Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,18 +12,72 @@ 12 12 13 13 14 14 15 - 16 - 17 - 18 - 19 - 20 20 **Table of Contents:** 21 21 22 -{{toc/}} 23 - 24 - 25 25 (% aria-label="macro:toc widget" contenteditable="false" role="region" tabindex="-1" %) 26 26 ((( 19 +(% class="macro" data-macro="startmacro:toc|-|" data-widget="xwiki-macro" %) 20 +((( 21 +(% class="macro-placeholder hidden" %) 22 +((( 23 +macro:toc 24 +))) 25 + 26 +* [[1.Introduction>>doc:null||anchor="H1.Introduction"]] 27 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>doc:null||anchor="H1.1A0WhatisRS485-LNRS485toLoRaWANConverter"]] 28 +** [[1.2 Specifications>>doc:null||anchor="H1.2A0Specifications"]] 29 +** [[1.3 Features>>doc:null||anchor="H1.3Features"]] 30 +** [[1.4 Applications>>doc:null||anchor="H1.4A0Applications"]] 31 +** [[1.5 Firmware Change log>>doc:null||anchor="H1.5A0FirmwareChangelog"]] 32 +** [[1.6 Hardware Change log>>doc:null||anchor="H1.6HardwareChangelog"]] 33 +* [[2. Power ON Device>>doc:null||anchor="H2.PowerONDevice"]] 34 +* [[3. Operation Mode>>doc:null||anchor="H3.A0OperationMode"]] 35 +** [[3.1 How it works?>>doc:null||anchor="H3.1Howitworks3F"]] 36 +** [[3.2 Example to join LoRaWAN network>>doc:null||anchor="H3.2ExampletojoinLoRaWANnetwork"]] 37 +** [[3.3 Configure Commands to read data>>doc:null||anchor="H3.3ConfigureCommandstoreaddata"]] 38 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>doc:null||anchor="H3.3.1onfigureUARTsettingsforRS485orTTLcommunication"]] 39 +*** [[3.3.2 Configure sensors>>doc:null||anchor="H3.3.2Configuresensors"]] 40 +*** [[3.3.3 Configure read commands for each sampling>>doc:null||anchor="H3.3.3Configurereadcommandsforeachsampling"]] 41 +*** [[3.3.4 Compose the uplink payload>>doc:null||anchor="H3.3.4Composetheuplinkpayload"]] 42 +*** [[3.3.5 Uplink on demand>>doc:null||anchor="H3.3.5Uplinkondemand"]] 43 +*** [[3.3.6 Uplink on Interrupt>>doc:null||anchor="H3.3.6UplinkonInterrupt"]] 44 +** [[3.4 Uplink Payload>>doc:null||anchor="H3.4UplinkPayload"]] 45 +** [[3.5 Configure RS485-LN via AT or Downlink>>doc:null||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] 46 +*** [[3.5.1 Common Commands>>doc:null||anchor="H3.5.1CommonCommands"]] 47 +*** [[3.5.2 Sensor related commands>>doc:null||anchor="H3.5.2Sensorrelatedcommands"]] 48 +*** [[3.5.3 Sensor related commands>>doc:null||anchor="H3.5.3A0Sensorrelatedcommands"]] 49 +**** [[RS485 Debug Command>>doc:null||anchor="HRS485DebugCommand"]] 50 +**** [[Set Payload version>>doc:null||anchor="HSetPayloadversion"]] 51 +**** [[Set RS485 Sampling Commands>>doc:null||anchor="HSetRS485SamplingCommands"]] 52 +**** [[Fast command to handle MODBUS device>>doc:null||anchor="HFastcommandtohandleMODBUSdevice"]] 53 +**** [[RS485 command timeout>>doc:null||anchor="HRS485commandtimeout"]] 54 +**** [[Uplink payload mode>>doc:null||anchor="HUplinkpayloadmode"]] 55 +**** [[Manually trigger an Uplink>>doc:null||anchor="HManuallytriggeranUplink"]] 56 +**** [[Clear RS485 Command>>doc:null||anchor="HClearRS485Command"]] 57 +**** [[Set Serial Communication Parameters>>doc:null||anchor="HSetSerialCommunicationParameters"]] 58 +** [[3.6 Listening mode for RS485 network>>doc:null||anchor="H3.6A0ListeningmodeforRS485network"]] 59 +** [[3.7 Buttons>>doc:null||anchor="H3.7Buttons"]] 60 +** [[3.8 LEDs>>doc:null||anchor="H3.8LEDs"]] 61 +* [[4. Case Study>>doc:null||anchor="H4.CaseStudy"]] 62 +* [[5. Use AT Command>>doc:null||anchor="H5.UseATCommand"]] 63 +** [[5.1 Access AT Command>>doc:null||anchor="H5.1AccessATCommand"]] 64 +** [[5.2 Common AT Command Sequence>>doc:null||anchor="H5.2CommonATCommandSequence"]] 65 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>doc:null||anchor="H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829"]] 66 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>doc:null||anchor="H5.5.2Single-channelABPmode28UsewithLG012FLG0229"]] 67 +* [[6. FAQ>>doc:null||anchor="H6.FAQ"]] 68 +** [[6.1 How to upgrade the image?