From version < 61.3 >
edited by Xiaoling
on 2022/06/14 11:27
To version < 58.30 >
edited by Xiaoling
on 2022/06/06 11:42
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -RS485-LN – RS485 to LoRaWAN Converter User Manual
1 +RS485-LN – RS485 to LoRaWAN Converter
Content
... ... @@ -1,8 +1,9 @@
1 1  (% style="text-align:center" %)
2 -[[image:1653266934636-343.png||height="385" width="385"]]
2 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653266934636-343.png?width=385&height=385&rev=1.1||alt="1653266934636-343.png" height="385" width="385"]]
3 3  
4 4  
5 5  
6 +**RS485-LN – RS485 to LoRaWAN Converter User Manual**
6 6  
7 7  
8 8  
... ... @@ -9,7 +9,59 @@
9 9  
10 10  **Table of Contents:**
11 11  
12 -{{toc/}}
13 +* [[1.Introduction>>path:#H1.Introduction]]
14 +** [[1.1 What is RS485-LN RS485 to LoRaWAN Converter>>path:#H1.1A0WhatisRS485-LNRS485toLoRaWANConverter]]
15 +** [[1.2 Specifications>>path:#H1.2A0Specifications]]
16 +** [[1.3 Features>>path:#H1.3Features]]
17 +** [[1.4 Applications>>path:#H1.4A0Applications]]
18 +** [[1.5 Firmware Change log>>path:#H1.5A0FirmwareChangelog]]
19 +** [[1.6 Hardware Change log>>path:#H1.6HardwareChangelog]]
20 +* [[2. Power ON Device>>path:#H2.PowerONDevice]]
21 +* [[3. Operation Mode>>path:#H3.A0OperationMode]]
22 +** [[3.1 How it works?>>path:#H3.1Howitworks3F]]
23 +** [[3.2 Example to join LoRaWAN network>>path:#H3.2ExampletojoinLoRaWANnetwork]]
24 +** [[3.3 Configure Commands to read data>>path:#H3.3ConfigureCommandstoreaddata]]
25 +*** [[3.3.1 onfigure UART settings for RS485 or TTL communication>>path:#H3.3.1onfigureUARTsettingsforRS485orTTLcommunication]]
26 +*** [[3.3.2 Configure sensors>>path:#H3.3.2Configuresensors]]
27 +*** [[3.3.3 Configure read commands for each sampling>>path:#H3.3.3Configurereadcommandsforeachsampling]]
28 +*** [[3.3.4 Compose the uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
29 +*** [[3.3.5 Uplink on demand>>path:#H3.3.5Uplinkondemand]]
30 +*** [[3.3.6 Uplink on Interrupt>>path:#H3.3.6UplinkonInterrupt]]
31 +** [[3.4 Uplink Payload>>path:#H3.4UplinkPayload]]
32 +** [[3.5 Configure RS485-BL via AT or Downlink>>path:#H3.5ConfigureRS485-BLviaATorDownlink]]
33 +*** [[3.5.1 Common Commands>>path:#H3.5.1CommonCommands]]
34 +*** [[3.5.2 Sensor related commands>>path:#H3.5.2Sensorrelatedcommands]]
35 +*** [[3.5.3 Sensor related commands>>path:#H3.5.3A0Sensorrelatedcommands]]
36 +**** [[RS485 Debug Command>>path:#HRS485DebugCommand]]
37 +**** [[Set Payload version>>path:#HSetPayloadversion]]
38 +**** [[Set RS485 Sampling Commands>>path:#HSetRS485SamplingCommands]]
39 +**** [[Fast command to handle MODBUS device>>path:#HFastcommandtohandleMODBUSdevice]]
40 +**** [[RS485 command timeout>>path:#HRS485commandtimeout]]
41 +**** [[Uplink payload mode>>path:#HUplinkpayloadmode]]
42 +**** [[Manually trigger an Uplink>>path:#HManuallytriggeranUplink]]
43 +**** [[Clear RS485 Command>>path:#HClearRS485Command]]
44 +**** [[Set Serial Communication Parameters>>path:#HSetSerialCommunicationParameters]]
