Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -108,8 +108,6 @@ 108 108 109 109 110 110 111 - 112 - 113 113 == 1.3 Features == 114 114 115 115 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -123,8 +123,6 @@ 123 123 124 124 125 125 126 - 127 - 128 128 == 1.4 Applications == 129 129 130 130 * Smart Buildings & Home Automation ... ... @@ -136,8 +136,6 @@ 136 136 137 137 138 138 139 - 140 - 141 141 == 1.5 Firmware Change log == 142 142 143 143 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -340,6 +340,8 @@ 340 340 ))) 341 341 342 342 337 + 338 + 343 343 === 3.3.2 Configure sensors === 344 344 345 345 ((( ... ... @@ -365,6 +365,8 @@ 365 365 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 366 366 367 367 364 + 365 + 368 368 === 3.3.3 Configure read commands for each sampling === 369 369 370 370 ((( ... ... @@ -660,8 +660,6 @@ 660 660 ))) 661 661 662 662 ((( 663 - 664 - 665 665 So if user want to use downlink command to control to RS485 Alarm, he can use: 666 666 ))) 667 667 ... ... @@ -682,7 +682,7 @@ 682 682 ))) 683 683 684 684 ((( 685 -**Example 2** 681 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 686 686 ))) 687 687 688 688 ((( ... ... @@ -694,11 +694,11 @@ 694 694 ))) 695 695 696 696 ((( 697 -((( 698 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 693 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 699 699 ))) 700 700 701 - 696 +((( 697 + **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 702 702 ))) 703 703 704 704 ((( ... ... @@ -717,7 +717,7 @@ 717 717 * ((( 718 718 (% style="color:#037691" %)**AT Command:** 719 719 720 -**AT+PAYVER: 716 +**AT+PAYVER: **Set PAYVER field = 1 721 721 722 722 723 723 ))) ... ... @@ -754,9 +754,9 @@ 754 754 (% style="color:#037691" %)**AT Command:** 755 755 ))) 756 756 757 -**AT+COMMANDx: 753 +**AT+COMMANDx: **Configure RS485 read command to sensor. 758 758 759 -**AT+DATACUTx: 755 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 760 760 761 761 762 762 * ((( ... ... @@ -796,8 +796,6 @@ 796 796 ))) 797 797 798 798 ((( 799 - 800 - 801 801 **Example:** 802 802 ))) 803 803 ... ... @@ -819,7 +819,7 @@ 819 819 ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ==== 820 820 821 821 ((( 822 - **AT+MBFUN**is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].816 +AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 823 823 ))) 824 824 825 825 ((( ... ... @@ -839,20 +839,18 @@ 839 839 ))) 840 840 841 841 * ((( 842 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 836 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 843 843 ))) 844 844 * ((( 845 -AT+COMMAND1= 01 03 00 10 00 08,1 839 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 846 846 ))) 847 847 * ((( 848 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 849 - 850 - 842 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 851 851 ))) 852 852 853 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %) 845 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 854 854 855 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %) 847 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 856 856 857 857 858 858 ... ... @@ -869,13 +869,16 @@ 869 869 870 870 * ((( 871 871 (% style="color:#037691" %)** AT Command:** 864 +))) 872 872 866 +(% class="box infomessage" %) 867 +((( 868 +((( 873 873 **AT+CMDDLaa=hex(bb cc)*1000** 874 874 ))) 871 +))) 875 875 876 876 ((( 877 - 878 - 879 879 **Example:** 880 880 ))) 881 881 ... ... @@ -900,11 +900,11 @@ 900 900 ))) 901 901 902 902 ((( 903 -**Example:** 898 + **Example:** 904 904 ))) 905 905 906 906 ((( 907 - **0xAA 01 00 01**902 + 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 908 908 ))) 909 909 910 910 ... ... @@ -918,8 +918,6 @@ 918 918 919 919 ((( 920 920 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 921 - 922 - 923 923 ))) 924 924 925 925 * ((( ... ... @@ -979,8 +979,6 @@ 979 979 980 980 ((( 981 981 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 982 - 983 - 984 984 ))) 985 985 986 986 * ((( ... ... @@ -1032,35 +1032,35 @@ 1032 1032 ))) 1033 1033 1034 1034 ((( 1035 - 1036 - 1037 -* Set Baud Rate 1026 +Set Baud Rate: 1038 1038 ))) 1039 1039 1029 + 1040 1040 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1041 1041 1042 1042 1043 1043 ((( 1044 - *Set UART Parity1034 +Set UART Parity 1045 1045 ))) 1046 1046 1037 + 1047 1047 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1048 1048 1049 1049 1050 1050 ((( 1051 - *Set STOPBIT1042 +Set STOPBIT 1052 1052 ))) 1053 1053 1045 + 1054 1054 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1055 1055 1056 1056 1057 - 1058 1058 * ((( 1059 1059 (% style="color:#037691" %)** Downlink Payload:** 1060 1060 ))) 1061 1061 1062 1062 ((( 1063 -**A7 01 aa bb**: 1054 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1064 1064 ))) 1065 1065 1066 1066 ((( ... ... @@ -1075,11 +1075,11 @@ 1075 1075 ))) 1076 1076 1077 1077 ((( 1078 -A7 02 aa: 1069 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1079 1079 ))) 1080 1080 1081 1081 ((( 1082 -A7 03 aa: 1073 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1083 1083 ))) 1084 1084 1085 1085 ... ... @@ -1133,7 +1133,7 @@ 1133 1133 ))) 1134 1134 1135 1135 ((( 1136 - (% style="color:#037691" %)**1127 +**Downlink Command:** 1137 1137 ))) 1138 1138 1139 1139 ((( ... ... @@ -1235,18 +1235,34 @@ 1235 1235 1236 1236 If device has not joined network yet: 1237 1237 1238 -* **(% style="color:#037691" %)AT+FDR** 1239 -* **(% style="color:#037691" %)AT+NJM=0** 1240 -* **(% style="color:#037691" %)ATZ** 1229 +(% class="box infomessage" %) 1230 +((( 1231 +**AT+FDR** 1232 +))) 1241 1241 1234 +(% class="box infomessage" %) 1235 +((( 1236 +**AT+NJM=0** 1237 +))) 1242 1242 1239 +(% class="box infomessage" %) 1243 1243 ((( 1241 +**ATZ** 1242 +))) 1243 + 1244 + 1245 +((( 1244 1244 If device already joined network: 1247 +))) 1245 1245 1246 -* **(% style="color:#037691" %)AT+NJM=0** 1247 -* **(% style="color:#037691" %)ATZ** 1249 +(% class="box infomessage" %) 1250 +((( 1251 +**AT+NJM=0** 1252 +))) 1248 1248 1249 - 1254 +(% class="box infomessage" %) 1255 +((( 1256 +**ATZ** 1250 1250 ))) 1251 1251 1252 1252 ... ... @@ -1391,10 +1391,6 @@ 1391 1391 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1392 1392 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1393 1393 1394 - 1395 - 1396 - 1397 - 1398 1398 = 9.Packing Info = 1399 1399 1400 1400 ... ... @@ -1411,10 +1411,6 @@ 1411 1411 * Package Size / pcs : 14.5 x 8 x 5 cm 1412 1412 * Weight / pcs : 170g 1413 1413 1414 - 1415 - 1416 - 1417 - 1418 1418 = 10. FCC Caution for RS485LN-US915 = 1419 1419 1420 1420 (((