>>doc:null||anchor="H6.1Howtoupgradetheimage3F"]] 69 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>doc:null||anchor="H6.2HowtochangetheLoRaFrequencyBands2FRegion3F"]] 70 +** [[6.3 How many RS485-Slave can RS485-LN connects?>>doc:null||anchor="H6.3HowmanyRS485-SlavecanRS485-LNconnects3F"]] 71 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>doc:null||anchor="H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F"]] 72 +* [[7. Trouble Shooting>>doc:null||anchor="H7.TroubleShooting"]] 73 +** [[7.1 Downlink doesn’t work, how to solve it?>>doc:null||anchor="H7.1Downlinkdoesn2019twork2Chowtosolveit3F"]] 74 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>doc:null||anchor="H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F"]] 75 +* [[8. Order Info>>doc:null||anchor="H8.OrderInfo"]] 76 +* [[9.Packing Info>>doc:null||anchor="H9.PackingInfo"]] 77 +* [[10. FCC Caution for RS485LN-US915>>doc:null||anchor="H10.FCCCautionforRS485LN-US915"]] 78 +* [[11. Support>>doc:null||anchor="H11.Support"]] 79 +))) 80 + 27 27 (% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||height="15" role="presentation" title="Click and drag to move" width="15"]] 28 28 ))) 29 29 ... ... @@ -337,7 +337,6 @@ 337 337 338 338 339 339 340 - 341 341 === 3.3.2 Configure sensors === 342 342 343 343 ((( ... ... @@ -364,8 +364,6 @@ 364 364 365 365 366 366 367 - 368 - 369 369 === 3.3.3 Configure read commands for each sampling === 370 370 371 371 ((( ... ... @@ -596,13 +596,13 @@ 596 596 * ((( 597 597 (% style="color:#037691" %)**AT Command** 598 598 599 -((( 600 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 650 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 651 + 652 + 601 601 ))) 602 -))) 603 603 604 604 ((( 605 - 656 +m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 606 606 ))) 607 607 608 608 * ((( ... ... @@ -643,9 +643,7 @@ 643 643 ))) 644 644 645 645 ((( 646 - 647 - 648 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 697 +**Example 1** ~-~-> Configure without ask for uplink (YY=0) 649 649 ))) 650 650 651 651 ((( ... ... @@ -661,8 +661,6 @@ 661 661 ))) 662 662 663 663 ((( 664 - 665 - 666 666 So if user want to use downlink command to control to RS485 Alarm, he can use: 667 667 ))) 668 668 ... ... @@ -683,7 +683,7 @@ 683 683 ))) 684 684 685 685 ((( 686 -**Example 2** 733 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 687 687 ))) 688 688 689 689 ((( ... ... @@ -695,11 +695,11 @@ 695 695 ))) 696 696 697 697 ((( 698 -((( 699 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 745 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 700 700 ))) 701 701 702 - 748 +((( 749 + **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 703 703 ))) 704 704 705 705 ((( ... ... @@ -709,7 +709,7 @@ 709 709 710 710 711 711 712 -==== (% style="color:blue" %)**Set Payload version**(%%)====759 +==== **Set Payload version** ==== 713 713 714 714 ((( 715 715 This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -716,28 +716,32 @@ 716 716 ))) 717 717 718 718 * ((( 719 -(% style="color:#037691" %)**AT Command:** 766 +**AT Command:** 767 +))) 720 720 721 -**AT+PAYVER: **Set PAYVER field = 1 722 - 723 - 769 +(% class="box infomessage" %) 770 +((( 771 +((( 772 +**AT+PAYVER: Set PAYVER field = 1** 724 724 ))) 774 +))) 775 + 725 725 * ((( 726 - (% style="color:#037691" %)**Downlink Payload:**777 +**Downlink Payload:** 727 727 ))) 728 728 729 729 ((( 730 -**0xAE 01** ~-~-> 781 +**0xAE 01** ~-~-> Set PAYVER field = 0x01 731 731 ))) 732 732 733 733 ((( 734 -**0xAE 0F** ~-~-> 785 +**0xAE 0F** ~-~-> Set PAYVER field = 0x0F 735 735 ))) 736 736 737 737 738 738 739 739 740 -==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%)====791 +==== **Set RS485 Sampling Commands** ==== 741 741 742 742 ((( 743 743 AT+COMMANDx or AT+DATACUTx ... ... @@ -752,16 +752,29 @@ 752 752 ))) 753 753 754 754 * ((( 755 - (% style="color:#037691" %)**AT Command:**806 +**AT Command:** 756 756 ))) 757 757 758 -**AT+COMMANDx: **Configure RS485 read command to sensor. 809 +(% class="box infomessage" %) 810 +((( 811 +((( 812 +**AT+COMMANDx: Configure RS485 read command to sensor.** 813 +))) 814 +))) 759 759 760 -**AT+DATACUTx: **Configure how to handle return from RS485 devices. 