45 +** [[3.6 Listening mode for RS485 network>>path:#H3.6A0ListeningmodeforRS485network]]
46 +** [[3.7 Buttons>>path:#H3.7Buttons]]
47 +** [[3.8 LEDs>>path:#H3.8LEDs]]
48 +* [[4. Case Study>>path:#H4.CaseStudy]]
49 +* [[5. Use AT Command>>path:#H5.UseATCommand]]
50 +** [[5.1 Access AT Command>>path:#H5.1AccessATCommand]]
51 +** [[5.2 Common AT Command Sequence>>path:#H5.2CommonATCommandSequence]]
52 +*** [[5.2.1 Multi-channel ABP mode (Use with SX1301/LG308)>>path:#H5.2.1Multi-channelABPmode28UsewithSX13012FLG30829]]
53 +*** [[5.5.2 Single-channel ABP mode (Use with LG01/LG02)>>path:#H5.5.2Single-channelABPmode28UsewithLG012FLG0229]]
54 +* [[6. FAQ>>path:#H6.FAQ]]
55 +** [[6.1 How to upgrade the image?>>path:#H6.1Howtoupgradetheimage3F]]
56 +** [[6.2 How to change the LoRa Frequency Bands/Region?>>path:#H6.2HowtochangetheLoRaFrequencyBands2FRegion3F]]
57 +** [[6.3 How many RS485-Slave can RS485-BL connects?>>path:#H6.3HowmanyRS485-SlavecanRS485-BLconnects3F]]
58 +** [[6.4 Compatible question to ChirpStack and TTI LoRaWAN server ?>>path:#H6.4CompatiblequestiontoChirpStackandTTILoRaWANserver3F]]
59 +* [[7. Trouble Shooting>>path:#H7.TroubleShooting]]
60 +** [[7.1 Downlink doesn’t work, how to solve it?>>path:#H7.1Downlinkdoesn2019twork2Chowtosolveit3F]]
61 +** [[7.2 Why I can’t join TTN V3 in US915 /AU915 bands?>>path:#H7.2WhyIcan2019tjoinTTNV3inUS9152FAU915bands3F]]
62 +* [[8. Order Info>>path:#H8.OrderInfo]]
63 +* [[9.Packing Info>>path:#H9.PackingInfo]]
64 +* [[10. FCC Caution for RS485LN-US915>>path:#H10.FCCCautionforRS485LN-US915]]
65 +* [[11. Support>>path:#H11.Support]]
13 13  
14 14  
15 15  
... ... @@ -24,8 +24,6 @@
24 24  (((
25 25  (((
26 26  (((
27 -
28 -
29 29  The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
30 30  )))
31 31  )))
... ... @@ -49,13 +49,11 @@
49 49  
50 50  (((
51 51  (% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]]
52 -
53 -
54 54  )))
55 55  )))
56 56  )))
57 57  
58 -[[image:1653267211009-519.png||height="419" width="724"]]
107 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653267211009-519.png?width=724&height=419&rev=1.1||alt="1653267211009-519.png" height="419" width="724"]]
59 59  
60 60  
61 61  == 1.2 Specifications ==
... ... @@ -95,8 +95,6 @@
95 95  * Automatic RF Sense and CAD with ultra-fast AFC.
96 96  * Packet engine up to 256 bytes with CRC
97 97  
98 -
99 -
100 100  == 1.3 Features ==
101 101  
102 102  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -108,8 +108,6 @@
108 108  * Support Modbus protocol
109 109  * Support Interrupt uplink (Since hardware version v1.2)
110 110  
111 -
112 -
113 113  == 1.4 Applications ==
114 114  
115 115  * Smart Buildings & Home Automation
... ... @@ -119,8 +119,6 @@
119 119  * Smart Cities
120 120  * Smart Factory
121 121  
122 -
123 -
124 124  == 1.5 Firmware Change log ==
125 125  
126 126  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -154,7 +154,7 @@
154 154  Once there is power, the RS485-LN will be on.
