Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -30,6 +30,7 @@ 30 30 31 31 = 1.Introduction = 32 32 33 + 33 33 == 1.1 What is RS485-LN RS485 to LoRaWAN Converter == 34 34 35 35 ((( ... ... @@ -73,7 +73,7 @@ 73 73 == 1.2 Specifications == 74 74 75 75 76 -**Hardware System:** 77 +(% style="color:#037691" %)**Hardware System:** 77 77 78 78 * STM32L072CZT6 MCU 79 79 * SX1276/78 Wireless Chip ... ... @@ -81,13 +81,17 @@ 81 81 ** Idle: 32mA@12v 82 82 ** 20dB Transmit: 65mA@12v 83 83 84 -**Interface for Model:** 85 85 86 + 87 +(% style="color:#037691" %)**Interface for Model:** 88 + 86 86 * RS485 87 87 * Power Input 7~~ 24V DC. 88 88 89 -**LoRa Spec:** 90 90 93 + 94 +(% style="color:#037691" %)**LoRa Spec:** 95 + 91 91 * Frequency Range: 92 92 ** Band 1 (HF): 862 ~~ 1020 Mhz 93 93 ** Band 2 (LF): 410 ~~ 528 Mhz ... ... @@ -108,11 +108,13 @@ 108 108 * Packet engine up to 256 bytes with CRC 109 109 110 110 116 + 117 + 111 111 == 1.3 Features == 112 112 113 113 114 114 * LoRaWAN Class A & Class C protocol (default Class C) 115 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864 122 +* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864/MA869 116 116 * AT Commands to change parameters 117 117 * Remote configure parameters via LoRa Downlink 118 118 * Firmware upgradable via program port ... ... @@ -121,6 +121,8 @@ 121 121 * Support Interrupt uplink (Since hardware version v1.2) 122 122 123 123 131 + 132 + 124 124 == 1.4 Applications == 125 125 126 126 ... ... @@ -132,6 +132,8 @@ 132 132 * Smart Factory 133 133 134 134 144 + 145 + 135 135 == 1.5 Firmware Change log == 136 136 137 137 ... ... @@ -178,6 +178,7 @@ 178 178 179 179 = 3. Operation Mode = 180 180 192 + 181 181 == 3.1 How it works? == 182 182 183 183 ... ... @@ -212,6 +212,8 @@ 212 212 213 213 ((( 214 214 The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3: 227 + 228 + 215 215 ))) 216 216 217 217 ((( ... ... @@ -346,7 +346,6 @@ 346 346 ))) 347 347 ))) 348 348 349 - 350 350 === 3.3.2 Configure sensors === 351 351 352 352 ... ... @@ -374,7 +374,6 @@ 374 374 ))) 375 375 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 376 376 377 - 378 378 === 3.3.3 Configure read commands for each sampling === 379 379 380 380 ... ... @@ -418,7 +418,7 @@ 418 418 In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 419 419 420 420 421 -(% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 45bytes.433 +(% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes. 422 422 423 423 (% border="1" style="background-color:#4bacc6; color:white; width:510px" %) 424 424 |(% style="width:510px" %)((( ... ... @@ -436,11 +436,13 @@ 436 436 (% aria-label="image-20220602153621-1.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-1.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 437 437 438 438 451 + 439 439 * (% style="color:#037691" %)**Grab a section** 440 440 441 441 (% aria-label="image-20220602153621-2.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-2.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 442 442 443 443 457 + 444 444 * (% style="color:#037691" %)**Grab different sections** 445 445 446 446 (% aria-label="image-20220602153621-3.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602153621-3.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) ... ... @@ -520,7 +520,22 @@ 520 520 521 521 ~* For all other bands: max 51 bytes for each uplink. 