From version < 68.2 >
edited by Xiaoling
on 2022/08/08 09:53
To version < 67.1 >
edited by Bei Jinggeng
on 2022/07/08 16:50
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -12,6 +12,11 @@
12 12  
13 13  
14 14  
15 +
16 +
17 +
18 +
19 +
15 15  **Table of Contents:**
16 16  
17 17  {{toc/}}
... ... @@ -69,7 +69,6 @@
69 69  (% aria-label="1653267211009-519.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653267211009-519.png||data-widget="image" height="419" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
70 70  
71 71  
72 -
73 73  == 1.2 Specifications ==
74 74  
75 75  
... ... @@ -108,10 +108,8 @@
108 108  * Packet engine up to 256 bytes with CRC
109 109  
110 110  
111 -
112 112  == 1.3 Features ==
113 113  
114 -
115 115  * LoRaWAN Class A & Class C protocol (default Class C)
116 116  * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
117 117  * AT Commands to change parameters
... ... @@ -122,10 +122,8 @@
122 122  * Support Interrupt uplink (Since hardware version v1.2)
123 123  
124 124  
125 -
126 126  == 1.4 Applications ==
127 127  
128 -
129 129  * Smart Buildings & Home Automation
130 130  * Logistics and Supply Chain Management
131 131  * Smart Metering
... ... @@ -134,17 +134,13 @@
134 134  * Smart Factory
135 135  
136 136  
137 -
138 138  == 1.5 Firmware Change log ==
139 139  
140 -
141 141  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
142 142  
143 143  
144 -
145 145  == 1.6 Hardware Change log ==
146 146  
147 -
148 148  (((
149 149  (((
150 150  (((
... ... @@ -155,7 +155,6 @@
155 155  v1.0: Release
156 156  )))
157 157  
158 -
159 159  
160 160  )))
161 161  )))
... ... @@ -162,7 +162,6 @@
162 162  
163 163  = 2. Power ON Device =
164 164  
165 -
166 166  (((
167 167  The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
168 168  
... ... @@ -175,7 +175,6 @@
175 175  
176 176  (% aria-label="1653268091319-405.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268091319-405.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
177 177  
178 -
179 179  
180 180  )))
181 181  
... ... @@ -183,19 +183,16 @@
183 183  
184 184  == 3.1 How it works? ==
185 185  
186 -
187 187  (((
188 188  (((
189 189  The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
190 190  )))
191 191  
192 -
193 193  
194 194  )))
195 195  
196 196  == 3.2 Example to join LoRaWAN network ==
197 197  
198 -
199 199  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
200 200  
201 201  (% aria-label="1653268155545-638.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268155545-638.png||data-widget="image" height="334" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -265,10 +265,8 @@
265 265  (% aria-label="1652953568895-172.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953568895-172.png||data-widget="image" height="232" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
266 266  
267 267  
268 -
269 269  == 3.3 Configure Commands to read data ==
270 270  
271 -
272 272  (((
273 273  (((
274 274  (((
... ... @@ -278,17 +278,15 @@
278 278  
279 279  (((
280 280  (((
281 -(% style="color:red" %)**Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1**
269 +(% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
282 282  )))
283 283  
284 -
285 285  
286 286  )))
287 287  )))
288 288  
289 -=== 3.3.1 Configure UART settings for RS485 or TTL communication ===
276 +=== 3.3.1 onfigure UART settings for RS485 or TTL communication ===
290 290  
291 -
292 292  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
293 293  
294 294  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
... ... @@ -350,16 +350,11 @@
350 350  )))
351 351  
352 352  
353 -
354 -
355 355  === 3.3.2 Configure sensors ===
356 356  
357 -
358 358  (((
359 359  (((
360 -Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling.
361 -
362 -
343 +Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won’t run during each sampling.
