From version < 64.1 >
edited by Edwin Chen
on 2022/07/03 07:50
To version < 68.4 >
edited by Xiaoling
on 2022/08/18 14:30
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -12,11 +12,6 @@
12 12  
13 13  
14 14  
15 -
16 -
17 -
18 -
19 -
20 20  **Table of Contents:**
21 21  
22 22  {{toc/}}
... ... @@ -74,6 +74,7 @@
74 74  (% aria-label="1653267211009-519.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653267211009-519.png||data-widget="image" height="419" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
75 75  
76 76  
72 +
77 77  == 1.2 Specifications ==
78 78  
79 79  
... ... @@ -111,8 +111,10 @@
111 111  * Automatic RF Sense and CAD with ultra-fast AFC.
112 112  * Packet engine up to 256 bytes with CRC
113 113  
110 +
114 114  == 1.3 Features ==
115 115  
113 +
116 116  * LoRaWAN Class A & Class C protocol (default Class C)
117 117  * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
118 118  * AT Commands to change parameters
... ... @@ -122,8 +122,10 @@
122 122  * Support Modbus protocol
123 123  * Support Interrupt uplink (Since hardware version v1.2)
124 124  
123 +
125 125  == 1.4 Applications ==
126 126  
126 +
127 127  * Smart Buildings & Home Automation
128 128  * Logistics and Supply Chain Management
129 129  * Smart Metering
... ... @@ -131,13 +131,17 @@
131 131  * Smart Cities
132 132  * Smart Factory
133 133  
134 +
134 134  == 1.5 Firmware Change log ==
135 135  
137 +
136 136  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
137 137  
138 138  
141 +
139 139  == 1.6 Hardware Change log ==
140 140  
144 +
141 141  (((
142 142  (((
143 143  (((
... ... @@ -148,6 +148,7 @@
148 148  v1.0: Release
149 149  )))
150 150  
155 +
151 151  
152 152  )))
153 153  )))
... ... @@ -154,6 +154,7 @@
154 154  
155 155  = 2. Power ON Device =
156 156  
162 +
157 157  (((
158 158  The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
159 159  
... ... @@ -166,6 +166,7 @@
166 166  
167 167  (% aria-label="1653268091319-405.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268091319-405.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
168 168  
175 +
169 169  
170 170  )))
171 171  
... ... @@ -173,16 +173,19 @@
173 173  
174 174  == 3.1 How it works? ==
175 175  
183 +
176 176  (((
177 177  (((
178 178  The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
179 179  )))
180 180  
189 +
181 181  
182 182  )))
183 183  
184 184  == 3.2 Example to join LoRaWAN network ==
185 185  
195 +
186 186  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
187 187  
188 188  (% aria-label="1653268155545-638.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268155545-638.png||data-widget="image" height="334" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -252,8 +252,10 @@
252 252  (% aria-label="1652953568895-172.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953568895-172.png||data-widget="image" height="232" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
253 253  
254 254  
265 +
255 255  == 3.3 Configure Commands to read data ==
256 256  
268 +
257 257  (((
258 258  (((
259 259  (((
... ... @@ -263,15 +263,17 @@
263 263  
264 264  (((
265 265  (((
266 -(% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
278 +(% style="color:red" %)**Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1**
267 267  )))
268 268  
281 +
269 269  
270 270  )))
271 271  )))
272 272  
273 -=== 3.3.1 onfigure UART settings for RS485 or TTL communication ===
286 +=== 3.3.1 Configure UART settings for RS485 or TTL communication ===
274 274  
288 +
275 275  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
276 276  
277 277  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
... ... @@ -332,11 +332,15 @@
332 332  )))
333 333  )))
334 334  
349 +
335 335  === 3.3.2 Configure sensors ===
336 336  
352 +
337 337  (((
338 338  (((
339 -Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won’t run during each sampling.
355 +Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling.