522 522 537 +(% style="color:red" %)*** When AT+DATAUP=1, the maximum number of segments is 15, and the maximum total number of bytes is 1500;** 523 523 539 +(% style="color:red" %)** When AT+DATAUP=1 and AT+ADR=0, the maximum number of bytes of each payload is determined by the DR value. (Since v1.4.0)** 540 + 541 + 542 +(% style="color:#4f81bd" %)**If the data is empty, return to the display(Since v1.4.0)** 543 + 544 +1)When AT+MOD=1, if the data intercepted by AT+DATACUT or AT+MBFUN is empty, it will display NULL, and the payload will be filled with n FFs. 545 + 546 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/test/WebHome/image-20220824114359-3.png?width=1106&height=297&rev=1.1||alt="image-20220824114359-3.png" height="297" width="1106"]] 547 + 548 +2)When AT+MOD=2, if the data intercepted by AT+DATACUT or AT+MBFUN is empty, it will display NULL, and the payload will be filled with n 00s. 549 + 550 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/test/WebHome/image-20220824114330-2.png?rev=1.1||alt="image-20220824114330-2.png"]] 551 + 552 + 524 524 Below are the uplink payloads: 525 525 526 526 (% aria-label="1654157178836-407.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157178836-407.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) ... ... @@ -610,6 +610,7 @@ 610 610 611 611 ==== (% style="color:blue" %)**RS485 Debug Command**(%%) ==== 612 612 642 + 613 613 ((( 614 614 This command is used to configure the RS485 devices; they won't be used during sampling. 615 615 ))) ... ... @@ -666,7 +666,7 @@ 666 666 ((( 667 667 668 668 669 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 699 +(% style="color:blue" %)**Example 1:** (%%) ~-~-> Configure without ask for uplink (YY=0) 670 670 ))) 671 671 672 672 ((( ... ... @@ -704,7 +704,7 @@ 704 704 ))) 705 705 706 706 ((( 707 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 737 +(% style="color:blue" %)**Example 2:** (%%) ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 708 708 ))) 709 709 710 710 ((( ... ... @@ -732,6 +732,7 @@ 732 732 733 733 ==== (% style="color:blue" %)**Set Payload version**(%%) ==== 734 734 765 + 735 735 ((( 736 736 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 737 737 ))) ... ... @@ -756,10 +756,17 @@ 756 756 ))) 757 757 758 758 790 +1)Add the interrupt flag at the highest bit of the Payver byte, that is, Byte7 of the first byte. (Since v1.4.0)[[image:image-20220824145428-2.png||height="168" width="1300"]] 759 759 760 760 793 +2)if the data intercepted by AT+DATACUT or AT+MBFUN is empty, it will display NULL, and the payload will be filled with n FFs. 794 + 795 +[[image:image-20220824145428-3.png||height="308" width="1200"]] 796 + 797 + 761 761 ==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ==== 762 762 800 + 763 763 ((( 764 764 AT+COMMANDx or AT+DATACUTx 765 765 ))) ... ... @@ -787,10 +787,14 @@ 787 787 788 788 ((( 789 789 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 828 + 829 + 790 790 ))) 791 791 792 792 ((( 793 793 (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 834 + 835 + 794 794 ))) 795 795 796 796 ((( ... ... @@ -840,6 +840,7 @@ 840 840 841 841 ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ==== 842 842 885 + 843 843 ((( 844 844 **AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 845 845 ))) ... ... @@ -881,6 +881,7 @@ 881 881 882 882 ==== (% style="color:blue" %)**RS485 command timeout**(%%) ==== 883 883 927 + 884 884 ((( 885 885 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. 886 886 ))) ... ... @@ -930,10 +930,9 @@ 930 930 ))) 931 931 932 932 933 - 934 - 935 935 ==== (% style="color:blue" %)**Uplink payload mode**(%%) ==== 936 936 979 + 937 937 ((( 938 938 Define to use one uplink or multiple uplinks for the sampling. 939 939 ))) ... ... @@ -946,30 +946,46 @@ 946 946 947 947 * ((( 948 948 (% style="color:#037691" %)** AT Command:** 949 -))) 950 950 951 951 **AT+DATAUP=0** 952 952 953 953 **AT+DATAUP=1** 954 954 997 + 998 +))) 955 955 1000 +**0xAD 01 00 00 14** **~-~->** Same as AT+DATAUP=1,20000 ~/~/(00 00 14 is 20 seconds) 1001 + 1002 +Each uplink is sent to the server at 20-second intervals when segmented. 1003 + 1004 + 956 956 * ((( 957 957 (% style="color:#037691" %)** Downlink Payload:** 958 958 ))) 959 959 960 -((( 961 -**0xAD 00** **~-~->** Same as AT+DATAUP=0 962 -))) 1009 +**0xAD 00** **~-~->** Same as AT+DATAUP=0 963 963 964 -((( 965 -**0xAD 01** **~-~->** Same as AT+DATAUP=1 1011 +**0xAD 01** **~-~->** Same as AT+DATAUP=1 ~/~/Each uplink is sent to the server one after the other as it is segmented. 