816 +(% class="box infomessage" %) 817 +((( 818 +((( 819 +**AT+DATACUTx: Configure how to handle return from RS485 devices.** 820 +))) 821 +))) 761 761 823 +((( 824 + 825 +))) 762 762 763 763 * ((( 764 - (% style="color:#037691" %)**Downlink Payload:**828 +**Downlink Payload:** 765 765 ))) 766 766 767 767 ((( ... ... @@ -797,8 +797,6 @@ 797 797 ))) 798 798 799 799 ((( 800 - 801 - 802 802 **Example:** 803 803 ))) 804 804 ... ... @@ -817,10 +817,10 @@ 817 817 818 818 819 819 820 -==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%)====882 +==== **Fast command to handle MODBUS device** ==== 821 821 822 822 ((( 823 - **AT+MBFUN**is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].885 +AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 824 824 ))) 825 825 826 826 ((( ... ... @@ -840,25 +840,23 @@ 840 840 ))) 841 841 842 842 * ((( 843 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 905 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 844 844 ))) 845 845 * ((( 846 -AT+COMMAND1= 01 03 00 10 00 08,1 908 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 847 847 ))) 848 848 * ((( 849 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 850 - 851 - 911 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 852 852 ))) 853 853 854 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %) 914 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 855 855 856 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %) 916 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 857 857 858 858 859 859 860 860 861 -==== (% style="color:blue" %)**RS485 command timeout**(%%)====921 +==== **RS485 command timeout** ==== 862 862 863 863 ((( 864 864 Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. ... ... @@ -869,14 +869,17 @@ 869 869 ))) 870 870 871 871 * ((( 872 -(% style="color:#037691" %)** AT Command:** 932 +**AT Command:** 933 +))) 873 873 935 +(% class="box infomessage" %) 936 +((( 937 +((( 874 874 **AT+CMDDLaa=hex(bb cc)*1000** 875 875 ))) 940 +))) 876 876 877 877 ((( 878 - 879 - 880 880 **Example:** 881 881 ))) 882 882 ... ... @@ -889,7 +889,7 @@ 889 889 ))) 890 890 891 891 * ((( 892 - (% style="color:#037691" %)**955 +**Downlink Payload:** 893 893 ))) 894 894 895 895 ((( ... ... @@ -901,17 +901,17 @@ 901 901 ))) 902 902 903 903 ((( 904 -**Example:** 967 + **Example:** 905 905 ))) 906 906 907 907 ((( 908 - **0xAA 01 00 01**971 + 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 909 909 ))) 910 910 911 911 912 912 913 913 914 -==== (% style="color:blue" %)**Uplink payload mode**(%%)====977 +==== **Uplink payload mode** ==== 915 915 916 916 ((( 917 917 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -919,21 +919,32 @@ 919 919 920 920 ((( 921 921 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 922 - 923 - 924 924 ))) 925 925 926 926 * ((( 927 - (% style="color:#037691" %)**988 +**AT Command:** 928 928 ))) 929 929 991 +(% class="box infomessage" %) 992 +((( 993 +((( 930 930 **AT+DATAUP=0** 995 +))) 996 +))) 931 931 998 +(% class="box infomessage" %) 999 +((( 1000 +((( 932 932 **AT+DATAUP=1** 1002 +))) 1003 +))) 933 933 1005 +((( 1006 + 1007 +))) 934 934 935 935 * ((( 936 - (% style="color:#037691" %)**1010 +**Downlink Payload:** 937 937 ))) 938 938 939 939 ((( ... ... @@ -947,7 +947,7 @@ 947 947 948 948 949 949 950 -==== (% style="color:blue" %)**Manually trigger an Uplink**(%%)====1024 +==== **Manually trigger an Uplink** ==== 951 951 952 952 ((( 953 953 Ask device to send an uplink immediately. ... ... @@ -954,7 +954,7 @@ 954 954 ))) 955 955 956 956 * ((( 957 - (% style="color:#037691" %)**1031 +**AT Command:** 958 958 ))) 959 959 960 960 ((( ... ... @@ -966,7 +966,7 @@ 966 966 ))) 967 967 968 968 * ((( 969 - (% style="color:#037691" %)**1043 +**Downlink Payload:** 970 970 ))) 971 971 972 972 ((( ... ... @@ -976,16 +976,14 @@ 976 976 977 977 978 978 979 -==== (% style="color:blue" %)**Clear RS485 Command**(%%)====1053 +==== **Clear RS485 Command** ==== 980 980 981 981 ((( 982 982 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 983 - 984 - 985 985 ))) 986 986 987 987 * ((( 988 - (% style="color:#037691" %)**1060 +**AT Command:** 989 989 ))) 990 990 991 991 ((( ... ... @@ -1012,7 +1012,7 @@ 1012 1012 1013 1013 1014 1014 * ((( 1015 - (% style="color:#037691" %)**1087 +**Downlink Payload:** 1016 1016 ))) 1017 1017 1018 1018 ((( ... ... @@ -1022,7 +1022,7 @@ 1022 1022 1023 1023 1024 1024 1025 -==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%)====1097 +==== **Set Serial Communication Parameters** ==== 1026 1026 1027 1027 ((( 1028 1028 Set the Rs485 serial communication parameters: ... ... @@ -1029,39 +1029,52 @@ 1029 1029 ))) 1030 1030 1031 1031 * ((( 1032 - (% style="color:#037691" %)**1104 +**AT Command:** 1033 1033 ))) 1034 1034 1035 1035 ((( 1036 - 1037 - 1038 -* Set Baud Rate 1108 +Set Baud Rate: 1039 1039 ))) 1040 1040 1111 +(% class="box infomessage" %) 1112 +((( 1113 +((( 1041 1041 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1115 +))) 1116 +))) 1042 1042 1043 - 1044 1044 ((( 1045 - *Set UART Parity1119 +Set UART Parity 1046 1046 ))) 1047 1047 1122 +(% class="box infomessage" %) 1123 +((( 1124 +((( 1048 1048 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1126 +))) 1127 +))) 1049 1049 1050 - 1051 1051 ((( 1052 - *Set STOPBIT1130 +Set STOPBIT 1053 1053 ))) 1054 1054 1133 +(% class="box infomessage" %) 1134 +((( 1135 +((( 1055 1055 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1137 +))) 1138 +))) 1056 1056 1140 +((( 1141 + 1142 +))) 1057 1057 1058 - 1059 1059 * ((( 1060 - (% style="color:#037691" %)**1145 +**Downlink Payload:** 1061 1061 ))) 1062 1062 1063 1063 ((( 1064 -**A7 01 aa bb**: 1149 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1065 1065 ))) 1066 1066 1067 1067 ((( ... ... @@ -1076,11 +1076,11 @@ 1076 1076 ))) 1077 1077 1078 1078 ((( 1079 -A7 02 aa: 1164 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1080 1080 ))) 1081 1081 1082 1082 ((( 1083 -A7 03 aa: 1168 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1084 1084 ))) 1085 1085 1086 1086 ... ... @@ -1134,7 +1134,7 @@ 1134 1134 ))) 1135 1135 1136 1136 ((( 1137 - (% style="color:#037691" %)**1222 +**Downlink Command:** 1138 1138 ))) 1139 1139 1140 1140 ((( ... ... @@ -1193,9 +1193,6 @@ 1193 1193 |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1194 1194 |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1195 1195 1196 - 1197 - 1198 - 1199 1199 == 3.8 LEDs == 1200 1200 1201 1201 ... ... @@ -1204,9 +1204,6 @@ 1204 1204 |**PWR**|Always on if there is power 1205 1205 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1206 1206 1207 - 1208 - 1209 - 1210 1210 = 4. Case Study = 1211 1211 1212 1212 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1238,24 +1238,38 @@ 1238 1238 1239 1239 == 5.2 Common AT Command Sequence == 1240 1240 1241 - 1242 1242 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1243 1243 1244 1244 If device has not joined network yet: 1245 1245 1246 -* (% style="color:#037691" %)**AT+FDR** 1247 -* (% style="color:#037691" %)**AT+NJM=0** 1248 -* (% style="color:#037691" %)**ATZ** 1324 +(% class="box infomessage" %) 1325 +((( 1326 +**AT+FDR** 1327 +))) 1249 1249 1329 +(% class="box infomessage" %) 1250 1250 ((( 1251 - 1331 +**AT+NJM=0** 1332 +))) 1252 1252 1334 +(% class="box infomessage" %) 1335 +((( 1336 +**ATZ** 1337 +))) 1338 + 1339 + 1340 +((( 1253 1253 If device already joined network: 1342 +))) 1254 1254 1255 -* (% style="color:#037691" %)**AT+NJM=0** 1256 -* (% style="color:#037691" %)**ATZ** 1344 +(% class="box infomessage" %) 1345 +((( 1346 +**AT+NJM=0** 1347 +))) 1257 1257 1258 - 1349 +(% class="box infomessage" %) 1350 +((( 1351 +**ATZ** 1259 1259 ))) 1260 1260 1261 1261 ... ... @@ -1262,25 +1262,25 @@ 1262 1262 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1263 1263 1264 1264 1265 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) 1358 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1266 1266 1267 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) 1360 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1268 1268 1269 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) 1362 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1270 