Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,6 +12,11 @@ 12 12 13 13 14 14 15 + 16 + 17 + 18 + 19 + 15 15 **Table of Contents:** 16 16 17 17 {{toc/}} ... ... @@ -107,7 +107,6 @@ 107 107 * Packet engine up to 256 bytes with CRC 108 108 109 109 110 - 111 111 == 1.3 Features == 112 112 113 113 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -120,7 +120,6 @@ 120 120 * Support Interrupt uplink (Since hardware version v1.2) 121 121 122 122 123 - 124 124 == 1.4 Applications == 125 125 126 126 * Smart Buildings & Home Automation ... ... @@ -131,7 +131,6 @@ 131 131 * Smart Factory 132 132 133 133 134 - 135 135 == 1.5 Firmware Change log == 136 136 137 137 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -333,9 +333,6 @@ 333 333 ))) 334 334 ))) 335 335 336 - 337 - 338 - 339 339 === 3.3.2 Configure sensors === 340 340 341 341 ((( ... ... @@ -360,9 +360,6 @@ 360 360 ))) 361 361 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 362 362 363 - 364 - 365 - 366 366 === 3.3.3 Configure read commands for each sampling === 367 367 368 368 ((( ... ... @@ -715,7 +715,7 @@ 715 715 * ((( 716 716 (% style="color:#037691" %)**AT Command:** 717 717 718 -**AT+PAYVER: 714 +**AT+PAYVER: **Set PAYVER field = 1 719 719 720 720 721 721 ))) ... ... @@ -752,9 +752,9 @@ 752 752 (% style="color:#037691" %)**AT Command:** 753 753 ))) 754 754 755 -**AT+COMMANDx: 751 +**AT+COMMANDx: **Configure RS485 read command to sensor. 756 756 757 -**AT+DATACUTx: 753 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 758 758 759 759 760 760 * ((( ... ... @@ -916,6 +916,8 @@ 916 916 917 917 ((( 918 918 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 915 + 916 + 919 919 ))) 920 920 921 921 * ((( ... ... @@ -975,6 +975,8 @@ 975 975 976 976 ((( 977 977 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 976 + 977 + 978 978 ))) 979 979 980 980 * ((( ... ... @@ -1026,35 +1026,35 @@ 1026 1026 ))) 1027 1027 1028 1028 ((( 1029 -Set Baud Rate: 1029 + 1030 + 1031 +* Set Baud Rate 1030 1030 ))) 1031 1031 1032 - 1033 1033 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1034 1034 1035 1035 1036 1036 ((( 1037 -Set UART Parity 1038 +* Set UART Parity 1038 1038 ))) 1039 1039 1040 - 1041 1041 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1042 1042 1043 1043 1044 1044 ((( 1045 -Set STOPBIT 1045 +* Set STOPBIT 1046 1046 ))) 1047 1047 1048 - 1049 1049 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1050 1050 1051 1051 1051 + 1052 1052 * ((( 1053 1053 (% style="color:#037691" %)** Downlink Payload:** 1054 1054 ))) 1055 1055 1056 1056 ((( 1057 -**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1057 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1058 1058 ))) 1059 1059 1060 1060 ((( ... ... @@ -1069,11 +1069,11 @@ 1069 1069 ))) 1070 1070 1071 1071 ((( 1072 -A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1072 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1073 1073 ))) 1074 1074 1075 1075 ((( 1076 -A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1076 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1077 1077 ))) 1078 1078 1079 1079 ... ... @@ -1127,7 +1127,7 @@ 1127 1127 ))) 1128 1128 1129 1129 ((( 1130 -**Downlink Command:** 1130 +(% style="color:#037691" %)** Downlink Command:** 1131 1131 ))) 1132 1132 1133 1133 ((( ... ... @@ -1186,6 +1186,7 @@ 1186 1186 |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1187 1187 |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1188 1188 1189 + 1189 1189 == 3.8 LEDs == 1190 1190 1191 1191 ... ... @@ -1194,6 +1194,7 @@ 1194 1194 |**PWR**|Always on if there is power 1195 1195 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1196 1196 1198 + 1197 1197 = 4. Case Study = 1198 1198 1199 1199 User can check this URL for some case studies: [[APP RS485 COMMUNICATE WITH SENSORS>>doc:Main.Application Note \: Communicate with Different Sensors ----- RS485-LN RS485-BL.WebHome]] ... ... @@ -1225,38 +1225,24 @@ 1225 1225 1226 1226 == 5.2 Common AT Command Sequence == 1227 1227 1230 + 1228 1228 === 5.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1229 1229 1230 1230 If device has not joined network yet: 1231 1231 1232 -(% class="box infomessage" %) 1233 -((( 1234 -**AT+FDR** 1235 -))) 1235 +* (% style="color:#037691" %)**AT+FDR** 1236 +* (% style="color:#037691" %)**AT+NJM=0** 1237 +* (% style="color:#037691" %)**ATZ** 1236 1236 1237 -(% class="box infomessage" %) 1238 1238 ((( 1239 -**AT+NJM=0** 1240 -))) 1240 + 1241 1241 1242 -(% class="box infomessage" %) 1243 -((( 1244 -**ATZ** 1245 -))) 1246 - 1247 - 1248 -((( 1249 1249 If device already joined network: 1250 -))) 1251 1251 1252 -(% class="box infomessage" %) 1253 -((( 1254 -**AT+NJM=0** 1255 -))) 1244 +* (% style="color:#037691" %)**AT+NJM=0** 1245 +* (% style="color:#037691" %)**ATZ** 1256 1256 1257 -(% class="box infomessage" %) 1258 -((( 1259 -**ATZ** 1247 + 1260 1260 ))) 1261 1261 1262 1262 ... ... @@ -1263,25 +1263,25 @@ 1263 1263 === 5.5.2 Single-channel ABP mode (Use with LG01/LG02) === 1264 1264 1265 1265 1266 -(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1254 +(% style="background-color:#dcdcdc" %)**AT+FDR** (%%) Reset Parameters to Factory Default, Keys Reserve 1267 1267 1268 -(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%)Set to ABP mode 1256 +(% style="background-color:#dcdcdc" %)**AT+NJM=0 **(%%) Set to ABP mode 1269 1269 1270 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%)Set the Adaptive Data Rate Off 1258 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) Set the Adaptive Data Rate Off 1271 1271 1272 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%)Set Data Rate 1260 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) Set Data Rate 1273 1273 1274 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1262 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000** (%%) Set transmit interval to 60 seconds 1275 1275 1276 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1264 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) Set transmit frequency to 868.4Mhz 1277 1277 1278 -(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1266 +(% style="background-color:#dcdcdc" %)**AT+RX2FQ=868400000** (%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1279 1279 1280 -(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1268 +(% style="background-color:#dcdcdc" %)**AT+RX2DR=5** (%%) Set RX2DR to match the downlink DR from server. see below 1281 1281 1282 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1270 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26** (%%) 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1283 1283 1284 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1272 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) Reset MCU 1285 1285 1286 1286 1287 1287 (% style="color:red" %)**Note:** ... ... @@ -1401,6 +1401,7 @@ 1401 1401 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1402 1402 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1403 1403 1392 + 1404 1404 = 9.Packing Info = 1405 1405 1406 1406 ... ... @@ -1417,6 +1417,7 @@ 1417 1417 * Package Size / pcs : 14.5 x 8 x 5 cm 1418 1418 * Weight / pcs : 170g 1419 1419 1409 + 1420 1420 = 10. FCC Caution for RS485LN-US915 = 1421 1421 1422 1422 (((