31 31  = 1.Introduction =
32 32  
33 -
34 34  == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
35 35  
36 36  (((
... ... @@ -82,15 +82,11 @@
82 82  ** Idle: 32mA@12v
83 83  ** 20dB Transmit: 65mA@12v
84 84  
85 -
86 -
87 87  (% style="color:#037691" %)**Interface for Model:**
88 88  
89 89  * RS485
90 90  * Power Input 7~~ 24V DC. 
91 91  
92 -
93 -
94 94  (% style="color:#037691" %)**LoRa Spec:**
95 95  
96 96  * Frequency Range:
... ... @@ -112,9 +112,6 @@
112 112  * Automatic RF Sense and CAD with ultra-fast AFC.
113 113  * Packet engine up to 256 bytes with CRC
114 114  
115 -
116 -
117 -
118 118  == 1.3 Features ==
119 119  
120 120  
... ... @@ -127,9 +127,6 @@
127 127  * Support Modbus protocol
128 128  * Support Interrupt uplink (Since hardware version v1.2)
129 129  
130 -
131 -
132 -
133 133  == 1.4 Applications ==
134 134  
135 135  
... ... @@ -140,9 +140,6 @@
140 140  * Smart Cities
141 141  * Smart Factory
142 142  
143 -
144 -
145 -
146 146  == 1.5 Firmware Change log ==
147 147  
148 148  
... ... @@ -189,7 +189,6 @@
189 189  
190 190  = 3. Operation Mode =
191 191  
192 -
193 193  == 3.1 How it works? ==
194 194  
195 195  
... ... @@ -1257,6 +1257,7 @@
1257 1257  
1258 1258  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]]
1259 1259  
1245 +(% class="wikigeneratedid" %)
1260 1260  ==== ====
1261 1261  
1262 1262  ==== (% style="color:blue" %)** Monitor RS485 communication of other devices**(%%) ====
... ... @@ -1268,7 +1268,7 @@
1268 1268  
1269 1269  **~ ​AT+RXMODE=1,10**  ~/~/ When the RS485-LN receives more than 10 bytes from the RS485, it immediately sends the uplink of the received data.
1270 1270  
1271 -**~ ​AT+RXMODE=2,500    ** ~/~/RS485-LN uploads data as uplink from the first byte received by RS485 to the data received within 500ms after that.
1257 +**~ ​AT+RXMODE=2,500 ** ~/~/RS485-LN uploads data as uplink from the first byte received by RS485 to the data received within 500ms after that.
1272 1272  
1273 1273   **AT+RXMODE=0,0  ** ~/~/Disable this mode (default)
1274 1274  
... ... @@ -1277,7 +1277,7 @@
1277 1277  (% style="color:#037691" %)**Downlink Payload:**
1278 1278  )))
1279 1279  
1280 -**A6 aa bb bb                   ** ~/~/same as AT+RXMODE=aa,bb
1266 +**A6 aa bb bb  ** ~/~/same as AT+RXMODE=aa,bb
1281 1281  
1282 1282  [[image:image-20220824144240-1.png]]
1283 1283  
... ... @@ -1532,7 +1532,7 @@
1532 1532  )))
1533 1533  
1534 1534  (((
1535 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACP33wo_ZQLsxW2MJ70oUoba/RS485-LN/Firmware?dl=0&subfolder_nav_tracking=1]].
1521 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Firmware/]].
1536 1536  )))
1537 1537  
1538 1538  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0