<
From version < 62.8 >
edited by Xiaoling
on 2022/06/30 10:22
To version < 68.1 >
edited by Bei Jinggeng
on 2022/08/06 09:30
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -112,8 +112,10 @@
112 112  * Packet engine up to 256 bytes with CRC
113 113  
114 114  
115 +
115 115  == 1.3 Features ==
116 116  
118 +
117 117  * LoRaWAN Class A & Class C protocol (default Class C)
118 118  * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
119 119  * AT Commands to change parameters
... ... @@ -124,8 +124,10 @@
124 124  * Support Interrupt uplink (Since hardware version v1.2)
125 125  
126 126  
129 +
127 127  == 1.4 Applications ==
128 128  
132 +
129 129  * Smart Buildings & Home Automation
130 130  * Logistics and Supply Chain Management
131 131  * Smart Metering
... ... @@ -134,13 +134,17 @@
134 134  * Smart Factory
135 135  
136 136  
141 +
137 137  == 1.5 Firmware Change log ==
138 138  
144 +
139 139  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
140 140  
141 141  
148 +
142 142  == 1.6 Hardware Change log ==
143 143  
151 +
144 144  (((
145 145  (((
146 146  (((
... ... @@ -151,6 +151,7 @@
151 151  v1.0: Release
152 152  )))
153 153  
162 +
154 154  
155 155  )))
156 156  )))
... ... @@ -157,6 +157,7 @@
157 157  
158 158  = 2. Power ON Device =
159 159  
169 +
160 160  (((
161 161  The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
162 162  
... ... @@ -169,6 +169,7 @@
169 169  
170 170  (% aria-label="1653268091319-405.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268091319-405.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
171 171  
182 +
172 172  
173 173  )))
174 174  
... ... @@ -176,16 +176,19 @@
176 176  
177 177  == 3.1 How it works? ==
178 178  
190 +
179 179  (((
180 180  (((
181 181  The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
182 182  )))
183 183  
196 +
184 184  
185 185  )))
186 186  
187 187  == 3.2 Example to join LoRaWAN network ==
188 188  
202 +
189 189  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
190 190  
191 191  (% aria-label="1653268155545-638.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1653268155545-638.png||data-widget="image" height="334" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -255,8 +255,10 @@
255 255  (% aria-label="1652953568895-172.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1652953568895-172.png||data-widget="image" height="232" width="724"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
256 256  
257 257  
272 +
258 258  == 3.3 Configure Commands to read data ==
259 259  
275 +
260 260  (((
261 261  (((
262 262  (((
... ... @@ -266,15 +266,17 @@
266 266  
267 267  (((
268 268  (((
269 -(% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
285 +(% style="color:red" %)**Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1**
270 270  )))
271 271  
288 +
272 272  
273 273  )))
274 274  )))
275 275  
276 -=== 3.3.1 onfigure UART settings for RS485 or TTL communication ===
293 +=== 3.3.1 Configure UART settings for RS485 or TTL communication ===
277 277  
295 +
278 278  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
279 279  
280 280  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
... ... @@ -338,6 +338,7 @@
338 338  
339 339  === 3.3.2 Configure sensors ===
340 340  
359 +
341 341  (((
342 342  (((
343 343  Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won’t run during each sampling.
... ... @@ -360,8 +360,10 @@
360 360  )))
361 361  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
362 362  
382 +
363 363  === 3.3.3 Configure read commands for each sampling ===
364 364  
385 +
365 365  (((
366 366  During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload.
367 367  
... ... @@ -435,6 +435,7 @@
435 435  
436 436  === 3.3.4 Compose the uplink payload ===
437 437  
459 +
438 438  (((
439 439  Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
440 440  
... ... @@ -493,7 +493,7 @@
493 493  DATA3=the rest of Valid value of RETURN10= **30**
494 494  
495 495  
496 -(% style="color:red" %)Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:
518 +(% style="color:red" %)**Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:**
497 497  
498 498   ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink.
499 499  
... ... @@ -512,6 +512,7 @@
512 512  
513 513  === 3.3.5 Uplink on demand ===
514 514  
537 +
515 515  Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command.
516 516  
517 517  Downlink control command:
... ... @@ -524,6 +524,7 @@
524 524  
525 525  === 3.3.6 Uplink on Interrupt ===
526 526  
550 +
527 527  RS485-LN support external Interrupt uplink since hardware v1.2 release.
