Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -80,13 +80,11 @@ 80 80 ** Idle: 32mA@12v 81 81 ** 20dB Transmit: 65mA@12v 82 82 83 - 84 84 **Interface for Model:** 85 85 86 86 * RS485 87 87 * Power Input 7~~ 24V DC. 88 88 89 - 90 90 **LoRa Spec:** 91 91 92 92 * Frequency Range: ... ... @@ -110,7 +110,6 @@ 110 110 111 111 112 112 113 - 114 114 == 1.3 Features == 115 115 116 116 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -124,7 +124,6 @@ 124 124 125 125 126 126 127 - 128 128 == 1.4 Applications == 129 129 130 130 * Smart Buildings & Home Automation ... ... @@ -134,6 +134,8 @@ 134 134 * Smart Cities 135 135 * Smart Factory 136 136 133 + 134 + 137 137 == 1.5 Firmware Change log == 138 138 139 139 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -335,7 +335,6 @@ 335 335 ))) 336 336 ))) 337 337 338 - 339 339 === 3.3.2 Configure sensors === 340 340 341 341 ((( ... ... @@ -360,7 +360,6 @@ 360 360 ))) 361 361 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 362 362 363 - 364 364 === 3.3.3 Configure read commands for each sampling === 365 365 366 366 ((( ... ... @@ -591,13 +591,13 @@ 591 591 * ((( 592 592 (% style="color:#037691" %)**AT Command** 593 593 594 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 595 - 596 - 590 +((( 591 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 597 597 ))) 593 +))) 598 598 599 599 ((( 600 - m:0: no CRC, 1: add CRC-16/MODBUS in the end of this command596 + 601 601 ))) 602 602 603 603 * ((( ... ... @@ -638,7 +638,9 @@ 638 638 ))) 639 639 640 640 ((( 641 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 637 + 638 + 639 +**Example 1** ~-~-> Configure without ask for uplink (YY=0) 642 642 ))) 643 643 644 644 ((( ... ... @@ -654,6 +654,8 @@ 654 654 ))) 655 655 656 656 ((( 655 + 656 + 657 657 So if user want to use downlink command to control to RS485 Alarm, he can use: 658 658 ))) 659 659 ... ... @@ -674,7 +674,7 @@ 674 674 ))) 675 675 676 676 ((( 677 -**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 677 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 678 678 ))) 679 679 680 680 ((( ... ... @@ -686,11 +686,11 @@ 686 686 ))) 687 687 688 688 ((( 689 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 689 +((( 690 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 690 690 ))) 691 691 692 -((( 693 - **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 693 + 694 694 ))) 695 695 696 696 ((( ... ... @@ -700,7 +700,7 @@ 700 700 701 701 702 702 703 -==== **Set Payload version** ==== 703 +==== (% style="color:blue" %)**Set Payload version**(%%) ==== 704 704 705 705 ((( 706 706 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -707,32 +707,28 @@ 707 707 ))) 708 708 709 709 * ((( 710 -**AT Command:** 711 -))) 710 +(% style="color:#037691" %)**AT Command:** 712 712 713 -(% class="box infomessage" %) 714 -((( 715 -((( 716 -**AT+PAYVER: Set PAYVER field = 1** 717 -))) 718 -))) 712 +**AT+PAYVER: **Set PAYVER field = 1 719 719 714 + 715 +))) 720 720 * ((( 721 -**Downlink Payload:** 717 +(% style="color:#037691" %)**Downlink Payload:** 722 722 ))) 723 723 724 724 ((( 725 -**0xAE 01** ~-~-> Set PAYVER field = 0x01 721 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 726 726 ))) 727 727 728 728 ((( 729 -**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 725 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 730 730 ))) 731 731 732 732 733 733 734 734 735 -==== **Set RS485 Sampling Commands** ==== 731 +==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ==== 736 736 737 737 ((( 738 738 AT+COMMANDx or AT+DATACUTx ... ... @@ -747,29 +747,16 @@ 747 747 ))) 748 748 749 749 * ((( 750 -**AT Command:** 746 +(% style="color:#037691" %)**AT Command:** 751 751 ))) 752 752 753 -(% class="box infomessage" %) 754 -((( 755 -((( 756 -**AT+COMMANDx: Configure RS485 read command to sensor.** 757 -))) 758 -))) 749 +**AT+COMMANDx: **Configure RS485 read command to sensor. 759 759 760 -(% class="box infomessage" %) 761 -((( 762 -((( 763 -**AT+DATACUTx: Configure how to handle return from RS485 devices.