1270 1271 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) 1364 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1272 1272 1273 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) 1366 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1274 1274 1275 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) 1368 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1276 1276 1277 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) 1370 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1278 1278 1279 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) 1372 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1280 1280 1281 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 1374 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1282 1282 1283 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) 1376 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1284 1284 1285 1285 1286 1286 (% style="color:red" %)**Note:** ... ... @@ -1320,15 +1320,15 @@ 1320 1320 (% aria-label="1654162535040-878.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654162535040-878.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1321 1321 1322 1322 ((( 1323 -** (% style="color:blue" %)Step1(%%):** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].1416 +**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1324 1324 ))) 1325 1325 1326 1326 ((( 1327 -** (% style="color:blue" %)Step2(%%):** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].1420 +**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1328 1328 ))) 1329 1329 1330 1330 ((( 1331 -** (% style="color:blue" %)Step3(%%): **Open flashloader; choose the correct COM port to update.1424 +**Step3: **Open flashloader; choose the correct COM port to update. 1332 1332 ))) 1333 1333 1334 1334 ((( ... ... @@ -1349,7 +1349,7 @@ 1349 1349 (% aria-label="image-20220602175912-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175912-14.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1350 1350 1351 1351 1352 -** (% style="color:red" %)Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:1445 +**Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1353 1353 1354 1354 (% aria-label="image-20220602175638-10.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602175638-10.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 1355 1355 ... ... @@ -1389,20 +1389,17 @@ 1389 1389 1390 1390 (% style="color:blue" %)**XXX:** 1391 1391 1392 -* (% style="color: red" %)**EU433**(%%): frequency bands EU4331393 -* (% style="color: red" %)**EU868**(%%): frequency bands EU8681394 -* (% style="color: red" %)**KR920**(%%): frequency bands KR9201395 -* (% style="color: red" %)**CN470**(%%): frequency bands CN4701396 -* (% style="color: red" %)**AS923**(%%): frequency bands AS9231397 -* (% style="color: red" %)**AU915**(%%): frequency bands AU9151398 -* (% style="color: red" %)**US915**(%%): frequency bands US9151399 -* (% style="color: red" %)**IN865**(%%): frequency bands IN8651400 -* (% style="color: red" %)**RU864**(%%): frequency bands RU8641401 -* (% style="color: red" %)**KZ865**(%%): frequency bands KZ8651485 +* (% style="color:blue" %)**EU433**(%%): frequency bands EU433 1486 +* (% style="color:blue" %)**EU868**(%%): frequency bands EU868 1487 +* (% style="color:blue" %)**KR920**(%%): frequency bands KR920 1488 +* (% style="color:blue" %)**CN470**(%%): frequency bands CN470 1489 +* (% style="color:blue" %)**AS923**(%%): frequency bands AS923 1490 +* (% style="color:blue" %)**AU915**(%%): frequency bands AU915 1491 +* (% style="color:blue" %)**US915**(%%): frequency bands US915 1492 +* (% style="color:blue" %)**IN865**(%%): frequency bands IN865 1493 +* (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1494 +* (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1402 1402 1403 - 1404 - 1405 - 1406 1406 = 9.Packing Info = 1407 1407 1408 1408 ... ... @@ -1419,9 +1419,6 @@ 1419 1419 * Package Size / pcs : 14.5 x 8 x 5 cm 1420 1420 * Weight / pcs : 170g 1421 1421 1422 - 1423 - 1424 - 1425 1425 = 10. FCC Caution for RS485LN-US915 = 1426 1426 1427 1427 (((