356 +
357 +
340 340  )))
341 341  )))
342 342  
... ... @@ -356,8 +356,10 @@
356 356  )))
357 357  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
358 358  
377 +
359 359  === 3.3.3 Configure read commands for each sampling ===
360 360  
380 +
361 361  (((
362 362  During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload.
363 363  
... ... @@ -431,6 +431,7 @@
431 431  
432 432  === 3.3.4 Compose the uplink payload ===
433 433  
454 +
434 434  (((
435 435  Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
436 436  
... ... @@ -489,7 +489,7 @@
489 489  DATA3=the rest of Valid value of RETURN10= **30**
490 490  
491 491  
492 -(% style="color:red" %)Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:
513 +(% style="color:red" %)**Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:**
493 493  
494 494   ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink.
495 495  
... ... @@ -508,6 +508,7 @@
508 508  
509 509  === 3.3.5 Uplink on demand ===
510 510  
532 +
511 511  Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command.
512 512  
513 513  Downlink control command:
... ... @@ -520,6 +520,7 @@
520 520  
521 521  === 3.3.6 Uplink on Interrupt ===
522 522  
545 +
523 523  RS485-LN support external Interrupt uplink since hardware v1.2 release.
524 524  
525 525  (% aria-label="1654157342174-798.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157342174-798.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -527,6 +527,7 @@
527 527  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
528 528  
529 529  
553 +
530 530  == 3.4 Uplink Payload ==
531 531  
532 532  
... ... @@ -535,8 +535,10 @@
535 535  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
536 536  
537 537  
562 +
538 538  == 3.5 Configure RS485-LN via AT or Downlink ==
539 539  
565 +
540 540  (((
541 541  User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
542 542  )))
... ... @@ -558,13 +558,17 @@
558 558  )))
559 559  
560 560  
587 +
561 561  === 3.5.1 Common Commands ===
562 562  
590 +
563 563  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
564 564  
565 565  
566 -=== 3.5.2 Sensor related commands ===
567 567  
595 +=== 3.5.2 Downlink Response(Since firmware v1.4) ===
596 +
597 +
568 568  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
569 569  
570 570  (% aria-label="image-20220602163333-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602163333-5.png||data-widget="image" height="263" width="1160"]](% title="Click and drag to resize" %)​
... ... @@ -581,7 +581,7 @@
581 581  ==== (% style="color:blue" %)**RS485 Debug Command**(%%) ====
582 582  
583 583  (((
584 -This command is used to configure the RS485 devices; they wont be used during sampling.
614 +This command is used to configure the RS485 devices; they won't be used during sampling.
585 585  )))
586 586  
587 587  * (((
... ... @@ -1079,6 +1079,7 @@
1079 1079  
1080 1080  == 3.6 Listening mode for RS485 network ==
1081 1081  
1112 +
1082 1082  (((
1083 1083  This feature support since firmware v1.4
1084 1084  )))
... ... @@ -1085,6 +1085,8 @@
1085 1085  
1086 1086  (((
1087 1087  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1119 +
1120 +
1088 1088  )))
1089 1089  
1090 1090  (% aria-label="image-20220602171200-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602171200-8.png||data-widget="image" height="567" width="1007"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -1170,11 +1170,12 @@
1170 1170  
1171 1171  (((
1172 1172  (((
1173 -(% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1206 +(% style="color:red" %)**Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.**
1174 1174  )))
1175 1175  )))
1176 1176  
1177 1177  
1211 +
1178 1178  == 3.7 Buttons ==
1179 1179  
1180 1180  
... ... @@ -1196,13 +1196,16 @@
1196 1196  
1197 1197  = 4. Case Study =
1198 1198  
1233 +
1199 1199  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1200 1200  
1201 1201  
1237 +
1202 1202  = 5. Use AT Command =
1203 1203  
1204 1204  == 5.1 Access AT Command ==
1205 1205  
1242 +
1206 1206  (((
1207 1207  RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below.
