Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -107,6 +107,7 @@ 107 107 * Packet engine up to 256 bytes with CRC 108 108 109 109 110 + 110 110 == 1.3 Features == 111 111 112 112 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -119,6 +119,7 @@ 119 119 * Support Interrupt uplink (Since hardware version v1.2) 120 120 121 121 123 + 122 122 == 1.4 Applications == 123 123 124 124 * Smart Buildings & Home Automation ... ... @@ -129,6 +129,7 @@ 129 129 * Smart Factory 130 130 131 131 134 + 132 132 == 1.5 Firmware Change log == 133 133 134 134 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -332,6 +332,7 @@ 332 332 333 333 334 334 338 + 335 335 === 3.3.2 Configure sensors === 336 336 337 337 ((( ... ... @@ -358,6 +358,7 @@ 358 358 359 359 360 360 365 + 361 361 === 3.3.3 Configure read commands for each sampling === 362 362 363 363 ((( ... ... @@ -588,13 +588,13 @@ 588 588 * ((( 589 589 (% style="color:#037691" %)**AT Command** 590 590 591 -((( 592 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 596 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 597 + 598 + 593 593 ))) 594 -))) 595 595 596 596 ((( 597 - 602 +m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 598 598 ))) 599 599 600 600 * ((( ... ... @@ -635,9 +635,7 @@ 635 635 ))) 636 636 637 637 ((( 638 - 639 - 640 -**Example 1** ~-~-> Configure without ask for uplink (YY=0) 643 +**Example 1** ~-~-> Configure without ask for uplink (YY=0) 641 641 ))) 642 642 643 643 ((( ... ... @@ -653,8 +653,6 @@ 653 653 ))) 654 654 655 655 ((( 656 - 657 - 658 658 So if user want to use downlink command to control to RS485 Alarm, he can use: 659 659 ))) 660 660 ... ... @@ -675,7 +675,7 @@ 675 675 ))) 676 676 677 677 ((( 678 -**Example 2** 679 +**Example 2** ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**) 679 679 ))) 680 680 681 681 ((( ... ... @@ -687,11 +687,11 @@ 687 687 ))) 688 688 689 689 ((( 690 -((( 691 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 691 +RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is: 692 692 ))) 693 693 694 - 694 +((( 695 + **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00 **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00** 695 695 ))) 696 696 697 697 ((( ... ... @@ -710,7 +710,7 @@ 710 710 * ((( 711 711 (% style="color:#037691" %)**AT Command:** 712 712 713 -**AT+PAYVER: 714 +**AT+PAYVER: **Set PAYVER field = 1 714 714 715 715 716 716 ))) ... ... @@ -747,9 +747,9 @@ 747 747 (% style="color:#037691" %)**AT Command:** 748 748 ))) 749 749 750 -**AT+COMMANDx: 751 +**AT+COMMANDx: **Configure RS485 read command to sensor. 751 751 752 -**AT+DATACUTx: 753 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 753 753 754 754 755 755 * ((( ... ... @@ -789,8 +789,6 @@ 789 789 ))) 790 790 791 791 ((( 792 - 793 - 794 794 **Example:** 795 795 ))) 796 796 ... ... @@ -812,7 +812,7 @@ 812 812 ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ==== 813 813 814 814 ((( 815 - **AT+MBFUN**is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].814 +AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 816 816 ))) 817 817 818 818 ((( ... ... @@ -832,20 +832,18 @@ 832 832 ))) 833 833 834 834 * ((( 835 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 834 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 836 836 ))) 837 837 * ((( 838 -AT+COMMAND1= 01 03 00 10 00 08,1 837 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 839 839 ))) 840 840 * ((( 841 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 842 - 843 - 840 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 844 844 ))) 845 845 846 -(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% title="Click and drag to resize" %) 843 +(% aria-label="image-20220602165351-6.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-6.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 847 847 848 -(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% title="Click and drag to resize" %) 845 +(% aria-label="image-20220602165351-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20220602165351-7.png||data-widget="image"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 849 849 850 850 851 851 ... ... @@ -862,13 +862,16 @@ 862 862 863 863 * ((( 864 864 (% style="color:#037691" %)** AT Command:** 862 +))) 865 865 864 +(% class="box infomessage" %) 865 +((( 866 +((( 866 866 **AT+CMDDLaa=hex(bb cc)*1000** 867 867 ))) 869 +))) 868 868 869 869 ((( 870 - 871 - 872 872 **Example:** 873 873 ))) 874 874 ... ... @@ -893,11 +893,11 @@ 893 893 ))) 894 894 895 895 ((( 896 -**Example:** 896 + **Example:** 897 897 ))) 898 898 899 899 ((( 900 - **0xAA 01 00 01**900 + 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 901 901 ))) 902 902 903 903 ... ... @@ -911,8 +911,6 @@ 911 911 912 912 ((( 913 913 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 914 - 915 - 916 916 ))) 917 917 918 918 * ((( ... ... @@ -972,8 +972,6 @@ 972 972 973 973 ((( 974 974 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 975 - 976 - 977 977 ))) 978 978 979 979 * ((( ... ... @@ -1025,35 +1025,35 @@ 1025 1025 ))) 1026 1026 1027 1027 ((( 1028 - 1029 - 1030 -* Set Baud Rate 1024 +Set Baud Rate: 1031 1031 ))) 1032 1032 1027 + 1033 1033 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1034 1034 1035 1035 1036 1036 ((( 1037 - *Set UART Parity1032 +Set UART Parity 1038 1038 ))) 1039 1039 1035 + 1040 1040 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1041 1041 1042 1042 1043 1043 ((( 1044 - *Set STOPBIT1040 +Set STOPBIT 1045 1045 ))) 1046 1046 1043 + 1047 1047 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1048 1048 1049 1049 1050 - 1051 1051 * ((( 1052 1052 (% style="color:#037691" %)** Downlink Payload:** 1053 1053 ))) 1054 1054 1055 1055 ((( 1056 -**A7 01 aa bb**: 1052 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1057 1057 ))) 1058 1058 1059 1059 ((( ... ... @@ -1068,11 +1068,11 @@ 1068 1068 ))) 1069 1069 1070 1070 ((( 1071 -A7 02 aa: 1067 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1072 1072 ))) 1073 1073 1074 1074 ((( 1075 -A7 03 aa: 1071 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1076 1076 ))) 1077 1077 1078 1078 ... ... @@ -1126,7 +1126,7 @@ 1126 1126 ))) 1127 1127 1128 1128 ((( 1129 - (% style="color:#037691" %)**1125 +**Downlink Command:** 1130 1130 ))) 1131 1131 1132 1132 (((