Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -108,6 +108,8 @@ 108 108 109 109 110 110 111 + 112 + 111 111 == 1.3 Features == 112 112 113 113 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -121,6 +121,8 @@ 121 121 122 122 123 123 126 + 127 + 124 124 == 1.4 Applications == 125 125 126 126 * Smart Buildings & Home Automation ... ... @@ -132,6 +132,8 @@ 132 132 133 133 134 134 139 + 140 + 135 135 == 1.5 Firmware Change log == 136 136 137 137 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -334,8 +334,6 @@ 334 334 ))) 335 335 336 336 337 - 338 - 339 339 === 3.3.2 Configure sensors === 340 340 341 341 ((( ... ... @@ -361,8 +361,6 @@ 361 361 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 362 362 363 363 364 - 365 - 366 366 === 3.3.3 Configure read commands for each sampling === 367 367 368 368 ((( ... ... @@ -715,7 +715,7 @@ 715 715 * ((( 716 716 (% style="color:#037691" %)**AT Command:** 717 717 718 -**AT+PAYVER: 720 +**AT+PAYVER: **Set PAYVER field = 1 719 719 720 720 721 721 ))) ... ... @@ -752,9 +752,9 @@ 752 752 (% style="color:#037691" %)**AT Command:** 753 753 ))) 754 754 755 -**AT+COMMANDx: 757 +**AT+COMMANDx: **Configure RS485 read command to sensor. 756 756 757 -**AT+DATACUTx: 759 +**AT+DATACUTx: **Configure how to handle return from RS485 devices. 758 758 759 759 760 760 * ((( ... ... @@ -898,11 +898,11 @@ 898 898 ))) 899 899 900 900 ((( 901 - 903 +**Example:** 902 902 ))) 903 903 904 904 ((( 905 - 907 +**0xAA 01 00 01** ~-~-> Same as **AT+CMDDL1=1000 ms** 906 906 ))) 907 907 908 908 ... ... @@ -916,6 +916,8 @@ 916 916 917 917 ((( 918 918 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 921 + 922 + 919 919 ))) 920 920 921 921 * ((( ... ... @@ -975,6 +975,8 @@ 975 975 976 976 ((( 977 977 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 982 + 983 + 978 978 ))) 979 979 980 980 * ((( ... ... @@ -1026,35 +1026,35 @@ 1026 1026 ))) 1027 1027 1028 1028 ((( 1029 -Set Baud Rate: 1035 + 1036 + 1037 +* Set Baud Rate 1030 1030 ))) 1031 1031 1032 - 1033 1033 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1034 1034 1035 1035 1036 1036 ((( 1037 -Set UART Parity 1044 +* Set UART Parity 1038 1038 ))) 1039 1039 1040 - 1041 1041 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1042 1042 1043 1043 1044 1044 ((( 1045 -Set STOPBIT 1051 +* Set STOPBIT 1046 1046 ))) 1047 1047 1048 - 1049 1049 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1050 1050 1051 1051 1057 + 1052 1052 * ((( 1053 1053 (% style="color:#037691" %)** Downlink Payload:** 1054 1054 ))) 1055 1055 1056 1056 ((( 1057 -**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1063 +**A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1058 1058 ))) 1059 1059 1060 1060 ((( ... ... @@ -1069,11 +1069,11 @@ 1069 1069 ))) 1070 1070 1071 1071 ((( 1072 -A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1078 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1073 1073 ))) 1074 1074 1075 1075 ((( 1076 -A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1082 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1077 1077 ))) 1078 1078 1079 1079 ... ... @@ -1127,7 +1127,7 @@ 1127 1127 ))) 1128 1128 1129 1129 ((( 1130 -**Downlink Command:** 1136 +(% style="color:#037691" %)** Downlink Command:** 1131 1131 ))) 1132 1132 1133 1133 ((( ... ... @@ -1229,34 +1229,18 @@ 1229 1229 1230 1230 If device has not joined network yet: 1231 1231 1232 -(% class="box infomessage" %) 1233 -((( 1234 -**AT+FDR** 1235 -))) 1238 +* **(% style="color:#037691" %)AT+FDR** 1239 +* **(% style="color:#037691" %)AT+NJM=0** 1240 +* **(% style="color:#037691" %)ATZ** 1236 1236 1237 -(% class="box infomessage" %) 1238 -((( 1239 -**AT+NJM=0** 1240 -))) 1241 1241 1242 -(% class="box infomessage" %) 1243 1243 ((( 1244 -**ATZ** 1245 -))) 1246 - 1247 - 1248 -((( 1249 1249 If device already joined network: 1250 -))) 1251 1251 1252 -(% class="box infomessage" %) 1253 -((( 1254 -**AT+NJM=0** 1255 -))) 1246 +* **(% style="color:#037691" %)AT+NJM=0** 1247 +* **(% style="color:#037691" %)ATZ** 1256 1256 1257 -(% class="box infomessage" %) 1258 -((( 1259 -**ATZ** 1249 + 1260 1260 ))) 1261 1261 1262 1262 ... ... @@ -1401,6 +1401,10 @@ 1401 1401 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1402 1402 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1403 1403 1394 + 1395 + 1396 + 1397 + 1404 1404 = 9.Packing Info = 1405 1405 1406 1406 ... ... @@ -1417,6 +1417,10 @@ 1417 1417 * Package Size / pcs : 14.5 x 8 x 5 cm 1418 1418 * Weight / pcs : 170g 1419 1419 1414 + 1415 + 1416 + 1417 + 1420 1420 = 10. FCC Caution for RS485LN-US915 = 1421 1421 1422 1422 (((