Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,11 +12,6 @@ 12 12 13 13 14 14 15 - 16 - 17 - 18 - 19 - 20 20 **Table of Contents:** 21 21 22 22 {{toc/}} ... ... @@ -112,6 +112,7 @@ 112 112 * Packet engine up to 256 bytes with CRC 113 113 114 114 110 + 115 115 == 1.3 Features == 116 116 117 117 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -124,6 +124,7 @@ 124 124 * Support Interrupt uplink (Since hardware version v1.2) 125 125 126 126 123 + 127 127 == 1.4 Applications == 128 128 129 129 * Smart Buildings & Home Automation ... ... @@ -134,6 +134,7 @@ 134 134 * Smart Factory 135 135 136 136 134 + 137 137 == 1.5 Firmware Change log == 138 138 139 139 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -335,6 +335,9 @@ 335 335 ))) 336 336 ))) 337 337 336 + 337 + 338 + 338 338 === 3.3.2 Configure sensors === 339 339 340 340 ((( ... ... @@ -359,6 +359,9 @@ 359 359 ))) 360 360 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 361 361 363 + 364 + 365 + 362 362 === 3.3.3 Configure read commands for each sampling === 363 363 364 364 ((( ... ... @@ -711,7 +711,7 @@ 711 711 * ((( 712 712 (% style="color:#037691" %)**AT Command:** 713 713 714 -**AT+PAYVER: 718 +**AT+PAYVER: **Set PAYVER field = 1 715 715 716 716 717 717 ))) ... ... @@ -748,9 +748,9 @@ 748 748 (% style="color:#037691" %)**AT Command:** 749 749 ))) 750 750 751 -**AT+COMMANDx: 755 +**AT+COMMANDx: **Configure RS485 read command to sensor. 752 752 753 -**AT+DATACUTx: 757 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 754 754 755 755 756 756 * ((( ... ... @@ -912,8 +912,6 @@ 912 912 913 913 ((( 914 914 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 915 - 916 - 917 917 ))) 918 918 919 919 * ((( ... ... @@ -973,8 +973,6 @@ 973 973 974 974 ((( 975 975 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 976 - 977 - 978 978 ))) 979 979 980 980 * ((( ... ... @@ -1026,35 +1026,35 @@ 1026 1026 ))) 1027 1027 1028 1028 ((( 1029 - 1030 - 1031 -* Set Baud Rate 1029 +Set Baud Rate: 1032 1032 ))) 1033 1033 1032 + 1034 1034 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1035 1035 1036 1036 1037 1037 ((( 1038 - *Set UART Parity1037 +Set UART Parity 1039 1039 ))) 1040 1040 1040 + 1041 1041 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1042 1042 1043 1043 1044 1044 ((( 1045 - *Set STOPBIT1045 +Set STOPBIT 1046 1046 ))) 1047 1047 1048 + 1048 1048 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1049 1049 1050 1050 1051 - 1052 1052 * ((( 1053 1053 (% style="color:#037691" %)** Downlink Payload:** 1054 1054 ))) 1055 1055 1056 1056 ((( 1057 -**A7 01 aa bb**: 1057 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1058 1058 ))) 1059 1059 1060 1060 ((( ... ... @@ -1069,11 +1069,11 @@ 1069 1069 ))) 1070 1070 1071 1071 ((( 1072 -A7 02 aa: 1072 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1073 1073 ))) 1074 1074 1075 1075 ((( 1076 -A7 03 aa: 1076 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1077 1077 ))) 1078 1078 1079 1079 ... ... @@ -1127,7 +1127,7 @@ 1127 1127 ))) 1128 1128 1129 1129 ((( 1130 - (% style="color:#037691" %)**1130 +**Downlink Command:** 1131 1131 ))) 1132 1132 1133 1133 ((( ... ... @@ -1186,7 +1186,6 @@ 1186 1186 |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1187 1187 |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1188 1188 1189 - 1190 1190 == 3.8 LEDs == 1191 1191 1192 1192 ... ... @@ -1195,7 +1195,6 @@ 1195 1195 |**PWR**|Always on if there is power 1196 1196 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1197 1197 1198 - 1199 1199 = 4. Case Study = 1200 1200 1201 1201 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1227,24 +1227,38 @@ 1227 1227 1228 1228 == 5.2 Common AT Command Sequence == 1229 1229 1230 - 1231 1231 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1232 1232 1233 1233 If device has not joined network yet: 1234 1234 1235 -* (% style="color:#037691" %)**AT+FDR** 1236 -* (% style="color:#037691" %)**AT+NJM=0** 1237 -* (% style="color:#037691" %)**ATZ** 1232 +(% class="box infomessage" %) 1233 +((( 1234 +**AT+FDR** 1235 +))) 1238 1238 1237 +(% class="box infomessage" %) 1239 1239 ((( 1240 - 1239 +**AT+NJM=0** 1240 +))) 1241 1241 1242 +(% class="box infomessage" %) 1243 +((( 1244 +**ATZ** 1245 +))) 1246 + 1247 + 1248 +((( 1242 1242 If device already joined network: 1250 +))) 1243 1243 1244 -* (% style="color:#037691" %)**AT+NJM=0** 1245 -* (% style="color:#037691" %)**ATZ** 1252 +(% class="box infomessage" %) 1253 +((( 1254 +**AT+NJM=0** 1255 +))) 1246 1246 1247 - 1257 +(% class="box infomessage" %) 1258 +((( 1259 +**ATZ** 1248 1248 ))) 1249 1249 1250 1250 ... ... @@ -1251,25 +1251,25 @@ 1251 1251 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1252 1252 1253 1253 1254 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) 1266 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1255 1255 1256 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) 1268 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1257 1257 1258 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) 1270 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1259 1259 1260 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) 1272 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1261 1261 1262 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) 1274 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1263 1263 1264 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) 1276 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1265 1265 1266 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) 1278 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1267 1267 1268 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) 1280 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1269 1269 1270 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 1282 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1271 1271 1272 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) 1284 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1273 1273 1274 1274 1275 1275 (% style="color:red" %)**Note:** ... ... @@ -1389,7 +1389,6 @@ 1389 1389 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1390 1390 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1391 1391 1392 - 1393 1393 = 9.Packing Info = 1394 1394 1395 1395 ... ... @@ -1406,7 +1406,6 @@ 1406 1406 * Package Size / pcs : 14.5 x 8 x 5 cm 1407 1407 * Weight / pcs : 170g 1408 1408 1409 - 1410 1410 = 10. FCC Caution for RS485LN-US915 = 1411 1411 1412 1412 (((