<
From version < 61.30 >
edited by Xiaoling
on 2022/06/14 11:58
To version < 61.33 >
edited by Xiaoling
on 2022/06/14 12:00
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -107,7 +107,6 @@
107 107  * Packet engine up to 256 bytes with CRC
108 108  
109 109  
110 -
111 111  == 1.3 Features ==
112 112  
113 113  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -120,7 +120,6 @@
120 120  * Support Interrupt uplink (Since hardware version v1.2)
121 121  
122 122  
123 -
124 124  == 1.4 Applications ==
125 125  
126 126  * Smart Buildings & Home Automation
... ... @@ -131,7 +131,6 @@
131 131  * Smart Factory
132 132  
133 133  
134 -
135 135  == 1.5 Firmware Change log ==
136 136  
137 137  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -335,7 +335,6 @@
335 335  
336 336  
337 337  
338 -
339 339  === 3.3.2 Configure sensors ===
340 340  
341 341  (((
... ... @@ -362,7 +362,6 @@
362 362  
363 363  
364 364  
365 -
366 366  === 3.3.3 Configure read commands for each sampling ===
367 367  
368 368  (((
... ... @@ -715,7 +715,7 @@
715 715  * (((
716 716  (% style="color:#037691" %)**AT Command:**
717 717  
718 -**AT+PAYVER:  **Set PAYVER field = 1
713 +**AT+PAYVER:    **Set PAYVER field = 1
719 719  
720 720  
721 721  )))
... ... @@ -752,9 +752,9 @@
752 752  (% style="color:#037691" %)**AT Command:**
753 753  )))
754 754  
755 -**AT+COMMANDx:  **Configure RS485 read command to sensor.
750 +**AT+COMMANDx:    **Configure RS485 read command to sensor.
756 756  
757 -**AT+DATACUTx:  **Configure how to handle return from RS485 devices.
752 +**AT+DATACUTx:        **Configure how to handle return from RS485 devices.
758 758  
759 759  
760 760  * (((
... ... @@ -1058,7 +1058,7 @@
1058 1058  )))
1059 1059  
1060 1060  (((
1061 -**A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1056 +**A7 01 aa bb**:  Same  AT+BAUDR=hex(aa bb)*100
1062 1062  )))
1063 1063  
1064 1064  (((
... ... @@ -1073,11 +1073,11 @@
1073 1073  )))
1074 1074  
1075 1075  (((
1076 -A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1071 +A7 02 aa:  Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1077 1077  )))
1078 1078  
1079 1079  (((
1080 -A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1075 +A7 03 aa:  Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1081 1081  )))
1082 1082  
1083 1083  
... ... @@ -1131,7 +1131,7 @@
1131 1131  )))
1132 1132  
1133 1133  (((
1134 -**Downlink Command:**
1129 +(% style="color:#037691" %)** Downlink Command:**
1135 1135  )))
1136 1136  
1137 1137  (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0