396,8 +396,6 @@ 396 396 ))) 397 397 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 398 398 399 - 400 - 401 401 === 3.3.3 Configure read commands for each sampling === 402 402 403 403 ... ... @@ -521,8 +521,6 @@ 521 521 1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 522 522 1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 523 523 524 - 525 - 526 526 (% aria-label="image-20220602155039-4.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602155039-4.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 527 527 528 528 ... ... @@ -587,9 +587,26 @@ 587 587 588 588 == 3.4 Uplink Payload == 589 589 578 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:800px" %) 579 +|((( 580 +Size(bytes) 581 +)))|1|((( 582 +Length depends on the return from the commands 583 +))) 584 +|((( 585 +Value 586 +)))|((( 587 +PAYLOAD_VER 588 +)))|((( 589 +If the valid payload is too long and exceed the maximum 590 590 591 - (% aria-label="image-20220606110929-1.png image widget" contenteditable="false"role="region"tabindex="-1"%)[[image:image-20220606110929-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png);background:rgba(220,220,220,0.5); display:none"%)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true"height="15"role="presentation"title="Clickanddrag tomove" width="15"]]591 +support payload length in server, server will show payload not 592 592 593 +provided in the LoRaWAN server. 594 +))) 595 + 596 +(% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]] 597 + 593 593 (% title="Click and drag to resize" %) 594 594 595 595 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. ... ... @@ -651,7 +651,7 @@ 651 651 652 652 653 653 ((( 654 -This command is used to configure the RS485 devices; they won't be used during sampling. 659 +This command is used to configure the RS485 devices; they won't be used during sampling. Max Length of AT+CFGDEV is **40 bytes**. 655 655 ))) 656 656 657 657 ((( ... ... @@ -1133,15 +1133,10 @@ 1133 1133 1134 1134 ((( 1135 1135 Set the Rs485 serial communication parameters: 1136 - 1137 - 1138 1138 ))) 1139 1139 1140 -* ((( 1141 -(% style="color:#037691" %)** AT Command:** 1142 - 1143 - 1144 - 1143 +((( 1144 +(% style="color:#037691" %)**AT Command:** 1145 1145 ))) 1146 1146 1147 1147 ((( ... ... @@ -1148,7 +1148,7 @@ 1148 1148 * Set Baud Rate 1149 1149 ))) 1150 1150 1151 -(% style="color:#4472c4" %)** AT+BAUDR=9600** (%%) ~/~/ Options: (200~~115200) When using low baud rate or receiving multiple bytes, you need to use AT+CMDDL to increase the receive timeout (the default receive timeout is 400ms), otherwise data will be lost 1151 +(% style="color:#4472c4" %)** AT+BAUDR=9600** (%%) ~/~/ Options: (200~~115200) When using low baud rate or receiving multiple bytes, you need to use AT+CMDDL to increase the receive timeout (the default receive timeout is 400ms), otherwise data will be lost 1152 1152 1153 1153 1154 1154 ((( ... ... @@ -1155,7 +1155,7 @@ 1155 1155 * Set UART Parity 1156 1156 ))) 1157 1157 1158 -(% style="color:#4472c4" %)** AT+PARITY=0** (%%) ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1158 +(% style="color:#4472c4" %)** AT+PARITY=0** (%%) ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1159 1159 1160 1160 1161 1161 ((( ... ... @@ -1162,21 +1162,18 @@ 1162 1162 * Set STOPBIT 1163 1163 ))) 1164 1164 1165 -(% style="color:#4472c4" %)** AT+STOPBIT=0** (%%) ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1165 +(% style="color:#4472c4" %)** AT+STOPBIT=0** (%%) ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1166 1166 1167 1167 1168 - 1169 -* ((( 1170 -(% style="color:#037691" %)** Downlink Payload:** 1168 +((( 1169 +(% style="color:#037691" %)**Downlink Payload:** 1171 1171 ))) 1172 1172 1173 1173 ((( 1174 -(% style="color:#4472c4" %)** A7 01 aa bb**: (%%) Same AT+BAUDR=hex(aa bb)*100 1173 +(% style="color:#4472c4" %)** A7 01 aa bb**: (%%) Same AT+BAUDR=hex(aa bb)*100 1175 1175 ))) 1176 1176 1177 1177 ((( 1178 - 1179 - 1180 1180 **Example:** 1181 1181 ))) 1182 1182 ... ... @@ -1196,9 +1196,26 @@ 1196 1196 ))) 1197 1197 1198 1198 1196 +==== (% style="color:blue" %)**Configure Databit (Since Version 1.4.1)**(%%) ==== 1199 1199 1198 +* ((( 1199 +(% style="color:#037691" %)** AT Command:** 1200 +))) 1200 1200 1202 +**~ AT+DATABIT=7 **~/~/ Set the data bits to 7 1201 1201 1204 +**~ AT+DATABIT=8 **~/~/Set the data bits to 8 1205 + 1206 +* ((( 1207 +(% style="color:#037691" %)**Downlink Payload:** 1208 +))) 1209 + 1210 +**~ A7 04 07**: Same as AT+DATABIT=7 1211 + 1212 +**~ A7 04 08**: Same as AT+DATABIT=8 1213 + 1214 + 1215 + 1202 1202 ==== (% style="color:blue" %)**Encrypted payload**(%%) ==== 1203 1203 1204 1204 ((( ... ... @@ -1452,8 +1452,6 @@ 1452 1452 |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1453 1453 |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1454 1454 1455 - 1456 - 1457 1457 == 3.8 LEDs == 1458 1458 1459 1459 ... ... @@ -1462,8 +1462,6 @@ 1462 1462 |**PWR**|Always on if there is power 1463 1463 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1464 1464 1465 - 1466 - 1467 1467 = 4. Case Study = 1468 1468 1469 1469 ... ... @@ -1708,8 +1708,6 @@ 1708 1708 * (% style="color:red" %)**RU864**(%%): frequency bands RU864 1709 1709 * (% style="color:red" %)**KZ865**(%%): frequency bands KZ865 1710 1710 1711 - 1712 - 1713 1713 = 9.Packing Info = 1714 1714 1715 1715 ... ... @@ -1726,8 +1726,6 @@ 1726 1726 * Package Size / pcs : 14.5 x 8 x 5 cm 1727 1727 * Weight / pcs : 170g 1728 1728 1729 - 1730 - 1731 1731 = 10. FCC Caution for RS485LN-US915 = 1732 1732 1733 1733