Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,11 +12,6 @@ 12 12 13 13 14 14 15 - 16 - 17 - 18 - 19 - 20 20 **Table of Contents:** 21 21 22 22 {{toc/}} ... ... @@ -85,11 +85,13 @@ 85 85 ** Idle: 32mA@12v 86 86 ** 20dB Transmit: 65mA@12v 87 87 83 + 88 88 **Interface for Model:** 89 89 90 90 * RS485 91 91 * Power Input 7~~ 24V DC. 92 92 89 + 93 93 **LoRa Spec:** 94 94 95 95 * Frequency Range: ... ... @@ -113,6 +113,7 @@ 113 113 114 114 115 115 113 + 116 116 == 1.3 Features == 117 117 118 118 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -126,6 +126,7 @@ 126 126 127 127 128 128 127 + 129 129 == 1.4 Applications == 130 130 131 131 * Smart Buildings & Home Automation ... ... @@ -137,6 +137,7 @@ 137 137 138 138 139 139 139 + 140 140 == 1.5 Firmware Change log == 141 141 142 142 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -339,7 +339,6 @@ 339 339 ))) 340 340 341 341 342 - 343 343 === 3.3.2 Configure sensors === 344 344 345 345 ((( ... ... @@ -581,13 +581,12 @@ 581 581 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 582 582 583 583 584 - 585 585 === 3.5.3 Sensor related commands === 586 586 587 587 588 588 589 589 590 -==== (% style="color: blue" %)**RS485 Debug Command**(%%) ====588 +==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ==== 591 591 592 592 ((( 593 593 This command is used to configure the RS485 devices; they won’t be used during sampling. ... ... @@ -594,15 +594,15 @@ 594 594 ))) 595 595 596 596 * ((( 597 -(% style="color:#037691" %) **AT Command**595 +**(% style="color:#037691" %)AT Command** 598 598 599 -((( 600 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 597 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 598 + 599 + 601 601 ))) 602 -))) 603 603 604 604 ((( 605 - 603 +m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 606 606 ))) 607 607 608 608 * ((( ... ... @@ -643,9 +643,7 @@ 643 643 ))) 644 644 645 645 ((( 646 - 647 - 648 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 644 +**Example 1** ~-~-> Configure without ask for uplink (YY=0) 649 649 ))) 650 650 651 651 ((( ... ... @@ -661,8 +661,6 @@ 661 661 ))) 662 662 663 663 ((( 664 - 665 - 666 666 So if user want to use downlink command to control to RS485 Alarm, he can use: 667 667 ))) 668 668 ... ... @@ -683,7 +683,7 @@ 683 683 ))) 684 684 685 685 ((( 686 -**Example 2** 680 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 687 687 ))) 688 688 689 689 ((( ... ... @@ -695,11 +695,11 @@ 695 695 ))) 696 696 697 697 ((( 698 -((( 699 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 692 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 700 700 ))) 701 701 702 - 695 +((( 696 + **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 703 703 ))) 704 704 705 705 ((( ... ... @@ -709,7 +709,7 @@ 709 709 710 710 711 711 712 -==== (% style="color:blue" %) **Set Payload version**(%%)====706 +==== **(% style="color:blue" %)Set Payload version** ==== 713 713 714 714 ((( 715 715 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -716,28 +716,32 @@ 716 716 ))) 717 717 718 718 * ((( 719 -(% style="color:#037691" %)**AT Command:** 713 +**(% style="color:#037691" %)AT Command:** 714 +))) 720 720 721 -**AT+PAYVER: **Set PAYVER field = 1 722 - 723 - 716 +(% class="box infomessage" %) 717 +((( 718 +((( 719 +**AT+PAYVER: Set PAYVER field = 1** 724 724 ))) 721 +))) 722 + 725 725 * ((( 726 -(% style="color:#037691" %) **Downlink Payload:**724 +**(% style="color:#037691" %)Downlink Payload:** 727 727 ))) 728 728 729 729 ((( 730 -**0xAE 01** ~-~-> 728 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 731 731 ))) 732 732 733 733 ((( 734 -**0xAE 0F** ~-~-> 732 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 735 735 ))) 736 736 737 737 738 738 739 739 740 -==== (% style="color:blue" %) **Set RS485 Sampling Commands**(%%)====738 +==== **(% style="color:blue" %)Set RS485 Sampling Commands** ==== 741 741 742 742 ((( 743 743 AT+COMMANDx or AT+DATACUTx ... ... @@ -752,16 +752,18 @@ 752 752 ))) 753 753 754 754 * ((( 755 -(% style="color:#037691" %) **AT Command:**753 +**(% style="color:#037691" %)AT Command:** 756 756 ))) 757 757 758 -**AT+COMMANDx: **Configure RS485 read command to sensor. 