Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -679,7 +679,7 @@ 679 679 (% style="color:#037691" %)**AT Command** 680 680 681 681 ((( 682 -** (% style="color:#4472C4" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**(%%)m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command682 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 683 683 ))) 684 684 ))) 685 685 ... ... @@ -692,7 +692,7 @@ 692 692 ))) 693 693 694 694 ((( 695 -Format: (%%)**(% style="color:#4472C4" %)A8 MM NN XX XX XX XX YY**695 +Format: A8 MM NN XX XX XX XX YY 696 696 ))) 697 697 698 698 ((( ... ... @@ -801,7 +801,7 @@ 801 801 * ((( 802 802 (% style="color:#037691" %)**AT Command:** 803 803 804 -** (% style="color:#4472C4" %)AT+PAYVER: **(%%)Set PAYVER field = 1804 +**AT+PAYVER: **Set PAYVER field = 1 805 805 806 806 807 807 ))) ... ... @@ -810,18 +810,18 @@ 810 810 ))) 811 811 812 812 ((( 813 -** (% style="color:#4472C4" %)0xAE 01**(%%)~-~-> Set PAYVER field = 0x01813 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 814 814 ))) 815 815 816 816 ((( 817 -** (% style="color:#4472C4" %)0xAE 0F**(%%)~-~-> Set PAYVER field = 0x0F817 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 818 818 ))) 819 819 820 820 821 -1) 821 +1)Add the interrupt flag at the highest bit of the Payver byte, that is, Byte7 of the first byte. (Since v1.4.0)[[image:image-20220824145428-2.png||height="168" width="1300"]] 822 822 823 823 824 -2) 824 +2)if the data intercepted by AT+DATACUT or AT+MBFUN is empty, it will display NULL, and the payload will be filled with n FFs. 825 825 826 826 [[image:image-20220824145428-3.png||height="308" width="1200"]] 827 827 ... ... @@ -845,9 +845,9 @@ 845 845 (% style="color:#037691" %)**AT Command:** 846 846 ))) 847 847 848 -** (% style="color:#4472C4" %)AT+COMMANDx: **(%%)Configure RS485 read command to sensor.848 +**AT+COMMANDx: **Configure RS485 read command to sensor. 849 849 850 -** (% style="color:#4472C4" %)AT+DATACUTx: **(%%)Configure how to handle return from RS485 devices.850 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 851 851 852 852 853 853 * ((( ... ... @@ -855,19 +855,19 @@ 855 855 ))) 856 856 857 857 ((( 858 -** (% style="color:#4472C4" %)0xAF**(%%)858 +**0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 859 859 860 860 861 861 ))) 862 862 863 863 ((( 864 -(% style="color:red" %)**Note **864 +(% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 865 865 866 866 867 867 ))) 868 868 869 869 ((( 870 -Format: (%%)**(% style="color:#4472C4" %)AF MM NN LL XX XX XX XX YY**870 +Format: AF MM NN LL XX XX XX XX YY 871 871 ))) 872 872 873 873 ((( ... ... @@ -915,7 +915,7 @@ 915 915 916 916 917 917 ((( 918 -** (% style="color:#4472C4" %)AT+MBFUN**(%%)is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].918 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 919 919 ))) 920 920 921 921 ((( ... ... @@ -967,7 +967,7 @@ 967 967 * ((( 968 968 (% style="color:#037691" %)** AT Command:** 969 969 970 -** (% style="color:#4472C4" %)AT+CMDDLaa=hex(bb cc)*1000**970 +**AT+CMDDLaa=hex(bb cc)*1000** 971 971 ))) 972 972 973 973 ((( ... ... @@ -977,7 +977,7 @@ 977 977 ))) 978 978 979 979 ((( 980 -** (% style="color:#4472C4" %)AT+CMDDL1=1000**(%%)to send the open time to 1000ms980 +**AT+CMDDL1=1000** to send the open time to 1000ms 981 981 ))) 982 982 983 983 ((( ... ... @@ -989,7 +989,7 @@ 989 989 ))) 990 990 991 991 ((( 992 -** (% style="color:#4472C4" %)0x AA aa bb cc**992 +**0x AA aa bb cc** 993 993 ))) 994 994 995 995 ((( ... ... @@ -1021,14 +1021,14 @@ 1021 1021 * ((( 1022 1022 (% style="color:#037691" %)** AT Command:** 1023 1023 1024 -** (% style="color:#4472C4" %)AT+DATAUP=0**1024 +**AT+DATAUP=0** 1025 1025 1026 -** (% style="color:#4472C4" %)AT+DATAUP=1**1026 +**AT+DATAUP=1** 1027 1027 1028 1028 1029 1029 ))) 1030 1030 1031 -** (% style="color:#4472C4" %)0xAD 01 00 00 14**(%%)**~-~->** Same as AT+DATAUP=1,20000 ~/~/(00 00 14 is 20 seconds)1031 +**0xAD 01 00 00 14** **~-~->** Same as AT+DATAUP=1,20000 ~/~/(00 00 14 is 20 seconds) 1032 1032 1033 1033 Each uplink is sent to the server at 20-second intervals when segmented. 1034 1034 ... ... @@ -1037,9 +1037,9 @@ 1037 1037 (% style="color:#037691" %)** Downlink Payload:** 1038 1038 ))) 1039 1039 1040 -** (% style="color:#4472C4" %)0xAD 00**(%%)**~-~->** Same as AT+DATAUP=01040 +**0xAD 00** **~-~->** Same as AT+DATAUP=0 1041 1041 1042 -** (% style="color:#4472C4" %)0xAD 01**(%%)**~-~->** Same as AT+DATAUP=1 ~/~/Each uplink is sent to the server one after the other as it is segmented.1042 +**0xAD 01** **~-~->** Same as AT+DATAUP=1 ~/~/Each uplink is sent to the server one after the other as it is segmented. 1043 1043 1044 1044 1045 1045 * ((( ... ... @@ -1046,7 +1046,7 @@ 1046 1046 (% style="color:#037691" %)** AT Command:** 1047 1047 ))) 1048 1048 1049 -** (% style="color:#4472C4" %)AT+DATAUP=1,Timeout**1049 +**AT+DATAUP=1,Timeout** 1050 1050 1051 1051 1052 1052 * ((( ... ... @@ -1053,12 +1053,10 @@ 1053 1053 (% style="color:#037691" %)** Downlink Payload:** 1054 1054 ))) 1055 1055 1056 -** (% style="color:#4472C4" %)0xAD 01 00 00 14**(%%)**~-~->** Same as AT+DATAUP=1,20000 ~/~/(00 00 14 is 20 seconds)1056 +**0xAD 01 00 00 14** **~-~->** Same as AT+DATAUP=1,20000 ~/~/(00 00 14 is 20 seconds) 1057 1057 1058 1058 Each uplink is sent to the server at 20-second intervals when segmented. 1059 1059 1060 - 1061 - 1062 1062 ==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ==== 1063 1063 1064 1064 ... ... @@ -1083,7 +1083,7 @@ 1083 1083 ))) 1084 1084 1085 1085 ((( 1086 -** (% style="color:#4472C4" %)0x08 FF**(%%), RS485-LN will immediately send an uplink.1084 +**0x08 FF**, RS485-LN will immediately send an uplink. 1087 1087 ))) 1088 1088 1089 1089 ... ... @@ -1103,7 +1103,7 @@ 1103 1103 ))) 1104 1104 1105 1105 ((( 1106 -** (% style="color:#4472C4" %)AT+CMDEAR=mm,nn**(%%)mm: start position of erase ,nn: stop position of erase1104 +**AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 1107 1107 ))) 1108 1108 1109 1109 ((( ... ... @@ -1130,7 +1130,7 @@ 1130 1130 ))) 1131 1131 1132 1132 ((( 1133 -** (% style="color:#4472C4" %)0x09 aa bb**(%%)same as AT+CMDEAR=aa,bb1131 +**0x09 aa bb** same as AT+CMDEAR=aa,bb 1134 1134 ))) 1135 1135 1136 1136 ... ... @@ -1153,7 +1153,7 @@ 1153 1153 * Set Baud Rate 1154 1154 ))) 1155 1155 1156 -** (% style="color:#4472C4" %)AT+BAUDR=9600**(%%)~/~/ Options: (200~~115200) When using low baud rate or receiving multiple bytes, you need to use AT+CMDDL to increase the receive timeout (the default receive timeout is 400ms), otherwise data will be lost1154 +**AT+BAUDR=9600** ~/~/ Options: (200~~115200) When using low baud rate or receiving multiple bytes, you need to use AT+CMDDL to increase the receive timeout (the default receive timeout is 400ms), otherwise data will be lost 1157 1157 1158 1158 1159 1159 ((( ... ... @@ -1160,7 +1160,7 @@ 1160 1160 * Set UART Parity 1161 1161 ))) 1162 1162 1163 -** (% style="color:#4472C4" %)AT+PARITY=0**(%%)~/~/ Option: 0: no parity, 1: odd parity, 2: even parity1161 +**AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1164 1164 1165 1165 1166 1166 (((