Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -134,6 +134,9 @@ 134 134 * Smart Cities 135 135 * Smart Factory 136 136 137 + 138 + 139 + 137 137 == 1.5 Firmware Change log == 138 138 139 139 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -582,7 +582,7 @@ 582 582 583 583 584 584 585 -==== (% style="color:#037691" %) **RS485 Debug Command**(%%) ====588 +==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ==== 586 586 587 587 ((( 588 588 This command is used to configure the RS485 devices; they won’t be used during sampling. ... ... @@ -589,7 +589,7 @@ 589 589 ))) 590 590 591 591 * ((( 592 -(% style="color:#037691" %) **AT Command**595 +**(% style="color:#037691" %)AT Command** 593 593 594 594 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 595 595 ... ... @@ -700,7 +700,7 @@ 700 700 701 701 702 702 703 -==== **Set Payload version** ==== 706 +==== **(% style="color:blue" %)Set Payload version** ==== 704 704 705 705 ((( 706 706 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -707,7 +707,7 @@ 707 707 ))) 708 708 709 709 * ((( 710 -**AT Command:** 713 +**(% style="color:#037691" %)AT Command:** 711 711 ))) 712 712 713 713 (% class="box infomessage" %) ... ... @@ -718,7 +718,7 @@ 718 718 ))) 719 719 720 720 * ((( 721 -**Downlink Payload:** 724 +**(% style="color:#037691" %)Downlink Payload:** 722 722 ))) 723 723 724 724 ((( ... ... @@ -732,7 +732,7 @@ 732 732 733 733 734 734 735 -==== **Set RS485 Sampling Commands** ==== 738 +==== **(% style="color:blue" %)Set RS485 Sampling Commands** ==== 736 736 737 737 ((( 738 738 AT+COMMANDx or AT+DATACUTx ... ... @@ -747,29 +747,18 @@ 747 747 ))) 748 748 749 749 * ((( 750 -**AT Command:** 753 +**(% style="color:#037691" %)AT Command:** 751 751 ))) 752 752 753 -(% class="box infomessage" %) 754 -((( 755 -((( 756 + 756 756 **AT+COMMANDx: Configure RS485 read command to sensor.** 757 -))) 758 -))) 759 759 760 -(% class="box infomessage" %) 761 -((( 762 -((( 759 + 763 763 **AT+DATACUTx: Configure how to handle return from RS485 devices.** 764 -))) 765 -))) 766 766 767 -((( 768 - 769 -))) 770 770 771 771 * ((( 772 -**Downlink Payload:** 764 +**(% style="color:#037691" %)Downlink Payload:** 773 773 ))) 774 774 775 775 ((( ... ... @@ -823,7 +823,7 @@ 823 823 824 824 825 825 826 -==== **Fast command to handle MODBUS device** ==== 818 +==== **(% style="color:blue" %)Fast command to handle MODBUS device** ==== 827 827 828 828 ((( 829 829 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. ... ... @@ -862,7 +862,7 @@ 862 862 863 863 864 864 865 -==== **RS485 command timeout** ==== 857 +==== **(% style="color:blue" %)RS485 command timeout** ==== 866 866 867 867 ((( 868 868 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. ... ... @@ -918,7 +918,7 @@ 918 918 919 919 920 920 921 -==== **Uplink payload mode** ==== 913 +==== **(% style="color:blue" %)Uplink payload mode** ==== 922 922 923 923 ((( 924 924 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -965,7 +965,7 @@ 965 965 966 966 967 967 968 -==== **Manually trigger an Uplink** ==== 960 +==== **(% style="color:blue" %)Manually trigger an Uplink** ==== 969 969 970 970 ((( 971 971 Ask device to send an uplink immediately.