1208 1208  )))
... ... @@ -1228,6 +1228,7 @@
1228 1228  
1229 1229  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1230 1230  
1268 +
1231 1231  If device has not joined network yet:
1232 1232  
1233 1233  * (% style="color:#037691" %)**AT+FDR**
... ... @@ -1246,6 +1246,7 @@
1246 1246  )))
1247 1247  
1248 1248  
1287 +
1249 1249  === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1250 1250  
1251 1251  
... ... @@ -1282,10 +1282,12 @@
1282 1282  (% aria-label="1654162478620-421.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162478620-421.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1283 1283  
1284 1284  
1324 +
1285 1285  = 6. FAQ =
1286 1286  
1287 1287  == 6.1 How to upgrade the image? ==
1288 1288  
1329 +
1289 1289  (((
1290 1290  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1291 1291  )))
... ... @@ -1304,14 +1304,16 @@
1304 1304  Below shows the hardware connection for how to upload an image to RS485-LN:
1305 1305  )))
1306 1306  
1307 -(% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1348 +(% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
1308 1308  
1350 +(% title="Click and drag to resize" %)​
1351 +
1309 1309  (((
1310 1310  (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1311 1311  )))
1312 1312  
1313 1313  (((
1314 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1357 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Firmware/]].
1315 1315  )))
1316 1316  
1317 1317  (((
... ... @@ -1336,47 +1336,69 @@
1336 1336  (% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1337 1337  
1338 1338  
1339 -(% style="color:red" %)**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1382 +(% style="color:red" %)**Notice**: **In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:**
1340 1340  
1341 1341  (% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1342 1342  
1343 1343  
1387 +
1344 1344  == 6.2 How to change the LoRa Frequency Bands/Region? ==
1345 1345  
1390 +
1346 1346  User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1347 1347  
1348 1348  
1394 +
1349 1349  == 6.3 How many RS485-Slave can RS485-LN connects? ==
1350 1350  
1397 +
1351 1351  The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1352 1352  
1353 1353  
1401 +
1354 1354  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
1355 1355  
1404 +
1356 1356  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1357 1357  
1358 1358  Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1359 1359  
1360 1360  
1410 +
1361 1361  == 6.5 Can i use point to point communication for RS485-LN? ==
1362 1362  
1413 +
1363 1363  Yes, please refer [[Point to Point Communication for RS485-LN>>Point to Point Communication for RS485-LN]].
1364 1364  
1365 1365  
1417 +
1418 +== 6.6 How to Use RS485-LN  to connect to RS232 devices? ==
1419 +
1420 +
1421 +[[Use RS485-BL or RS485-LN to connect to RS232 devices. - DRAGINO>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/RS485%20to%20RS232/]]
1422 +
1423 +
1424 +
1366 1366  = 7. Trouble Shooting =
1367 1367  
1427 +
1368 1368  == 7.1 Downlink doesn't work, how to solve it? ==
1369 1369  
1430 +
1370 1370  Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1371 1371  
1372 1372  
1434 +
1373 1373  == 7.2 Why I can't join TTN V3 in US915 /AU915 bands? ==
1374 1374  
1437 +
1375 1375  It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1376 1376  
1377 1377  
1441 +
1378 1378  = 8. Order Info =
1379 1379  
1444 +
1380 1380  (% style="color:blue" %)**Part Number: RS485-LN-XXX**
1381 1381  
1382 1382  (% style="color:blue" %)**XXX:**
... ... @@ -1412,6 +1412,7 @@
1412 1412  
1413 1413  = 10. FCC Caution for RS485LN-US915 =
1414 1414  
1480 +
1415 1415  (((
1416 1416  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1417 1417  )))
... ... @@ -1461,8 +1461,10 @@
1461 1461  )))
1462 1462  
1463 1463  
1530 +
1464 1464  = 11. Support =
1465 1465  
1533 +
1466 1466  * (((
1467 1467  Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1468 1468  )))
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0