155 155  )))
156 156  
157 -[[image:1653268091319-405.png]]
200 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268091319-405.png?rev=1.1||alt="1653268091319-405.png"]]
158 158  
159 159  
160 160  )))
... ... @@ -175,7 +175,7 @@
175 175  
176 176  Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
177 177  
178 -[[image:1653268155545-638.png||height="334" width="724"]]
221 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268155545-638.png?width=724&height=334&rev=1.1||alt="1653268155545-638.png" height="334" width="724"]]
179 179  
180 180  
181 181  (((
... ... @@ -187,15 +187,14 @@
187 187  485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
188 188  )))
189 189  
190 -[[image:1653268227651-549.png||height="592" width="720"]]
233 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653268227651-549.png?width=720&height=592&rev=1.1||alt="1653268227651-549.png" height="592" width="720"]]
191 191  
192 -
193 193  (((
194 -The LG308 is already set to connect to [[TTN V3 network >>path:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:
236 +The LG308 is already set to connect to (% class="wikiinternallink" %)[[TTN V3 network >>url:https://www.thethingsnetwork.org/]](%%). So what we need to now is only configure the TTN V3:
195 195  )))
196 196  
197 197  (((
198 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-LN.
240 +**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN.
199 199  )))
200 200  
201 201  (((
... ... @@ -203,9 +203,8 @@
203 203  )))
204 204  )))
205 205  
206 -[[image:1652953462722-299.png]]
248 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953462722-299.png?rev=1.1||alt="1652953462722-299.png"]]
207 207  
208 -
209 209  (((
210 210  (((
211 211  User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
... ... @@ -212,34 +212,32 @@
212 212  )))
213 213  
214 214  (((
215 -**Add APP EUI in the application.**
256 +Add APP EUI in the application.
216 216  )))
217 217  )))
218 218  
219 -[[image:image-20220519174512-1.png]]
260 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-1.png?rev=1.1||alt="image-20220519174512-1.png"]]
220 220  
221 -[[image:image-20220519174512-2.png||height="323" width="720"]]
262 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-2.png?width=720&height=323&rev=1.1||alt="image-20220519174512-2.png" height="323" width="720"]]
222 222  
223 -[[image:image-20220519174512-3.png||height="556" width="724"]]
264 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-3.png?width=724&height=556&rev=1.1||alt="image-20220519174512-3.png" height="556" width="724"]]
224 224  
225 -[[image:image-20220519174512-4.png]]
266 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220519174512-4.png?rev=1.1||alt="image-20220519174512-4.png"]]
226 226  
227 227  You can also choose to create the device manually.