759 759 760 -**AT+ DATACUTx:**Configurehowtohandlereturn fromRS485 devices.757 +**AT+COMMANDx: Configure RS485 read command to sensor.** 761 761 762 762 760 +**AT+DATACUTx: Configure how to handle return from RS485 devices.** 761 + 762 + 763 763 * ((( 764 -(% style="color:#037691" %) **Downlink Payload:**764 +**(% style="color:#037691" %)Downlink Payload:** 765 765 ))) 766 766 767 767 ((( ... ... @@ -797,8 +797,6 @@ 797 797 ))) 798 798 799 799 ((( 800 - 801 - 802 802 **Example:** 803 803 ))) 804 804 ... ... @@ -817,10 +817,10 @@ 817 817 818 818 819 819 820 -==== (% style="color:blue" %) **Fast command to handle MODBUS device**(%%)====818 +==== **(% style="color:blue" %)Fast command to handle MODBUS device** ==== 821 821 822 822 ((( 823 - **AT+MBFUN**is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].821 +AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 824 824 ))) 825 825 826 826 ((( ... ... @@ -840,25 +840,23 @@ 840 840 ))) 841 841 842 842 * ((( 843 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 841 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 844 844 ))) 845 845 * ((( 846 -AT+COMMAND1= 01 03 00 10 00 08,1 844 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 847 847 ))) 848 848 * ((( 849 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 850 - 851 - 847 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 852 852 ))) 853 853 854 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %) 850 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 855 855 856 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %) 852 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 857 857 858 858 859 859 860 860 861 -==== (% style="color:blue" %) **RS485 command timeout**(%%)====857 +==== **(% style="color:blue" %)RS485 command timeout** ==== 862 862 863 863 ((( 864 864 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. ... ... @@ -869,14 +869,17 @@ 869 869 ))) 870 870 871 871 * ((( 872 -(% style="color:#037691" %)** AT Command:** 868 +**(% style="color:#037691" %) AT Command:** 869 +))) 873 873 871 +(% class="box infomessage" %) 872 +((( 873 +((( 874 874 **AT+CMDDLaa=hex(bb cc)*1000** 875 875 ))) 876 +))) 876 876 877 877 ((( 878 - 879 - 880 880 **Example:** 881 881 ))) 882 882 ... ... @@ -889,7 +889,7 @@ 889 889 ))) 890 890 891 891 * ((( 892 -(% style="color:#037691" %) **Downlink Payload:**891 +**(% style="color:#037691" %) Downlink Payload:** 893 893 ))) 894 894 895 895 ((( ... ... @@ -901,17 +901,17 @@ 901 901 ))) 902 902 903 903 ((( 904 -**Example:** 903 + **Example:** 905 905 ))) 906 906 907 907 ((( 908 - **0xAA 01 00 01**907 + 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 909 909 ))) 910 910 911 911 912 912 913 913 914 -==== (% style="color:blue" %) **Uplink payload mode**(%%)====913 +==== **(% style="color:blue" %)Uplink payload mode** ==== 915 915 916 916 ((( 917 917 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -919,14 +919,13 @@ 919 919 920 920 ((( 921 921 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 922 - 923 - 924 924 ))) 925 925 926 926 * ((( 927 -(% style="color:#037691" %) **AT Command:**924 +**(% style="color:#037691" %) AT Command:** 928 928 ))) 929 929 927 + 930 930 **AT+DATAUP=0** 931 931 932 932 **AT+DATAUP=1** ... ... @@ -933,7 +933,7 @@ 933 933 934 934 935 935 * ((( 936 -(% style="color:#037691" %) **Downlink Payload:**934 +**(% style="color:#037691" %) Downlink Payload:** 937 937 ))) 938 938 939 939 ((( ... ... @@ -947,7 +947,7 @@ 947 947 948 948 949 949 950 -==== (% style="color:blue" %) **Manually trigger an Uplink**(%%)====948 +==== **(% style="color:blue" %)Manually trigger an Uplink** ==== 951 951 952 952 ((( 953 953 Ask device to send an uplink immediately. ... ... @@ -954,7 +954,7 @@ 954 954 ))) 955 955 956 956 * ((( 957 -(% style="color:#037691" %) **AT Command:**955 +**(% style="color:#037691" %) AT Command:** 958 958 ))) 959 959 960 960 ((( ... ... @@ -966,7 +966,7 @@ 966 966 ))) 967 967 968 968 * ((( 969 -(% style="color:#037691" %) **Downlink Payload:**967 +**(% style="color:#037691" %) Downlink Payload:** 970 970 ))) 971 971 972 972 ((( ... ... @@ -976,16 +976,14 @@ 976 976 977 977 978 978 979 -==== (% style="color:blue" %) **Clear RS485 Command**(%%)====977 +==== **(% style="color:blue" %)Clear RS485 Command** ==== 980 980 981 981 ((( 982 982 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 983 - 984 - 985 985 ))) 986 986 987 987 * ((( 988 -(% style="color:#037691" %) **AT Command:**984 +**(% style="color:#037691" %) AT Command:** 989 989 ))) 990 990 991 991 ((( ... ... @@ -1012,7 +1012,7 @@ 1012 1012 1013 1013 1014 1014 * ((( 1015 -(% style="color:#037691" %) **Downlink Payload:**1011 +**(% style="color:#037691" %) Downlink Payload:** 1016 1016 ))) 1017 1017 1018 1018 ((( ... ... @@ -1022,7 +1022,7 @@ 1022 1022 1023 1023 1024 1024 1025 -==== (% style="color:blue" %) **Set Serial Communication Parameters**(%%)====1021 +==== **(% style="color:blue" %)Set Serial Communication Parameters** ==== 1026 1026 1027 1027 ((( 1028 1028 Set the Rs485 serial communication parameters: ... ... @@ -1029,39 +1029,39 @@ 1029 1029 ))) 1030 1030 1031 1031 * ((( 1032 -(% style="color:#037691" %) **AT Command:**1028 +**(% style="color:#037691" %) AT Command:** 1033 1033 ))) 1034 1034 1035 1035 ((( 1036 - 1037 - 1038 -* Set Baud Rate 1032 +Set Baud Rate: 1039 1039 ))) 1040 1040 1035 + 1041 1041 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1042 1042 1043 1043 1044 1044 ((( 1045 - *Set UART Parity1040 +Set UART Parity 1046 1046 ))) 1047 1047 1043 + 1048 1048 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1049 1049 1050 1050 1051 1051 ((( 1052 - *Set STOPBIT1048 +Set STOPBIT 1053 1053 ))) 1054 1054 1051 + 1055 1055 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1056 1056 1057 1057 1058 - 1059 1059 * ((( 1060 -(% style="color:#037691" %) **Downlink Payload:**1056 +**(% style="color:#037691" %) Downlink Payload:** 1061 1061 ))) 1062 1062 1063 1063 ((( 1064 -**A7 01 aa bb**: 1060 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1065 1065 ))) 1066 1066 1067 1067 ((( ... ... @@ -1076,11 +1076,11 @@ 1076 1076 ))) 1077 1077 1078 1078 ((( 1079 -A7 02 aa: 1075 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1080 1080 ))) 1081 1081 1082 1082 ((( 1083 -A7 03 aa: 1079 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1084 1084 ))) 1085 1085 1086 1086 ... ... @@ -1134,7 +1134,7 @@ 1134 1134 ))) 1135 1135 1136 1136 ((( 1137 - (% style="color:#037691" %)**1133 +**Downlink Command:** 1138 1138 ))) 1139 1139 1140 1140 ((( ... ... @@ -1232,24 +1232,38 @@ 1232 1232 1233 1233 == 5.2 Common AT Command Sequence == 1234 1234 1235 - 1236 1236 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1237 1237 1238 1238 If device has not joined network yet: 1239 1239 1240 -* (% style="color:#037691" %)**AT+FDR** 1241 -* (% style="color:#037691" %)**AT+NJM=0** 1242 -* (% style="color:#037691" %)**ATZ** 1235 +(% class="box infomessage" %) 1236 +((( 1237 +**AT+FDR** 1238 +))) 1243 1243 1240 +(% class="box infomessage" %) 1244 1244 ((( 1245 - 1242 +**AT+NJM=0** 1243 +))) 1246 1246 1245 +(% class="box infomessage" %) 1246 +((( 1247 +**ATZ** 1248 +))) 1249 + 1250 + 1251 +((( 1247 1247 If device already joined network: 1253 +))) 1248 1248 1249 -* (% style="color:#037691" %)**AT+NJM=0** 1250 -* (% style="color:#037691" %)**ATZ** 1255 +(% class="box infomessage" %) 1256 +((( 1257 +**AT+NJM=0** 1258 +))) 1251 1251 1252 - 1260 +(% class="box infomessage" %) 1261 +((( 1262 +**ATZ** 1253 1253 ))) 1254 1254 1255 1255 ... ... @@ -1256,25 +1256,25 @@ 1256 1256 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1257 1257 1258 1258 1259 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) 1269 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1260 