528 528  
529 529  (% aria-label="1654157342174-798.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157342174-798.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -531,6 +531,7 @@
531 531  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
532 532  
533 533  
558 +
534 534  == 3.4 Uplink Payload ==
535 535  
536 536  
... ... @@ -539,8 +539,10 @@
539 539  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
540 540  
541 541  
567 +
542 542  == 3.5 Configure RS485-LN via AT or Downlink ==
543 543  
570 +
544 544  (((
545 545  User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
546 546  )))
... ... @@ -562,13 +562,17 @@
562 562  )))
563 563  
564 564  
592 +
565 565  === 3.5.1 Common Commands ===
566 566  
595 +
567 567  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
568 568  
569 569  
599 +
570 570  === 3.5.2 Sensor related commands ===
571 571  
602 +
572 572  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
573 573  
574 574  (% aria-label="image-20220602163333-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602163333-5.png||data-widget="image" height="263" width="1160"]](% title="Click and drag to resize" %)​
... ... @@ -1083,6 +1083,7 @@
1083 1083  
1084 1084  == 3.6 Listening mode for RS485 network ==
1085 1085  
1117 +
1086 1086  (((
1087 1087  This feature support since firmware v1.4
1088 1088  )))
... ... @@ -1089,6 +1089,8 @@
1089 1089  
1090 1090  (((
1091 1091  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1124 +
1125 +
1092 1092  )))
1093 1093  
1094 1094  (% aria-label="image-20220602171200-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602171200-8.png||data-widget="image" height="567" width="1007"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
... ... @@ -1174,11 +1174,12 @@
1174 1174  
1175 1175  (((
1176 1176  (((
1177 -(% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1211 +(% style="color:red" %)**Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.**
1178 1178  )))
1179 1179  )))
1180 1180  
1181 1181  
1216 +
1182 1182  == 3.7 Buttons ==
1183 1183  
1184 1184  
... ... @@ -1189,7 +1189,6 @@
1189 1189  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1190 1190  
1191 1191  
1192 -
1193 1193  == 3.8 LEDs ==
1194 1194  
1195 1195  
... ... @@ -1199,16 +1199,18 @@
1199 1199  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1200 1200  
1201 1201  
1202 -
1203 1203  = 4. Case Study =
1204 1204  
1238 +
1205 1205  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1206 1206  
1207 1207  
1242 +
1208 1208  = 5. Use AT Command =
1209 1209  
1210 1210  == 5.1 Access AT Command ==
1211 1211  
1247 +
1212 1212  (((
1213 1213  RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below.
1214 1214  )))
... ... @@ -1234,6 +1234,7 @@
1234 1234  
1235 1235  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1236 1236  
1273 +
1237 1237  If device has not joined network yet:
1238 1238  
1239 1239  * (% style="color:#037691" %)**AT+FDR**
... ... @@ -1252,6 +1252,7 @@
1252 1252  )))
1253 1253  
1254 1254  
1292 +
1255 1255  === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1256 1256  
1257 1257  
... ... @@ -1288,10 +1288,12 @@
1288 1288  (% aria-label="1654162478620-421.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162478620-421.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1289 1289  
1290 1290  
1329 +
1291 1291  = 6. FAQ =
1292 1292  
1293 1293  == 6.1 How to upgrade the image? ==
1294 1294  
1334 +
1295 1295  (((
1296 1296  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1297 1297  )))
... ... @@ -1317,7 +1317,7 @@
1317 1317  )))
1318 1318  
1319 1319  (((
1320 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1360 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dragino.com/downloads/index.php?dir=RS485-LN/Firmware/]].
1321 1321  )))
1322 1322  
1323 1323  (((
... ... @@ -1342,42 +1342,69 @@
1342 1342  (% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1343 1343  
1344 1344  
1345 -(% style="color:red" %)**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1385 +(% style="color:red" %)**Notice**: **In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:**
1346 1346  
1347 1347  (% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
1348 1348  
1349 1349  
1390 +
1350 1350  == 6.2 How to change the LoRa Frequency Bands/Region? ==
1351 1351  
1393 +
1352 1352  User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1353 1353  
1354 1354  
1397 +
1355 1355  == 6.3 How many RS485-Slave can RS485-LN connects? ==
1356 1356  
1400 +
1357 1357  The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1358 1358  
1359 1359  
1404 +
1360 1360  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
1361 1361  
1407 +
1362 1362  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1363 1363  
1364 1364  Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1365 1365  
1366 1366  
1413 +
1414 +== 6.5 Can i use point to point communication for RS485-LN? ==
1415 +
1416 +
1417 +Yes, please refer [[Point to Point Communication for RS485-LN>>Point to Point Communication for RS485-LN]].
1418 +
1419 +
1420 +
1421 +== 6.6 How to Use RS485-LN  to connect to RS232 devices? ==
1422 +
1423 +
1424 +[[Use RS485-BL or RS485-LN to connect to RS232 devices. - DRAGINO>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/RS485%20to%20RS232/]]
1425 +
1426 +
1427 +
1367 1367  = 7. Trouble Shooting =
1368 1368  
1369 -== 7.1 Downlink doesn’t work, how to solve it? ==
1370 1370  
1431 +== 7.1 Downlink doesn't work, how to solve it? ==
1432 +
1433 +
1371 1371  Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1372 1372  
1373 1373  
1374 -== 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1375 1375  
1438 +== 7.2 Why I can't join TTN V3 in US915 /AU915 bands? ==
1439 +
1440 +
1376 1376  It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1377 1377  
1378 1378  
1444 +
1379 1379  = 8. Order Info =
1380 1380  
1447 +
1381 1381  (% style="color:blue" %)**Part Number: RS485-LN-XXX**
1382 1382  
1383 1383  (% style="color:blue" %)**XXX:**
... ... @@ -1393,6 +1393,8 @@
1393 1393  * (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1394 1394  * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1395 1395  
1463 +
1464 +
1396 1396  = 9.Packing Info =
1397 1397  
1398 1398  
... ... @@ -1409,8 +1409,12 @@
1409 1409  * Package Size / pcs : 14.5 x 8 x 5 cm
1410 1410  * Weight / pcs : 170g
1411 1411  
1481 +
1482 +
1483 +
1412 1412  = 10. FCC Caution for RS485LN-US915 =
1413 1413  
1486 +
1414 1414  (((
1415 1415  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
1416 1416  )))
... ... @@ -1460,8 +1460,10 @@
1460 1460  )))
1461 1461  
1462 1462  
1536 +
1463 1463  = 11. Support =
1464 1464  
1539 +
1465 1465  * (((
1466 1466  Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1467 1467  )))
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0