Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -111,8 +111,6 @@ 111 111 * Automatic RF Sense and CAD with ultra-fast AFC. 112 112 * Packet engine up to 256 bytes with CRC 113 113 114 - 115 - 116 116 == 1.3 Features == 117 117 118 118 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -124,8 +124,6 @@ 124 124 * Support Modbus protocol 125 125 * Support Interrupt uplink (Since hardware version v1.2) 126 126 127 - 128 - 129 129 == 1.4 Applications == 130 130 131 131 * Smart Buildings & Home Automation ... ... @@ -135,8 +135,6 @@ 135 135 * Smart Cities 136 136 * Smart Factory 137 137 138 - 139 - 140 140 == 1.5 Firmware Change log == 141 141 142 142 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -338,8 +338,6 @@ 338 338 ))) 339 339 ))) 340 340 341 - 342 - 343 343 === 3.3.2 Configure sensors === 344 344 345 345 ((( ... ... @@ -364,7 +364,6 @@ 364 364 ))) 365 365 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 366 366 367 - 368 368 === 3.3.3 Configure read commands for each sampling === 369 369 370 370 ((( ... ... @@ -576,17 +576,18 @@ 576 576 577 577 Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server. 578 578 579 -(% aria-label="image-20220602163333-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602163333-5.png||data-widget="image" height="263" width="1160"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag tomove" width="15"]](% title="Click and drag to resize" %)570 +(% aria-label="image-20220602163333-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602163333-5.png||data-widget="image" height="263" width="1160"]](% title="Click and drag to resize" %) 580 580 581 581 The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 582 582 583 583 575 + 584 584 === 3.5.3 Sensor related commands === 585 585 586 586 587 587 588 588 589 -==== (% style="color: #037691" %)**RS485 Debug Command**(%%) ====581 +==== (% style="color:blue" %)**RS485 Debug Command**(%%) ==== 590 590 591 591 ((( 592 592 This command is used to configure the RS485 devices; they won’t be used during sampling. ... ... @@ -1192,6 +1192,7 @@ 1192 1192 |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1193 1193 |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1194 1194 1187 + 1195 1195 == 3.8 LEDs == 1196 1196 1197 1197 ... ... @@ -1200,6 +1200,7 @@ 1200 1200 |**PWR**|Always on if there is power 1201 1201 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1202 1202 1196 + 1203 1203 = 4. Case Study = 1204 1204 1205 1205 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1364,14 +1364,19 @@ 1364 1364 Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]] 1365 1365 1366 1366 1361 +== 6.5 Can i use point to point communication for RS485-LN? == 1362 + 1363 +Yes, please refer [[Point to Point Communication for RS485-LN>>Point to Point Communication for RS485-LN]]. 1364 + 1365 + 1367 1367 = 7. Trouble Shooting = 1368 1368 1369 -== 7.1 Downlink doesn ’t work, how to solve it? ==1368 +== 7.1 Downlink doesn't work, how to solve it? == 1370 1370 1371 1371 Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]] 1372 1372 1373 1373 1374 -== 7.2 Why I can ’t join TTN V3 in US915 /AU915 bands? ==1373 +== 7.2 Why I can't join TTN V3 in US915 /AU915 bands? == 1375 1375 1376 1376 It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1377 1377 ... ... @@ -1393,6 +1393,7 @@ 1393 1393 * (% style="color:red" %)**RU864**(%%): frequency bands RU864 1394 1394 * (% style="color:red" %)**KZ865**(%%): frequency bands KZ865 1395 1395 1395 + 1396 1396 = 9.Packing Info = 1397 1397 1398 1398 ... ... @@ -1409,6 +1409,7 @@ 1409 1409 * Package Size / pcs : 14.5 x 8 x 5 cm 1410 1410 * Weight / pcs : 170g 1411 1411 1412 + 1412 1412 = 10. FCC Caution for RS485LN-US915 = 1413 1413 1414 1414 (((