** 764 -))) 765 -))) 751 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 766 766 767 -((( 768 - 769 -))) 770 770 771 771 * ((( 772 -**Downlink Payload:** 755 +(% style="color:#037691" %)**Downlink Payload:** 773 773 ))) 774 774 775 775 ((( ... ... @@ -805,6 +805,8 @@ 805 805 ))) 806 806 807 807 ((( 791 + 792 + 808 808 **Example:** 809 809 ))) 810 810 ... ... @@ -823,10 +823,10 @@ 823 823 824 824 825 825 826 -==== **Fast command to handle MODBUS device** ==== 811 +==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ==== 827 827 828 828 ((( 829 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 814 +**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 830 830 ))) 831 831 832 832 ((( ... ... @@ -846,23 +846,25 @@ 846 846 ))) 847 847 848 848 * ((( 849 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 834 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 850 850 ))) 851 851 * ((( 852 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 837 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 853 853 ))) 854 854 * ((( 855 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 840 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 841 + 842 + 856 856 ))) 857 857 858 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag tomove" width="15"]](% title="Click and drag to resize" %)845 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %) 859 859 860 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag tomove" width="15"]](% title="Click and drag to resize" %)847 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %) 861 861 862 862 863 863 864 864 865 -==== **RS485 command timeout** ==== 852 +==== (% style="color:blue" %)**RS485 command timeout**(%%) ==== 866 866 867 867 ((( 868 868 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. ... ... @@ -873,17 +873,14 @@ 873 873 ))) 874 874 875 875 * ((( 876 -**AT Command:** 877 -))) 863 +(% style="color:#037691" %)** AT Command:** 878 878 879 -(% class="box infomessage" %) 880 -((( 881 -((( 882 882 **AT+CMDDLaa=hex(bb cc)*1000** 883 883 ))) 884 -))) 885 885 886 886 ((( 869 + 870 + 887 887 **Example:** 888 888 ))) 889 889 ... ... @@ -896,7 +896,7 @@ 896 896 ))) 897 897 898 898 * ((( 899 -**Downlink Payload:** 883 +(% style="color:#037691" %)** Downlink Payload:** 900 900 ))) 901 901 902 902 ((( ... ... @@ -908,17 +908,17 @@ 908 908 ))) 909 909 910 910 ((( 911 - 895 +**Example:** 912 912 ))) 913 913 914 914 ((( 915 - 899 +**0xAA 01 00 01** ~-~-> Same as **AT+CMDDL1=1000 ms** 916 916 ))) 917 917 918 918 919 919 920 920 921 -==== **Uplink payload mode** ==== 905 +==== (% style="color:blue" %)**Uplink payload mode**(%%) ==== 922 922 923 923 ((( 924 924 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -926,32 +926,21 @@ 926 926 927 927 ((( 928 928 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 913 + 914 + 929 929 ))) 930 930 931 931 * ((( 932 -**AT Command:** 918 +(% style="color:#037691" %)** AT Command:** 933 933 ))) 934 934 935 -(% class="box infomessage" %) 936 -((( 937 -((( 938 938 **AT+DATAUP=0** 939 -))) 940 -))) 941 941 942 -(% class="box infomessage" %) 943 -((( 944 -((( 945 945 **AT+DATAUP=1** 946 -))) 947 -))) 948 948 949 -((( 950 - 951 -))) 952 952 953 953 * ((( 954 -**Downlink Payload:** 927 +(% style="color:#037691" %)** Downlink Payload:** 955 955 ))) 956 956 957 957 ((( ... ... @@ -965,7 +965,7 @@ 965 965 966 966 967 967 968 -==== **Manually trigger an Uplink** ==== 941 +==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ==== 969 969 970 970 ((( 971 971 Ask device to send an uplink immediately. ... ... @@ -972,7 +972,7 @@ 972 972 ))) 973 973 974 974 * ((( 975 -**AT Command:** 948 +(% style="color:#037691" %)** AT Command:** 976 976 ))) 977 977 978 978 ((( ... ... @@ -984,7 +984,7 @@ 984 984 ))) 985 985 986 986 * ((( 987 -**Downlink Payload:** 960 +(% style="color:#037691" %)** Downlink Payload:** 988 988 ))) 989 989 990 990 ((( ... ... @@ -994,14 +994,16 @@ 994 994 995 995 996 996 997 -==== **Clear RS485 Command** ==== 970 +==== (% style="color:blue" %)**Clear RS485 Command**(%%) ==== 998 998 999 999 ((( 1000 1000 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 974 + 975 + 1001 1001 ))) 1002 1002 1003 1003 * ((( 1004 -**AT Command:** 979 +(% style="color:#037691" %)** AT Command:** 1005 1005 ))) 1006 1006 1007 1007 ((( ... ... @@ -1028,7 +1028,7 @@ 1028 1028 1029 1029 1030 1030 * ((( 1031 -**Downlink Payload:** 1006 +(% style="color:#037691" %)** Downlink Payload:** 1032 1032 ))) 1033 1033 1034 1034 ((( ... ... @@ -1038,7 +1038,7 @@ 1038 1038 1039 1039 1040 1040 1041 -==== **Set Serial Communication Parameters** ==== 1016 +==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ==== 1042 1042 1043 1043 ((( 1044 1044 Set the Rs485 serial communication parameters: ... ... @@ -1045,52 +1045,39 @@ 1045 1045 ))) 1046 1046 1047 1047 * ((( 1048 -**AT