363 363  )))
364 364  )))
365 365  
... ... @@ -380,11 +380,8 @@
380 380  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
381 381  
382 382  
383 -
384 -
385 385  === 3.3.3 Configure read commands for each sampling ===
386 386  
387 -
388 388  (((
389 389  During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload.
390 390  
... ... @@ -458,7 +458,6 @@
458 458  
459 459  === 3.3.4 Compose the uplink payload ===
460 460  
461 -
462 462  (((
463 463  Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
464 464  
... ... @@ -517,7 +517,7 @@
517 517  DATA3=the rest of Valid value of RETURN10= **30**
518 518  
519 519  
520 -(% style="color:red" %)**Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:**
497 +(% style="color:red" %)Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:
521 521  
522 522   ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink.
523 523  
... ... @@ -536,7 +536,6 @@
536 536  
537 537  === 3.3.5 Uplink on demand ===
538 538  
539 -
540 540  Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command.
541 541  
542 542  Downlink control command:
... ... @@ -549,7 +549,6 @@
549 549  
550 550  === 3.3.6 Uplink on Interrupt ===
551 551  
552 -
553 553  RS485-LN support external Interrupt uplink since hardware v1.2 release.
554 554  
555 555  (% aria-label="1654157342174-798.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157342174-798.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -557,7 +557,6 @@
557 557  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
558 558  
559 559  
560 -
561 561  == 3.4 Uplink Payload ==
562 562  
563 563  
... ... @@ -566,10 +566,8 @@
566 566  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
567 567  
568 568  
569 -
570 570  == 3.5 Configure RS485-LN via AT or Downlink ==
571 571  
572 -
573 573  (((
574 574  User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
575 575  )))
... ... @@ -591,17 +591,13 @@
591 591  )))
592 592  
593 593  
594 -
595 595  === 3.5.1 Common Commands ===
596 596  
597 -
598 598  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
599 599  
600 600  
601 -
602 602  === 3.5.2 Sensor related commands ===
603 603  
604 -
605 605  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
606 606  
607 607  (% aria-label="image-20220602163333-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602163333-5.png||data-widget="image" height="263" width="1160"]](% title="Click and drag to resize" %)​
... ... @@ -1116,7 +1116,6 @@
1116 1116  
1117 1117  == 3.6 Listening mode for RS485 network ==
1118 1118  
1119 -
1120 1120  (((
1121 1121  This feature support since firmware v1.4
1122 1122  )))
... ... @@ -1123,8 +1123,6 @@
1123 1123  
1124 1124  (((
1125 1125  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1126 -
1127 -
1128 1128  )))
1129 1129  
1130 1130  (% aria-label="image-20220602171200-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602171200-8.png||data-widget="image" height="567" width="1007"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -1210,12 +1210,11 @@
1210 1210  
1211 1211  (((
1212 1212  (((
1213 -(% style="color:red" %)**Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.**
1178 +(% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1214 1214  )))
1215 1215  )))
1216 1216  
1217 1217  
1218 -
1219 1219  == 3.7 Buttons ==
1220 1220  
1221 1221  
... ... @@ -1226,8 +1226,6 @@
1226 1226  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1227 1227  
1228 1228  
1229 -
1230 -
1231 1231  == 3.8 LEDs ==
1232 1232  
1233 1233  
... ... @@ -1237,20 +1237,15 @@
1237 1237  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1238 1238  
1239 1239  
1240 -
1241 -
1242 1242  = 4. Case Study =
1243 1243  
1244 -
1245 1245  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1246 1246  
1247 1247  
1248 -
1249 1249  = 5. Use AT Command =
1250 1250  
1251 1251  == 5.1 Access AT Command ==
1252 1252  
1253 -
1254 1254  (((
1255 1255  RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below.