1012 + 1013 + 1014 +* ((( 1015 +(% style="color:#037691" %)** AT Command:** 966 966 ))) 967 967 1018 +**AT+DATAUP=1,Timeout** 968 968 969 969 1021 +* ((( 1022 +(% style="color:#037691" %)** Downlink Payload:** 1023 +))) 970 970 1025 +**0xAD 01 00 00 14** **~-~->** Same as AT+DATAUP=1,20000 ~/~/(00 00 14 is 20 seconds) 1026 + 1027 +Each uplink is sent to the server at 20-second intervals when segmented. 1028 + 971 971 ==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ==== 972 972 1031 + 973 973 ((( 974 974 Ask device to send an uplink immediately. 975 975 ))) ... ... @@ -999,6 +999,7 @@ 999 999 1000 1000 ==== (% style="color:blue" %)**Clear RS485 Command**(%%) ==== 1001 1001 1061 + 1002 1002 ((( 1003 1003 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1004 1004 ... ... @@ -1045,8 +1045,11 @@ 1045 1045 1046 1046 ==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ==== 1047 1047 1108 + 1048 1048 ((( 1049 1049 Set the Rs485 serial communication parameters: 1111 + 1112 + 1050 1050 ))) 1051 1051 1052 1052 * ((( ... ... @@ -1054,12 +1054,10 @@ 1054 1054 ))) 1055 1055 1056 1056 ((( 1057 - 1058 - 1059 1059 * Set Baud Rate 1060 1060 ))) 1061 1061 1062 -**AT+BAUDR=9600** ~/~/ Options: ( 1200,2400,4800,14400,19200,115200)1123 +**AT+BAUDR=9600** ~/~/ Options: (200~~115200) When using low baud rate or receiving multiple bytes, you need to use AT+CMDDL to increase the receive timeout (the default receive timeout is 400ms), otherwise data will be lost 1063 1063 1064 1064 1065 1065 ((( ... ... @@ -1105,8 +1105,123 @@ 1105 1105 ))) 1106 1106 1107 1107 1169 +==== (% style="color:blue" %)**Encrypted payload**(%%) ==== 1108 1108 1171 +((( 1172 + 1173 +))) 1109 1109 1175 +* ((( 1176 +(% style="color:#037691" %)** AT Command:** 1177 +))) 1178 + 1179 +**AT+DECRYPT=1 **~/~/ The payload is uploaded without encryption 1180 + 1181 +**AT+DECRYPT=0 **~/~/Encrypt when uploading payload (default) 1182 + 1183 + 1184 +==== (% style="color:blue" %)**Get sensor value**(%%) ==== 1185 + 1186 + 1187 +* ((( 1188 +(% style="color:#037691" %)** AT Command:** 1189 +))) 1190 + 1191 +**AT+GETSENSORVALUE=0 **~/~/ The serial port gets the reading of the current sensor 1192 + 1193 +**AT+GETSENSORVALUE=1 **~/~/The serial port gets the current sensor reading and uploads it. 1194 + 1195 + 1196 +==== (% style="color:blue" %)**Resets the downlink packet count**(%%) ==== 1197 + 1198 + 1199 +* ((( 1200 +(% style="color:#037691" %)** AT Command:** 1201 +))) 1202 + 1203 +**AT+DISFCNTCHECK=0 **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1204 + 1205 +**AT+DISFCNTCHECK=1 **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1206 + 1207 + 1208 +==== (% style="color:blue" %)**When the limit bytes are exceeded, upload in batches**(%%) ==== 1209 + 1210 + 1211 +* ((( 1212 +(% style="color:#037691" %)** AT Command:** 1213 +))) 1214 + 1215 + **AT+DISMACANS=0** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1216 + 1217 + **AT+DISMACANS=1** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1218 + 1219 + 1220 +* ((( 1221 +(% style="color:#037691" %)** Downlink Payload:** 1222 +))) 1223 + 1224 +**0x21 00 01 ** ~/~/ Set the DISMACANS=1 1225 + 1226 + 1227 +==== (% style="color:blue" %)** Copy downlink to uplink **(%%) ==== 1228 + 1229 + 1230 +* ((( 1231 +(% style="color:#037691" %)** AT Command:** 1232 +))) 1233 + 1234 +**AT+RPL=5** ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100. 1235 + 1236 +Example:**aa xx xx xx xx** ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent. 1237 + 1238 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]] 1239 + 1240 +For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77. 