From version < 61.9 >
edited by Xiaoling
on 2022/06/14 11:41
To version < 61.12 >
edited by Xiaoling
on 2022/06/14 11:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -134,6 +134,9 @@
134 134  * Smart Cities
135 135  * Smart Factory
136 136  
137 +
138 +
139 +
137 137  == 1.5 Firmware Change log ==
138 138  
139 139  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -582,7 +582,7 @@
582 582  
583 583  
584 584  
585 -==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ====
588 +==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====
586 586  
587 587  (((
588 588  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -589,7 +589,7 @@
589 589  )))
590 590  
591 591  * (((
592 -(% style="color:#037691" %)**AT Command**
595 +**(% style="color:#037691" %)AT Command**
593 593  
594 594  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
595 595  
... ... @@ -700,7 +700,7 @@
700 700  
701 701  
702 702  
703 -==== **Set Payload version** ====
706 +==== **(% style="color:blue" %)Set Payload version** ====
704 704  
705 705  (((
706 706  This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
... ... @@ -707,7 +707,7 @@
707 707  )))
708 708  
709 709  * (((
710 -**AT Command:**
713 +**(% style="color:#037691" %)AT Command:**
711 711  )))
712 712  
713 713  (% class="box infomessage" %)
... ... @@ -718,7 +718,7 @@
718 718  )))
719 719  
720 720  * (((
721 -**Downlink Payload:**
724 +**(% style="color:#037691" %)Downlink Payload:**
722 722  )))
723 723  
724 724  (((
... ... @@ -732,7 +732,7 @@
732 732  
733 733  
734 734  
735 -==== **Set RS485 Sampling Commands** ====
738 +==== **(% style="color:blue" %)Set RS485 Sampling Commands** ====
736 736  
737 737  (((
738 738  AT+COMMANDx or AT+DATACUTx
... ... @@ -747,29 +747,18 @@
747 747  )))
748 748  
749 749  * (((
750 -**AT Command:**
753 +**(% style="color:#037691" %)AT Command:**
751 751  )))
752 752  
753 -(% class="box infomessage" %)
754 -(((
755 -(((
756 +
756 756  **AT+COMMANDx: Configure RS485 read command to sensor.**
757 -)))
758 -)))
759 759  
760 -(% class="box infomessage" %)
761 -(((
762 -(((
759 +
763 763  **AT+DATACUTx: Configure how to handle return from RS485 devices.**
764 -)))
765 -)))
766 766  
767 -(((
768 -
769 -)))
770 770  
771 771  * (((
772 -**Downlink Payload:**
764 +**(% style="color:#037691" %)Downlink Payload:**
773 773  )))
774 774  
775 775  (((
... ... @@ -823,7 +823,7 @@
823 823  
824 824  
825 825  
826 -==== **Fast command to handle MODBUS device** ====
818 +==== **(% style="color:blue" %)Fast command to handle MODBUS device** ====
827 827  
828 828  (((
829 829  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].