228 228  
229 -[[image:1652953542269-423.png||height="710" width="723"]]
270 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953542269-423.png?width=723&height=710&rev=1.1||alt="1652953542269-423.png" height="710" width="723"]]
230 230  
272 +Add APP KEY and DEV EUI
231 231  
274 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953553383-907.png?width=724&height=514&rev=1.1||alt="1652953553383-907.png" height="514" width="724"]]
232 232  
233 -**Add APP KEY and DEV EUI**
234 234  
235 -[[image:1652953553383-907.png||height="514" width="724"]]
236 -
237 -
238 238  (((
239 -(% style="color:blue" %)**Step 2**(%%): Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
278 +**Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
240 240  )))
241 241  
242 -[[image:1652953568895-172.png||height="232" width="724"]]
281 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1652953568895-172.png?width=724&height=232&rev=1.1||alt="1652953568895-172.png" height="232" width="724"]]
243 243  
244 244  
245 245  == 3.3 Configure Commands to read data ==
... ... @@ -246,15 +246,11 @@
246 246  
247 247  (((
248 248  (((
249 -(((
250 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>||anchor="H3.5ConfigureRS485-LNviaATorDownlink"]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
288 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#H3.5ConfigureRS485-BLviaATorDownlink]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
251 251  )))
252 -)))
253 253  
254 254  (((
255 -(((
256 256  (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
257 -)))
258 258  
259 259  
260 260  )))
... ... @@ -322,9 +322,6 @@
322 322  )))
323 323  )))
324 324  
325 -
326 -
327 -
328 328  === 3.3.2 Configure sensors ===
329 329  
330 330  (((
... ... @@ -336,22 +336,13 @@
336 336  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
337 337  |=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
338 338  |AT+CFGDEV|(% style="width:110px" %)(((
339 -(((
340 340  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
341 -)))
342 342  
343 -(((
344 344  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
345 -)))
346 346  
347 -(((
348 348  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
349 -)))
350 350  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
351 351  
352 -
353 -
354 -
355 355  === 3.3.3 Configure read commands for each sampling ===
356 356  
357 357  (((
... ... @@ -364,7 +364,7 @@
364 364  During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
365 365  
366 366  
367 -(% style="color:#037691" %)**Each RS485 commands include two parts:**
390 +**Each RS485 commands include two parts:**
368 368  
369 369  ~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar.
370 370  
... ... @@ -379,11 +379,11 @@
379 379  Below are examples for the how above AT Commands works.
380 380  
381 381  
382 -(% style="color:#037691" %)**AT+COMMANDx **(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
405 +**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
383 383  
384 384  (% border="1" style="background-color:#4bacc6; color:white; width:499px" %)
385 385  |(% style="width:496px" %)(((
386 -(% style="color:#037691" %)**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
409 +**AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
387 387  
388 388  **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
389 389  
... ... @@ -395,7 +395,7 @@
395 395  In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
396 396  
397 397  
398 -(% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
421 +**AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
399 399  
400 400  (% border="1" style="background-color:#4bacc6; color:white; width:510px" %)
401 401  |(% style="width:510px" %)(((
... ... @@ -408,21 +408,20 @@
408 408  
409 409  **Examples:**
410 410  
411 -* (% style="color:#037691" %)**Grab bytes**
434 +* Grab bytes:
412 412  
413 -[[image:image-20220602153621-1.png]]
436 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-1.png?rev=1.1||alt="image-20220602153621-1.png"]]
414 414  
415 415  
416 -* (% style="color:#037691" %)**Grab a section**
439 +* Grab a section.
417 417  
418 -[[image:image-20220602153621-2.png]]
441 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-2.png?rev=1.1||alt="image-20220602153621-2.png"]]
419 419  
420 420  
421 -* (% style="color:#037691" %)**Grab different sections**
444 +* Grab different sections.
422 422  
423 -[[image:image-20220602153621-3.png]]
446 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602153621-3.png?rev=1.1||alt="image-20220602153621-3.png"]]
424 424  
425 -
426 426  
427 427  )))
428 428  
... ... @@ -456,7 +456,7 @@
456 456  Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
457 457  )))
458 458  
459 -[[image:1653269759169-150.png||height="513" width="716"]]
481 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1653269759169-150.png?width=716&height=513&rev=1.1||alt="1653269759169-150.png" height="513" width="716"]]
460 460  
461 461  
462 462  (% style="color:#037691" %)**Examples: AT+DATAUP=1**
... ... @@ -474,7 +474,7 @@
474 474  1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
475 475  1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
476 476  
477 -[[image:image-20220602155039-4.png]]
499 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602155039-4.png?rev=1.1||alt="image-20220602155039-4.png"]]
478 478  
479 479  
480 480  So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
... ... @@ -499,7 +499,7 @@
499 499  
500 500  Below are the uplink payloads:
501 501  
502 -[[image:1654157178836-407.png]]
524 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157178836-407.png?rev=1.1||alt="1654157178836-407.png"]]
503 503  
504 504  
505 505  === 3.3.5 Uplink on demand ===
... ... @@ -518,7 +518,7 @@
518 518  
519 519  RS485-LN support external Interrupt uplink since hardware v1.2 release.