1256 1256  )))
... ... @@ -1276,7 +1276,6 @@
1276 1276  
1277 1277  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1278 1278  
1279 -
1280 1280  If device has not joined network yet:
1281 1281  
1282 1282  * (% style="color:#037691" %)**AT+FDR**
... ... @@ -1295,7 +1295,6 @@
1295 1295  )))
1296 1296  
1297 1297  
1298 -
1299 1299  === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1300 1300  
1301 1301  
... ... @@ -1332,12 +1332,10 @@
1332 1332  (% aria-label="1654162478620-421.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162478620-421.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1333 1333  
1334 1334  
1335 -
1336 1336  = 6. FAQ =
1337 1337  
1338 1338  == 6.1 How to upgrade the image? ==
1339 1339  
1340 -
1341 1341  (((
1342 1342  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1343 1343  )))
... ... @@ -1356,16 +1356,14 @@
1356 1356  Below shows the hardware connection for how to upload an image to RS485-LN:
1357 1357  )))
1358 1358  
1359 -(% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
1312 +(% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1360 1360  
1361 -(% title="Click and drag to resize" %)​
1362 -
1363 1363  (((
1364 1364  (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1365 1365  )))
1366 1366  
1367 1367  (((
1368 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Firmware/]].
1319 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1369 1369  )))
1370 1370  
1371 1371  (((
... ... @@ -1390,69 +1390,52 @@
1390 1390  (% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1391 1391  
1392 1392  
1393 -(% style="color:red" %)**Notice**: **In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:**
1344 +(% style="color:red" %)**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1394 1394  
1395 1395  (% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1396 1396  
1397 1397  
1398 -
1399 1399  == 6.2 How to change the LoRa Frequency Bands/Region? ==
1400 1400  
1401 -
1402 1402  User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1403 1403  
1404 1404  
1405 -
1406 1406  == 6.3 How many RS485-Slave can RS485-LN connects? ==
1407 1407  
1408 -
1409 1409  The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1410 1410  
1411 1411  
1412 -
1413 1413  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
1414 1414  
1415 -
1416 1416  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1417 1417  
1418 1418  Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1419 1419  
1420 1420  
1421 -
1422 1422  == 6.5 Can i use point to point communication for RS485-LN? ==
1423 1423  
1424 -
1425 1425  Yes, please refer [[Point to Point Communication for RS485-LN>>Point to Point Communication for RS485-LN]].
1426 1426  
1427 1427  
1428 -
1429 1429  == 6.6 How to Use RS485-LN  to connect to RS232 devices? ==
1430 1430  
1431 -
1432 1432  [[Use RS485-BL or RS485-LN to connect to RS232 devices. - DRAGINO>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/RS485%20to%20RS232/]]
1433 1433  
1434 1434  
1435 -
1436 1436  = 7. Trouble Shooting =
1437 1437  
1438 -
1439 1439  == 7.1 Downlink doesn't work, how to solve it? ==
1440 1440  
1441 -
1442 1442  Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1443 1443  
1444 1444  
1445 -
1446 1446  == 7.2 Why I can't join TTN V3 in US915 /AU915 bands? ==
1447 1447  
1448 -
1449 1449  It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1450 1450  
1451 1451  
1452 -
1453 1453  = 8. Order Info =
1454 1454  
1455 -
1456 1456  (% style="color:blue" %)**Part Number: RS485-LN-XXX**
1457 1457  
1458 1458  (% style="color:blue" %)**XXX:**
... ... @@ -1469,7 +1469,6 @@
1469 1469  * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1470 1470  
1471 1471  
1472 -
1473 1473  = 9.Packing Info =
1474 1474  
1475 1475  
... ... @@ -1487,10 +1487,8 @@
1487 1487  * Weight / pcs : 170g
1488 1488  
1489 1489  
1490 -
1491 1491  = 10. FCC Caution for RS485LN-US915 =
1492 1492  
1493 -
1494 1494  (((
1495 1495  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1496 1496  )))
... ... @@ -1543,7 +1543,6 @@
1543 1543  
1544 1544  = 11. Support =
1545 1545  
1546 -
1547 1547  * (((
1548 1548  Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1549 1549  )))
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0