From version < 61.34 >
edited by Xiaoling
on 2022/06/14 13:34
To version < 61.20 >
edited by Xiaoling
on 2022/06/14 11:52
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -108,8 +108,6 @@
108 108  
109 109  
110 110  
111 -
112 -
113 113  == 1.3 Features ==
114 114  
115 115  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -123,8 +123,6 @@
123 123  
124 124  
125 125  
126 -
127 -
128 128  == 1.4 Applications ==
129 129  
130 130  * Smart Buildings & Home Automation
... ... @@ -136,8 +136,6 @@
136 136  
137 137  
138 138  
139 -
140 -
141 141  == 1.5 Firmware Change log ==
142 142  
143 143  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -340,6 +340,8 @@
340 340  )))
341 341  
342 342  
337 +
338 +
343 343  === 3.3.2 Configure sensors ===
344 344  
345 345  (((
... ... @@ -365,6 +365,8 @@
365 365  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
366 366  
367 367  
364 +
365 +
368 368  === 3.3.3 Configure read commands for each sampling ===
369 369  
370 370  (((
... ... @@ -595,13 +595,13 @@
595 595  * (((
596 596  (% style="color:#037691" %)**AT Command**
597 597  
598 -(((
599 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**  m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
596 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
597 +
598 +
600 600  )))
601 -)))
602 602  
603 603  (((
604 -
602 +m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
605 605  )))
606 606  
607 607  * (((
... ... @@ -642,9 +642,7 @@
642 642  )))
643 643  
644 644  (((
645 -
646 -
647 -**Example 1**  ~-~-> Configure without ask for uplink (YY=0)
643 +**Example 1** ~-~-> Configure without ask for uplink (YY=0)
648 648  )))
649 649  
650 650  (((
... ... @@ -660,8 +660,6 @@
660 660  )))
661 661  
662 662  (((
663 -
664 -
665 665  So if user want to use downlink command to control to RS485 Alarm, he can use:
666 666  )))
667 667  
... ... @@ -682,7 +682,7 @@
682 682  )))
683 683  
684 684  (((
685 -**Example 2**  ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
679 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
686 686  )))
687 687  
688 688  (((
... ... @@ -694,11 +694,11 @@
694 694  )))
695 695  
696 696  (((
697 -(((
698 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
691 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:
699 699  )))
700 700  
701 -
694 +(((
695 + **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
702 702  )))
703 703  
704 704  (((
... ... @@ -717,7 +717,7 @@
717 717  * (((
718 718  (% style="color:#037691" %)**AT Command:**
719 719  
720 -**AT+PAYVER:    **Set PAYVER field = 1
714 +**AT+PAYVER:  **Set PAYVER field = 1
721 721  
722 722  
723 723  )))
... ... @@ -754,9 +754,9 @@
754 754  (% style="color:#037691" %)**AT Command:**
755 755  )))
756 756  
757 -**AT+COMMANDx:    **Configure RS485 read command to sensor.
751 +**AT+COMMANDx:  **Configure RS485 read command to sensor.
758 758  
759 -**AT+DATACUTx:        **Configure how to handle return from RS485 devices.
753 +**AT+DATACUTx:  **Configure how to handle return from RS485 devices.
760 760  
761 761  
762 762  * (((
... ... @@ -796,8 +796,6 @@
796 796  )))
797 797  
798 798  (((
799 -
800 -
801 801  **Example:**
802 802  )))
803 803  
... ... @@ -819,7 +819,7 @@
819 819  ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ====
820 820  
821 821  (((
822 -**AT+MBFUN** is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
814 +AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
823 823  )))
824 824  
825 825  (((
... ... @@ -839,20 +839,18 @@
839 839  )))
840 840  
841 841  * (((
842 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2  are not configure (0,0,0). So RS485-LN.
834 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN.
843 843  )))
844 844  * (((
845 -AT+COMMAND1= 01 03 00 10 00 08,1  ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
837 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
846 846  )))
847 847  * (((
848 -AT+COMMAND2= 01 02 00 40 00 10,1  ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
849 -
850 -
840 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
851 851  )))
852 852  
853 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %)​
843 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
854 854  
855 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %)​
845 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
856 856  
857 857  
858 858  
... ... @@ -869,13 +869,16 @@
869 869  
870 870  * (((
871 871  (% style="color:#037691" %)** AT Command:**
862 +)))
872 872  
864 +(% class="box infomessage" %)
865 +(((
866 +(((
873 873  **AT+CMDDLaa=hex(bb cc)*1000**
874 874  )))
869 +)))
875 875  
876 876  (((
877 -
878 -
879 879  **Example:**
880 880  )))
881 881  
... ... @@ -900,11 +900,11 @@
900 900  )))
901 901  
902 902  (((
903 -**Example:**
896 + **Example:**
904 904  )))
905 905  
906 906  (((
907 -**0xAA 01 00 01**  ~-~-> Same as  **AT+CMDDL1=1000 ms**
900 + 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
908 908  )))
909 909  
910 910  
... ... @@ -918,8 +918,6 @@
918 918  
919 919  (((
920 920  The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
921 -
922 -
923 923  )))
924 924  
925 925  * (((
... ... @@ -979,8 +979,6 @@
979 979  
980 980  (((
981 981  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
982 -
983 -
984 984  )))
985 985  
986 986  * (((
... ... @@ -1032,35 +1032,35 @@
1032 1032  )))
1033 1033  
1034 1034  (((
1035 -
1036 -
1037 -* Set Baud Rate
1024 +Set Baud Rate:
1038 1038  )))
1039 1039  
1027 +
1040 1040  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1041 1041  
1042 1042  
1043 1043  (((
1044 -* Set UART Parity
1032 +Set UART Parity
1045 1045  )))
1046 1046  
1035 +
1047 1047  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1048 1048  
1049 1049  
1050 1050  (((
1051 -* Set STOPBIT
1040 +Set STOPBIT
1052 1052  )))
1053 1053  
1043 +
1054 1054  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1055 1055  
1056 1056  
1057 -
1058 1058  * (((
1059 1059  (% style="color:#037691" %)** Downlink Payload:**
1060 1060  )))
1061 1061  
1062 1062  (((
1063 -**A7 01 aa bb**:  Same  AT+BAUDR=hex(aa bb)*100
1052 +**A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1064 1064  )))
1065 1065  
1066 1066  (((
... ... @@ -1075,11 +1075,11 @@
1075 1075  )))
1076 1076  
1077 1077  (((
1078 -A7 02 aa:  Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1067 +A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1079 1079  )))
1080 1080  
1081 1081  (((
1082 -A7 03 aa:  Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1071 +A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1083 1083  )))
1084 1084  
1085 1085  
... ... @@ -1133,7 +1133,7 @@
1133 1133  )))
1134 1134  
1135 1135  (((
1136 -(% style="color:#037691" %)** Downlink Command:**
1125 +**Downlink Command:**
1137 1137  )))
1138 1138  
1139 1139  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0