520 520  
521 -[[image:1654157342174-798.png]]
543 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654157342174-798.png?rev=1.1||alt="1654157342174-798.png"]]
522 522  
523 523  Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
524 524  
... ... @@ -526,12 +526,12 @@
526 526  == 3.4 Uplink Payload ==
527 527  
528 528  
529 -[[image:image-20220606110929-1.png]]
551 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220606110929-1.png?rev=1.1||alt="image-20220606110929-1.png"]]
530 530  
531 531  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
532 532  
533 533  
534 -== 3.5 Configure RS485-LN via AT or Downlink ==
556 +== 3.5 Configure RS485-BL via AT or Downlink ==
535 535  
536 536  (((
537 537  User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
... ... @@ -542,7 +542,7 @@
542 542  )))
543 543  
544 544  * (((
545 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
567 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
546 546  )))
547 547  
548 548  * (((
... ... @@ -556,7 +556,7 @@
556 556  
557 557  === 3.5.1 Common Commands ===
558 558  
559 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
581 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
560 560  
561 561  
562 562  === 3.5.2 Sensor related commands ===
... ... @@ -563,7 +563,7 @@
563 563  
564 564  Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
565 565  
566 -[[image:image-20220602163333-5.png||height="263" width="1160"]]
588 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602163333-5.png?width=1160&height=263&rev=1.1||alt="image-20220602163333-5.png" height="263" width="1160"]]
567 567  
568 568  The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
569 569  
... ... @@ -688,7 +688,7 @@
688 688  )))
689 689  
690 690  (((
691 - [[image:1654159460680-153.png]]
713 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654159460680-153.png?rev=1.1||alt="1654159460680-153.png"]]
692 692  )))
693 693  
694 694  
... ... @@ -697,7 +697,7 @@
697 697  ==== **Set Payload version** ====
698 698  
699 699  (((
700 -This is the first byte of the uplink payload. RS485-LN can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
722 +This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
701 701  )))
702 702  
703 703  * (((
... ... @@ -733,7 +733,7 @@
733 733  )))
734 734  
735 735  (((
736 -These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
758 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#H3.3.3Configurereadcommandsforeachsampling]].
737 737  )))
738 738  
739 739  (((
... ... @@ -795,7 +795,7 @@
795 795  XX XX XX XX: AT+COMMAND or AT+DATACUT command
796 796  )))
797 797  * (((
798 -YY:  If YY=0, RS485-LN will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
820 +YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command.
799 799  )))
800 800  
801 801  (((
... ... @@ -849,9 +849,9 @@
849 849  AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
850 850  )))
851 851  
852 -[[image:image-20220602165351-6.png]]
874 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-6.png?rev=1.1||alt="image-20220602165351-6.png"]]
853 853  
854 -[[image:image-20220602165351-7.png]]
876 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602165351-7.png?rev=1.1||alt="image-20220602165351-7.png"]]
855 855  
856 856  
857 857  
... ... @@ -919,7 +919,7 @@
919 919  )))
920 920  
921 921  (((
922 -The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]]
944 +The use of this command please see: [[Compose Uplink payload>>path:#H3.3.4Composetheuplinkpayload]]
923 923  )))
924 924  
925 925  * (((
... ... @@ -970,7 +970,7 @@
970 970  )))
971 971  
972 972  (((
973 -No AT Command for this, user can press the [[ACT button>>||anchor="H3.7Buttons"]] for 1 second for the same.
995 +No AT Command for this, user can press the [[ACT button>>path:#H3.7Buttons]] for 1 second for the same.