Command:** 1023 +(% style="color:#037691" %)** AT Command:** 1049 1049 ))) 1050 1050 1051 1051 ((( 1052 -Set Baud Rate: 1027 + 1028 + 1029 +* Set Baud Rate 1053 1053 ))) 1054 1054 1055 -(% class="box infomessage" %) 1056 -((( 1057 -((( 1058 1058 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1059 -))) 1060 -))) 1061 1061 1034 + 1062 1062 ((( 1063 -Set UART Parity 1036 +* Set UART Parity 1064 1064 ))) 1065 1065 1066 -(% class="box infomessage" %) 1067 -((( 1068 -((( 1069 1069 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1070 -))) 1071 -))) 1072 1072 1041 + 1073 1073 ((( 1074 -Set STOPBIT 1043 +* Set STOPBIT 1075 1075 ))) 1076 1076 1077 -(% class="box infomessage" %) 1078 -((( 1079 -((( 1080 1080 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1081 -))) 1082 -))) 1083 1083 1084 -((( 1085 - 1086 -))) 1087 1087 1049 + 1088 1088 * ((( 1089 -**Downlink Payload:** 1051 +(% style="color:#037691" %)** Downlink Payload:** 1090 1090 ))) 1091 1091 1092 1092 ((( 1093 -**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1055 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1094 1094 ))) 1095 1095 1096 1096 ((( ... ... @@ -1105,11 +1105,11 @@ 1105 1105 ))) 1106 1106 1107 1107 ((( 1108 -A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1070 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1109 1109 ))) 1110 1110 1111 1111 ((( 1112 -A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1074 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1113 1113 ))) 1114 1114 1115 1115 ... ... @@ -1163,7 +1163,7 @@ 1163 1163 ))) 1164 1164 1165 1165 ((( 1166 -**Downlink Command:** 1128 +(% style="color:#037691" %)** Downlink Command:** 1167 1167 ))) 1168 1168 1169 1169 ((( ... ... @@ -1265,34 +1265,17 @@ 1265 1265 1266 1266 If device has not joined network yet: 1267 1267 1268 -(% class="box infomessage" %) 1269 -((( 1270 -**AT+FDR** 1271 -))) 1230 +* (% style="color:#037691" %)**AT+FDR** 1231 +* (% style="color:#037691" %)**AT+NJM=0** 1232 +* (% style="color:#037691" %)**ATZ** 1272 1272 1273 -(% class="box infomessage" %) 1274 1274 ((( 1275 -**AT+NJM=0** 1276 -))) 1277 - 1278 -(% class="box infomessage" %) 1279 -((( 1280 -**ATZ** 1281 -))) 1282 - 1283 - 1284 -((( 1285 1285 If device already joined network: 1286 -))) 1287 1287 1288 -(% class="box infomessage" %) 1289 -((( 1290 -**AT+NJM=0** 1291 -))) 1237 +* (% style="color:#037691" %)**AT+NJM=0** 1238 +* (% style="color:#037691" %)**ATZ** 1292 1292 1293 -(% class="box infomessage" %) 1294 -((( 1295 -**ATZ** 1240 + 1296 1296 ))) 1297 1297 1298 1298 ... ... @@ -1299,25 +1299,25 @@ 1299 1299 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1300 1300 1301 1301 1302 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1247 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1303 1303 1304 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1249 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode 1305 1305 1306 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1251 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off 1307 1307 1308 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1253 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) Set Data Rate 1309 1309 1310 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1255 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1311 1311 1312 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1257 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1313 1313 1314 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1259 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1315 1315 1316 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1261 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1317 1317 1318 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1263 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1319 1319 1320 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1265 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1321 1321 1322 1322 1323 1323 (% style="color:red" %)**Note:** ... ... @@ -1437,6 +1437,8 @@ 1437 1437 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1438 1438 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1439 1439 1385 + 1386 + 1440 1440 = 9.Packing Info = 1441 1441 1442 1442 ... ... @@ -1453,6 +1453,8 @@ 1453 1453 * Package Size / pcs : 14.5 x 8 x 5 cm 1454 1454 * Weight / pcs : 170g 1455 1455 1403 + 1404 + 1456 1456 = 10. FCC Caution for RS485LN-US915 = 1457 1457 1458 1458 (((