1260 1261 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) 1271 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1262 1262 1263 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) 1273 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1264 1264 1265 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) 1275 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1266 1266 1267 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) 1277 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1268 1268 1269 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) 1279 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1270 1270 1271 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) 1281 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1272 1272 1273 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) 1283 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1274 1274 1275 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 1285 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1276 1276 1277 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) 1287 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1278 1278 1279 1279 1280 1280 (% style="color:red" %)**Note:** ... ... @@ -1314,15 +1314,15 @@ 1314 1314 (% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1315 1315 1316 1316 ((( 1317 - (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].1327 +**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1318 1318 ))) 1319 1319 1320 1320 ((( 1321 - (% style="color:blue" %)**Step2**(%%)**:**Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].1331 +**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1322 1322 ))) 1323 1323 1324 1324 ((( 1325 - (% style="color:blue" %)**Step3**(%%)**: **Open flashloader; choose the correct COM port to update.1335 +**Step3: **Open flashloader; choose the correct COM port to update. 1326 1326 ))) 1327 1327 1328 1328 ((( ... ... @@ -1343,7 +1343,7 @@ 1343 1343 (% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1344 1344 1345 1345 1346 - (% style="color:red" %)**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:1356 +**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1347 1347 1348 1348 (% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1349 1349 ... ... @@ -1383,16 +1383,16 @@ 1383 1383 1384 1384 (% style="color:blue" %)**XXX:** 1385 1385 1386 -* (% style="color: red" %)**EU433**(%%):1387 -* (% style="color: red" %)**EU868**(%%):1388 -* (% style="color: red" %)**KR920**(%%):1389 -* (% style="color: red" %)**CN470**(%%):1390 -* (% style="color: red" %)**AS923**(%%):1391 -* (% style="color: red" %)**AU915**(%%):1392 -* (% style="color: red" %)**US915**(%%):1393 -* (% style="color: red" %)**IN865**(%%):1394 -* (% style="color: red" %)**RU864**(%%):1395 -* (% style="color: red" %)**KZ865**(%%):1396 +* (% style="color:blue" %)**EU433**(%%): frequency bands EU433 1397 +* (% style="color:blue" %)**EU868**(%%): frequency bands EU868 1398 +* (% style="color:blue" %)**KR920**(%%): frequency bands KR920 1399 +* (% style="color:blue" %)**CN470**(%%): frequency bands CN470 1400 +* (% style="color:blue" %)**AS923**(%%): frequency bands AS923 1401 +* (% style="color:blue" %)**AU915**(%%): frequency bands AU915 1402 +* (% style="color:blue" %)**US915**(%%): frequency bands US915 1403 +* (% style="color:blue" %)**IN865**(%%): frequency bands IN865 1404 +* (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1405 +* (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1396 1396 1397 1397 = 9.Packing Info = 1398 1398 ... ... @@ -1425,7 +1425,7 @@ 1425 1425 ))) 1426 1426 1427 1427 ((( 1428 - (% style="color:red" %)**IMPORTANT NOTE:**1438 +**IMPORTANT NOTE:** 1429 1429 ))) 1430 1430 1431 1431 ((( ... ... @@ -1453,7 +1453,7 @@ 1453 1453 ))) 1454 1454 1455 1455 ((( 1456 - (% style="color:red" %)**FCC Radiation Exposure Statement:**1466 +**FCC Radiation Exposure Statement:** 1457 1457 ))) 1458 1458 1459 1459 (((