974 974  )))
975 975  
976 976  (((
... ... @@ -1018,7 +1018,7 @@
1018 1018  The uplink screen shot is:
1019 1019  )))
1020 1020  
1021 -[[image:1654160691922-496.png]]
1043 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654160691922-496.png?rev=1.1||alt="1654160691922-496.png"]]
1022 1022  
1023 1023  
1024 1024  * (((
... ... @@ -1119,7 +1119,7 @@
1119 1119  RS485-LN supports listening mode, it can listen the RS485 network packets and send them via LoRaWAN uplink. Below is the structure. The blue arrow shows the RS485 network packets to RS485-LN.
1120 1120  )))
1121 1121  
1122 -[[image:image-20220602171200-8.png||height="567" width="1007"]]
1144 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-8.png?width=1007&height=567&rev=1.1||alt="image-20220602171200-8.png" height="567" width="1007"]]
1123 1123  
1124 1124  (((
1125 1125  To enable the listening mode, use can run the command AT+RXMODE.
... ... @@ -1130,29 +1130,29 @@
1130 1130  )))
1131 1131  
1132 1132  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
1133 -|=(% style="width: 100px;" %)(((
1134 -**Command example**
1135 -)))|=(% style="width: 400px;" %)(((
1155 +|=(% style="width: 161px;" %)(((
1156 +**Command example:**
1157 +)))|=(% style="width: 337px;" %)(((
1136 1136  **Function**
1137 1137  )))
1138 -|(% style="width:100px" %)(((
1160 +|(% style="width:161px" %)(((
1139 1139  AT+RXMODE=1,10
1140 -)))|(% style="width:400px" %)(((
1162 +)))|(% style="width:337px" %)(((
1141 1141  Enable listening mode 1, if RS485-LN has received more than 10 RS485 commands from the network. RS485-LN will send these commands via LoRaWAN uplinks.
1142 1142  )))
1143 -|(% style="width:100px" %)(((
1165 +|(% style="width:161px" %)(((
1144 1144  AT+RXMODE=2,500
1145 -)))|(% style="width:400px" %)(((
1167 +)))|(% style="width:337px" %)(((
1146 1146  Enable listening mode 2, RS485-LN will capture and send a 500ms content once from the first detect of character. Max value is 65535 ms
1147 1147  )))
1148 -|(% style="width:100px" %)(((
1170 +|(% style="width:161px" %)(((
1149 1149  AT+RXMODE=0,0
1150 -)))|(% style="width:400px" %)(((
1172 +)))|(% style="width:337px" %)(((
1151 1151  Disable listening mode. This is the default settings.
1152 1152  )))
1153 -|(% style="width:100px" %)(((
1175 +|(% style="width:161px" %)(((
1154 1154  
1155 -)))|(% style="width:400px" %)(((
1177 +)))|(% style="width:337px" %)(((
1156 1156  A6 aa bb cc  same as AT+RXMODE=aa,(bb<<8 | cc)
1157 1157  )))
1158 1158  
... ... @@ -1193,7 +1193,7 @@
1193 1193  )))
1194 1194  
1195 1195  (((
1196 -[[image:image-20220602171200-9.png]]
1218 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602171200-9.png?rev=1.1||alt="image-20220602171200-9.png"]]
1197 1197  )))
1198 1198  
1199 1199  (((
... ... @@ -1201,10 +1201,8 @@
1201 1201  )))
1202 1202  
1203 1203  (((
1204 -(((
1205 1205  (% style="color:red" %)Notice: Listening mode can work with the default polling mode of RS485-LN. When RS485-LN is in to send the RS485 commands (from AT+COMMANDx), the listening mode will be interrupt for a while.