1241 + 1242 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]] 1243 + 1244 +For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned. 1245 + 1246 + 1247 +==== (% style="color:blue" %)**Query version number and frequency band 、TDC**(%%) ==== 1248 + 1249 + 1250 +* ((( 1251 +(% style="color:#037691" %)**Downlink Payload:** 1252 + 1253 +**26 01 ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time. 1254 +))) 1255 + 1256 +Example: 1257 + 1258 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1259 + 1260 +==== ==== 1261 + 1262 +==== (% style="color:blue" %)** Monitor RS485 communication of other devices**(%%) ==== 1263 + 1264 + 1265 +* ((( 1266 +(% style="color:#037691" %)** AT Command:** 1267 +))) 1268 + 1269 +**~ AT+RXMODE=1,10** ~/~/ When the RS485-LN receives more than 10 bytes from the RS485, it immediately sends the uplink of the received data. 1270 + 1271 +**~ AT+RXMODE=2,500 ** ~/~/RS485-LN uploads data as uplink from the first byte received by RS485 to the data received within 500ms after that. 1272 + 1273 + **AT+RXMODE=0,0 ** ~/~/Disable this mode (default) 1274 + 1275 + 1276 +* ((( 1277 +(% style="color:#037691" %)**Downlink Payload:** 1278 +))) 1279 + 1280 +**A6 aa bb bb ** ~/~/same as AT+RXMODE=aa,bb 1281 + 1282 +[[image:image-20220824144240-1.png]] 1283 + 1284 + 1285 + 1110 1110 == 3.6 Listening mode for RS485 network == 1111 1111 1112 1112 ... ... @@ -1218,7 +1218,6 @@ 1218 1218 |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1219 1219 |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1220 1220 1221 - 1222 1222 == 3.8 LEDs == 1223 1223 1224 1224 ... ... @@ -1227,7 +1227,6 @@ 1227 1227 |**PWR**|Always on if there is power 1228 1228 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1229 1229 1230 - 1231 1231 = 4. Case Study = 1232 1232 1233 1233 ... ... @@ -1237,6 +1237,7 @@ 1237 1237 1238 1238 = 5. Use AT Command = 1239 1239 1414 + 1240 1240 == 5.1 Access AT Command == 1241 1241 1242 1242 ... ... @@ -1316,6 +1316,8 @@ 1316 1316 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1317 1317 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1318 1318 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1494 + 1495 + 1319 1319 ))) 1320 1320 1321 1321 (% aria-label="1654162478620-421.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162478620-421.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) ... ... @@ -1324,6 +1324,7 @@ 1324 1324 1325 1325 = 6. FAQ = 1326 1326 1504 + 1327 1327 == 6.1 How to upgrade the image? == 1328 1328 1329 1329 ... ... @@ -1354,7 +1354,7 @@ 1354 1354 ))) 1355 1355 1356 1356 ((( 1357 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dr agino.com/downloads/index.php?dir=RS485-LN/Firmware/]].1535 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACP33wo_ZQLsxW2MJ70oUoba/RS485-LN/Firmware?dl=0&subfolder_nav_tracking=1]]. 1358 1358 ))) 1359 1359 1360 1360 ((( ... ... @@ -1457,7 +1457,6 @@ 1457 1457 * (% style="color:red" %)**RU864**(%%): frequency bands RU864 1458 1458 * (% style="color:red" %)**KZ865**(%%): frequency bands KZ865 1459 1459 1460 - 1461 1461 = 9.Packing Info = 1462 1462 1463 1463 ... ... @@ -1474,7 +1474,6 @@ 1474 1474 * Package Size / pcs : 14.5 x 8 x 5 cm 1475 1475 * Weight / pcs : 170g 1476 1476 1477 - 1478 1478 = 10. FCC Caution for RS485LN-US915 = 1479 1479 1480 1480 ... ... @@ -1495,7 +1495,7 @@ 1495 1495 ))) 1496 1496 1497 1497 ((( 1498 -**Note: **This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1674 +(% style="color:red" %)**Note: **(%%)This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1499 1499 ))) 1500 1500 1501 1501 ((( ... ... @@ -1536,4 +1536,7 @@ 1536 1536 ))) 1537 1537 * ((( 1538 1538 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]. 1715 + 1716 + 1717 + 1539 1539 )))
- image-20220824144240-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +110.9 KB - Content
- image-20220824145428-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.6 KB - Content
- image-20220824145428-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.7 KB - Content