<
From version < 61.8 >
edited by Xiaoling
on 2022/06/14 11:41
To version < 61.12 >
edited by Xiaoling
on 2022/06/14 11:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -122,6 +122,9 @@
122 122  * Support Modbus protocol
123 123  * Support Interrupt uplink (Since hardware version v1.2)
124 124  
125 +
126 +
127 +
125 125  == 1.4 Applications ==
126 126  
127 127  * Smart Buildings & Home Automation
... ... @@ -131,6 +131,9 @@
131 131  * Smart Cities
132 132  * Smart Factory
133 133  
137 +
138 +
139 +
134 134  == 1.5 Firmware Change log ==
135 135  
136 136  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -579,7 +579,7 @@
579 579  
580 580  
581 581  
582 -==== (% style="color:#037691" %)**RS485 Debug Command**(%%) ====
588 +==== **(% style="color:#037691" %)RS485 Debug Command**(%%) ====
583 583  
584 584  (((
585 585  This command is used to configure the RS485 devices; they won’t be used during sampling.
... ... @@ -586,7 +586,7 @@
586 586  )))
587 587  
588 588  * (((
589 -(% style="color:#037691" %)**AT Command**
595 +**(% style="color:#037691" %)AT Command**
590 590  
591 591  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
592 592  
... ... @@ -697,7 +697,7 @@
697 697  
698 698  
699 699  
700 -==== **Set Payload version** ====
706 +==== **(% style="color:blue" %)Set Payload version** ====
701 701  
702 702  (((
703 703  This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
... ... @@ -704,7 +704,7 @@
704 704  )))
705 705  
706 706  * (((
707 -**AT Command:**
713 +**(% style="color:#037691" %)AT Command:**
708 708  )))
709 709  
710 710  (% class="box infomessage" %)
... ... @@ -715,7 +715,7 @@
715 715  )))
716 716  
717 717  * (((
718 -**Downlink Payload:**
724 +**(% style="color:#037691" %)Downlink Payload:**
719 719  )))
720 720  
721 721  (((
... ... @@ -729,7 +729,7 @@
729 729  
730 730  
731 731  
732 -==== **Set RS485 Sampling Commands** ====
738 +==== **(% style="color:blue" %)Set RS485 Sampling Commands** ====
733 733  
734 734  (((
735 735  AT+COMMANDx or AT+DATACUTx
... ... @@ -744,29 +744,18 @@
744 744  )))
745 745  
746 746  * (((
747 -**AT Command:**
753 +**(% style="color:#037691" %)AT Command:**
748 748  )))
749 749  
750 -(% class="box infomessage" %)
751 -(((
752 -(((
756 +
753 753  **AT+COMMANDx: Configure RS485 read command to sensor.**
754 -)))
755 -)))
756 756  
757 -(% class="box infomessage" %)
758 -(((
759 -(((
759 +
760 760  **AT+DATACUTx: Configure how to handle return from RS485 devices.**
761 -)))
762 -)))
763 763  
764 -(((
765 -
766 -)))
767 767  
768 768  * (((
769 -**Downlink Payload:**
764 +**(% style="color:#037691" %)Downlink Payload:**
770 770  )))
771 771  
772 772  (((
... ... @@ -820,7 +820,7 @@
820 820  
821 821  
822 822  
823 -==== **Fast command to handle MODBUS device** ====
818 +==== **(% style="color:blue" %)Fast command to handle MODBUS device** ====
824 824  
825 825  (((
826 826  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0