1206 1206  )))
1207 -)))
1208 1208  
1209 1209  
1210 1210  == 3.7 Buttons ==
... ... @@ -1211,22 +1211,23 @@
1211 1211  
1212 1212  
1213 1213  (% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1214 -|=(% style="width: 50px;" %)**Button**|=(% style="width: 361px;" %)**Feature**
1215 -|(% style="width:50px" %)**ACT**|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1216 -|(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1217 -|(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1234 +|=(% style="width: 30px;" %)**Button**|=(% style="width: 355px;" %)**Feature**
1235 +|=(% style="width: 30px;" %)**ACT**|(% style="width:355px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1236 +|=(% style="width: 30px;" %)**RST**|(% style="width:355px" %)Reboot RS485
1237 +|=(% style="width: 30px;" %)**PRO**|(% style="width:355px" %)Use for upload image, see [[How to Update Image>>path:#H6.1Howtoupgradetheimage3F]]
1218 1218  
1239 +
1219 1219  == 3.8 LEDs ==
1220 1220  
1242 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:500px" %)
1243 +|=(% style="width: 30px;" %)**LEDs**|=(% style="width: 400px;" %)**Feature**
1244 +|(% style="width:30px" %)**PWR**|=(% style="width: 400px;" %)Always on if there is power
1245 +|(% style="width:30px" %)**SYS**|=(% style="width: 400px;" %)After device is powered on, the SYS will (% style="color:green" %)fast blink in GREEN (%%)for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)on GREEN for 5 seconds(%%). SYS will (% style="color:green" %)blink Blue(%%) on every upload and (% style="color:green" %)blink Green(%%) once receive a downlink message.
1221 1221  
1222 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:430px" %)
1223 -|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1224 -|**PWR**|Always on if there is power
1225 -|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1226 1226  
1227 1227  = 4. Case Study =
1228 1228  
1229 -User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]]
1250 +User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>path:/xwiki/bin/view/Main/Application%20Note%20%3A%20Communicate%20with%20Different%20Sensors%20-----%20RS485-LN%20%20RS485-BL/]]
1230 1230  
1231 1231  
1232 1232  = 5. Use AT Command =
... ... @@ -1234,21 +1234,21 @@
1234 1234  == 5.1 Access AT Command ==
1235 1235  
1236 1236  (((
1237 -RS485-LN supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-LN to use AT command, as below.
1258 +RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1238 1238  )))
1239 1239  
1240 -[[image:1654162355560-817.png]]
1261 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162355560-817.png?rev=1.1||alt="1654162355560-817.png"]]
1241 1241  
1242 1242  
1243 1243  (((
1244 -In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-LN. The default password is 123456. Below is the output for reference:
1265 +In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1245 1245  )))
1246 1246  
1247 -[[image:1654162368066-342.png]]
1268 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162368066-342.png?rev=1.1||alt="1654162368066-342.png"]]
1248 1248  
1249 1249  
1250 1250  (((
1251 -More detail AT Command manual can be found at [[AT Command Manual>>https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1272 +More detail AT Command manual can be found at [[AT Command Manual>>url:https://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1252 1252  )))
1253 1253  
1254 1254  
... ... @@ -1275,9 +1275,7 @@
1275 1275  )))
1276 1276  
1277 1277  
1278 -(((
1279 1279  If device already joined network:
1280 -)))
1281 1281  
1282 1282  (% class="box infomessage" %)
1283 1283  (((
... ... @@ -1316,14 +1316,12 @@
1316 1316  
1317 1317  (% style="color:red" %)**Note:**
1318 1318  
1319 -(((
1320 1320  (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server.
1321 1321  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1322 1322  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1323 1323  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1324 -)))
1325 1325  
1326 -[[image:1654162478620-421.png]]
1343 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162478620-421.png?rev=1.1||alt="1654162478620-421.png"]]
1327 1327  
1328 1328  
1329 1329  = 6. FAQ =
... ... @@ -1330,69 +1330,49 @@
1330 1330  
1331 1331  == 6.1 How to upgrade the image? ==
1332 1332  
1333 -(((
1334 1334  The RS485-LN LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-LN to:
1335 -)))
1336 1336  
1337 -* (((
1338 -Support new features
1339 -)))
1340 -* (((
1341 -For bug fix
1342 -)))
1343 -* (((
1344 -Change LoRaWAN bands.
