From version < 61.44 >
edited by Xiaoling
on 2022/06/25 15:57
To version < 61.30 >
edited by Xiaoling
on 2022/06/14 11:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,11 +12,6 @@
12 12  
13 13  
14 14  
15 -
16 -
17 -
18 -
19 -
20 20  **Table of Contents:**
21 21  
22 22  {{toc/}}
... ... @@ -112,6 +112,7 @@
112 112  * Packet engine up to 256 bytes with CRC
113 113  
114 114  
110 +
115 115  == 1.3 Features ==
116 116  
117 117  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -124,6 +124,7 @@
124 124  * Support Interrupt uplink (Since hardware version v1.2)
125 125  
126 126  
123 +
127 127  == 1.4 Applications ==
128 128  
129 129  * Smart Buildings & Home Automation
... ... @@ -134,6 +134,7 @@
134 134  * Smart Factory
135 135  
136 136  
134 +
137 137  == 1.5 Firmware Change log ==
138 138  
139 139  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -365,7 +365,6 @@
365 365  
366 366  
367 367  
368 -
369 369  === 3.3.3 Configure read commands for each sampling ===
370 370  
371 371  (((
... ... @@ -718,7 +718,7 @@
718 718  * (((
719 719  (% style="color:#037691" %)**AT Command:**
720 720  
721 -**AT+PAYVER:    **Set PAYVER field = 1
718 +**AT+PAYVER:  **Set PAYVER field = 1
722 722  
723 723  
724 724  )))
... ... @@ -755,9 +755,9 @@
755 755  (% style="color:#037691" %)**AT Command:**
756 756  )))
757 757  
758 -**AT+COMMANDx:    **Configure RS485 read command to sensor.
755 +**AT+COMMANDx:  **Configure RS485 read command to sensor.
759 759  
760 -**AT+DATACUTx:        **Configure how to handle return from RS485 devices.
757 +**AT+DATACUTx:  **Configure how to handle return from RS485 devices.
761 761  
762 762  
763 763  * (((
... ... @@ -1061,7 +1061,7 @@
1061 1061  )))
1062 1062  
1063 1063  (((
1064 -**A7 01 aa bb**:  Same  AT+BAUDR=hex(aa bb)*100
1061 +**A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1065 1065  )))
1066 1066  
1067 1067  (((
... ... @@ -1076,11 +1076,11 @@
1076 1076  )))
1077 1077  
1078 1078  (((
1079 -A7 02 aa:  Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1076 +A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1080 1080  )))
1081 1081  
1082 1082  (((
1083 -A7 03 aa:  Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1080 +A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1084 1084  )))
1085 1085  
1086 1086  
... ... @@ -1134,7 +1134,7 @@
1134 1134  )))
1135 1135  
1136 1136  (((
1137 -(% style="color:#037691" %)** Downlink Command:**
1134 +**Downlink Command:**
1138 1138  )))
1139 1139  
1140 1140  (((
... ... @@ -1193,7 +1193,6 @@
1193 1193  |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1194 1194  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1195 1195  
1196 -
1197 1197  == 3.8 LEDs ==
1198 1198  
1199 1199  
... ... @@ -1202,7 +1202,6 @@
1202 1202  |**PWR**|Always on if there is power
1203 1203  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1204 1204  
1205 -
1206 1206  = 4. Case Study =
1207 1207  
1208 1208  User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
... ... @@ -1234,24 +1234,38 @@
1234 1234  
1235 1235  == 5.2 Common AT Command Sequence ==
1236 1236  
1237 -
1238 1238  === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1239 1239  
1240 1240  If device has not joined network yet:
1241 1241  
1242 -* (% style="color:#037691" %)**AT+FDR**
1243 -* (% style="color:#037691" %)**AT+NJM=0**
1244 -* (% style="color:#037691" %)**ATZ**
1236 +(% class="box infomessage" %)
1237 +(((
1238 +**AT+FDR**
1239 +)))
1245 1245  
1241 +(% class="box infomessage" %)
1246 1246  (((
1247 -
1243 +**AT+NJM=0**
1244 +)))
1248 1248  
1246 +(% class="box infomessage" %)
1247 +(((
1248 +**ATZ**
1249 +)))
1250 +
1251 +
1252 +(((
1249 1249  If device already joined network:
1254 +)))
1250 1250  
1251 -* (% style="color:#037691" %)**AT+NJM=0**
1252 -* (% style="color:#037691" %)**ATZ**
1256 +(% class="box infomessage" %)
1257 +(((
1258 +**AT+NJM=0**
1259 +)))
1253 1253  
1254 -
1261 +(% class="box infomessage" %)
1262 +(((
1263 +**ATZ**
1255 1255  )))
1256 1256  
1257 1257  
... ... @@ -1258,25 +1258,25 @@
1258 1258  === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) ===
1259 1259  
1260 1260  
1261 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1270 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve
1262 1262  
1263 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode
1272 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode
1264 1264  
1265 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off
1274 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off
1266 1266  
1267 -(% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%) Set Data Rate
1276 +(% style="background-color:#dcdcdc" %)**AT+DR=5**   (%%)Set Data Rate
1268 1268  
1269 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1278 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds
1270 1270  
1271 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%)  Set transmit frequency to 868.4Mhz
1280 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz
1272 1272  
1273 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1282 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server)
1274 1274  
1275 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1284 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5**  (%%) Set RX2DR to match the downlink DR from server. see below
1276 1276  
1277 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1286 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1278 1278  
1279 -(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1288 +(% style="background-color:#dcdcdc" %)**ATZ**       (%%) Reset MCU
1280 1280  
1281 1281  
1282 1282  (% style="color:red" %)**Note:**
... ... @@ -1396,7 +1396,6 @@
1396 1396  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1397 1397  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1398 1398  
1399 -
1400 1400  = 9.Packing Info =
1401 1401  
1402 1402  
... ... @@ -1413,7 +1413,6 @@
1413 1413  * Package Size / pcs : 14.5 x 8 x 5 cm
1414 1414  * Weight / pcs : 170g
1415 1415  
1416 -
1417 1417  = 10. FCC Caution for RS485LN-US915 =
1418 1418  
1419 1419  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0