1345 -)))
1352 +* Support new features
1353 +* For bug fix
1354 +* Change LoRaWAN bands.
1346 1346  
1347 -(((
1348 1348  Below shows the hardware connection for how to upload an image to RS485-LN:
1349 -)))
1350 1350  
1351 -[[image:1654162535040-878.png]]
1358 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/1654162535040-878.png?rev=1.1||alt="1654162535040-878.png"]]
1352 1352  
1353 -(((
1354 1354  **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1355 -)))
1356 1356  
1357 -(((
1358 1358  **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1359 -)))
1360 1360  
1361 -(((
1362 1362  **Step3: **Open flashloader; choose the correct COM port to update.
1363 -)))
1364 1364  
1365 1365  (((
1366 -(((
1367 -(((
1368 1368  (% style="color:blue" %) Hold down the PRO button and then momentarily press the RST reset button and the SYS led will change from OFF to ON, While SYS LED is RED ON, it means the RS485-LN is ready to be program.
1369 1369  )))
1370 -)))
1371 -)))
1372 1372  
1373 1373  
1374 -[[image:image-20220602175818-12.png]]
1371 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175818-12.png?rev=1.1||alt="image-20220602175818-12.png"]]
1375 1375  
1376 1376  
1377 -[[image:image-20220602175848-13.png]]
1374 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175848-13.png?rev=1.1||alt="image-20220602175848-13.png"]]
1378 1378  
1379 1379  
1380 -[[image:image-20220602175912-14.png]]
1377 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175912-14.png?rev=1.1||alt="image-20220602175912-14.png"]]
1381 1381  
1382 1382  
1383 1383  **Notice**: In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1384 1384  
1385 -[[image:image-20220602175638-10.png]]
1382 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/RS485-LN%20%E2%80%93%20RS485%20to%20LoRaWAN%20Converter/WebHome/image-20220602175638-10.png?rev=1.1||alt="image-20220602175638-10.png"]]
1386 1386  
1387 1387  
1388 1388  == 6.2 How to change the LoRa Frequency Bands/Region? ==
1389 1389  
1390 -User can follow the introduction for [[how to upgrade image>>||anchor="H6.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download.
1387 +User can follow the introduction for [[how to upgrade image>>path:#H6.1Howtoupgradetheimage3F]]. When download the images, choose the required image file for download.
1391 1391  
1392 1392  
1393 -== 6.3 How many RS485-Slave can RS485-LN connects? ==
1390 +== 6.3 How many RS485-Slave can RS485-BL connects? ==
1394 1394  
1395 -The RS485-LN can support max 32 RS485 devices. Each uplink command of RS485-LN can support max 16 different RS485 command. So RS485-LN can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1392 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#H3.3.3Configurereadcommandsforeachsampling]].
1396 1396  
1397 1397  
1398 1398  == 6.4 Compatible question to ChirpStack and TTI LoRaWAN server ? ==
... ... @@ -1399,7 +1399,7 @@
1399 1399  
1400 1400  When user need to use with ChirpStack or TTI. Please set AT+RPL=4.
1401 1401  
1402 -Detail info check this link: [[Set Packet Receiving Response Level>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.23SetPacketReceivingResponseLevel"]]
1399 +Detail info check this link: [[Set Packet Receiving Response Level>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.23SetPacketReceivingResponseLevel]]
1403 1403  
1404 1404  
1405 1405  = 7. Trouble Shooting =
... ... @@ -1406,12 +1406,12 @@
1406 1406  
1407 1407  == 7.1 Downlink doesn’t work, how to solve it? ==
1408 1408  
1409 -Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1406 +Please see this link for debug: [[LoRaWAN Communication Debug>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/]]
1410 1410  
1411 1411  
1412 1412  == 7.2 Why I can’t join TTN V3 in US915 /AU915 bands? ==
1413 1413  
1414 -It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1411 +It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>path:/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]]
1415 1415  
1416 1416  
1417 1417  = 8. Order Info =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0